全文获取类型
收费全文 | 36篇 |
免费 | 3篇 |
专业分类
儿科学 | 1篇 |
妇产科学 | 1篇 |
基础医学 | 5篇 |
口腔科学 | 7篇 |
临床医学 | 2篇 |
内科学 | 13篇 |
神经病学 | 1篇 |
外科学 | 1篇 |
综合类 | 2篇 |
预防医学 | 4篇 |
眼科学 | 1篇 |
中国医学 | 1篇 |
出版年
2024年 | 1篇 |
2023年 | 1篇 |
2022年 | 2篇 |
2020年 | 3篇 |
2019年 | 2篇 |
2018年 | 2篇 |
2017年 | 3篇 |
2014年 | 1篇 |
2013年 | 4篇 |
2011年 | 2篇 |
2010年 | 2篇 |
2009年 | 3篇 |
2008年 | 1篇 |
2007年 | 2篇 |
2006年 | 1篇 |
2005年 | 3篇 |
2004年 | 1篇 |
2002年 | 2篇 |
2001年 | 1篇 |
1999年 | 1篇 |
1978年 | 1篇 |
排序方式: 共有39条查询结果,搜索用时 46 毫秒
1.
Ayla Gunlemez Canan Baydemir Ayse Arisoy 《The journal of maternal-fetal & neonatal medicine》2019,32(14):2412-2417
Objective: Late-preterm delivery is known to be associated with potential adverse effects on lung development. Passive smoking may result in alterations of pulmonary function in infants born late-preterm. Impulse oscillometry (IOS) is a noninvasive, rapid, and practicable technique that can assess lung function. This study aimed to evaluate the effect of passive smoking on lung function tests in preschool children born late-preterm using IOS.Methods: The study population consisted of a total of 139 children between 3 and 7 years of age born late-preterm who were being followed-up at our outpatient unit at the time of study period. Late-preterms were subcategorized according to presence or absence of exposure to passive smoking (PS). Those with and without exposure to passive smoking were referred to as PS group (56.1%, n?=?78) and non-PS group (43.9%, n?=?61), respectively. Resistance (R5–R20), reactance (X5–X20), and resonant frequency were measured by impulse oscillometry (IOS) at 5–20?Hz.Results: Median R5-R20 and Z5 were significantly higher and median X10 was significantly lower in PS group compared to non-PS group (p?.05).Conclusions: This study demonstrated that passive smoking significantly increases peripheral airway resistance and seems to adversely affect lung function in children born late-preterm. 相似文献
2.
《Journal of prosthodontic research》2020,64(2):114-119
PurposeTo compare the precision of maxillo-mandibular registration and resulting full arch occlusion produced by three intraoral scanners in vitro.MethodsSix dental models (groups A–F) were scanned five times with intraoral scanners (CEREC, TRIOS, PLANMECA), producing both full arch and two buccal maxillo-mandibular scans. Total surface area of contact points (defined as regions within 0.1 mm and all mesh penetrations) was measured, and the distances between four pairs of key points were compared, each two in the posterior and anterior.ResultsTotal surface area of contact points varied significantly among scanners across all groups. CEREC produced the smallest contact surface areas (5.7–25.3 mm2), while PLANMECA tended to produce the largest areas in each group (22.2–60.2 mm2). Precision of scanners, as measured by the 95% CI range, varied from 0.1–0.9 mm for posterior key points. For anterior key points the 95% CI range was smaller, particularly when multiple posterior teeth were still present (0.04–0.42 mm). With progressive loss of posterior units (groups D–F), differences in the anterior occlusion among scanners became significant in five out of six groups (D–F left canines and D, F right canines, p < 0.05).ConclusionsMaxillo-mandibular registrations from three intraoral scanners created significantly different surface areas of occlusal contact. Posterior occlusions revealed lower precision for all scanners than anterior. CEREC tended towards incorrect posterior open bites, whilst TRIOS was most consistent in reproducing occluding units. 相似文献
3.
《Journal of prosthodontic research》2020,64(1):6-11
PurposeIntraoral scanners may offer an alternative to traditional impressions. That intraoral scanners produce precise scans is essential. Popular methods used to evaluate precision tend to rely on mean distance deviation between repeated scans. Mean value measurements may underestimate errors resulting in misleading conclusions and clinical decisions. This study investigated the precision of six intraoral scanners using the traditional method of measuring mean error, and a proposed method considering only the most extreme and clinically relevant aspects of a scan.MethodsAn edentulous model was scanned five times using six intraoral scanners. The repeated scans were aligned, uniformly trimmed and mean surface deviation measured across all 20 scan combinations within each scanner group. All scan combinations were then measured by arranging scan vertices from greatest to smallest unsigned distance from its compared scan and measuring the median value within the 1% of most greatly deviating points. Traditional mean deviation results and upper-bound deviations were compared.ResultsThe upper-bound deviation within a scan reported errors up to two times greater than those found when measuring global mean distances. Results revealed clinically relevant errors of more than 0.3 mm in scans produced by the Planmeca and Dentalwings scanners, findings not seen when measuring mean distance error of the complete scan.ConclusionsUpper-bound deviation of a cropped scan may provide a clinically useful metric for scanner precision. The Aadva, 3Shape, CEREC and TDS produced scans potentially appropriate for clinical use while Planmeca and Dentalwings produced deviations greater than 0.3 mm when measuring the upper-bound deviation. 相似文献
4.
《Journal of the American Dental Association (1939)》2014,145(11):1133-1140
Background.Little is known about the accuracy of physical dental casts that are based on three-dimensional (3D) data from an intraoral scanner (IOS). Thus, the authors conducted a study to evaluate the accuracy of full-arch stereolithographic (SLA) and milled casts obtained from scans of three IOSs.Methods.The authors digitized a polyurethane model using a laboratory reference scanner and three IOSs. They sent the scans (n = five scans per IOS) to the manufacturers to produce five physical dental casts and scanned the casts with the reference scanner. Using 3D evaluation software, the authors superimposed the data sets and compared them.Results.The mean trueness values of Lava Chairside Oral Scanner C.O.S. (3M ESPE, St. Paul, Minn.), CEREC AC with Bluecam (Sirona, Bensheim, Germany) and iTero (Align Technology, San Jose, Calif.) casts were 67.50 micrometers (95 percent confidence interval [CI], 63.43-71.56), 75.80 μm (95 percent CI, 71.74-79.87) and 98.23 μm (95 percent CI, 94.17-102.30), respectively, with a statistically significant difference among all of the scanners (P < .05). The mean precision values were 13.77 μm (95 percent CI, 2.76-24.79), 21.62 μm (95 percent CI, 10.60-32.63) and 48.83 μm (95 percent CI, 37.82-59.85), respectively, with statistically significant differences between CEREC AC with Bluecam and iTero casts, as well as between Lava Chairside Oral Scanner C.O.S. and iTero casts (P < .05).Conclusion.All of the casts showed an acceptable level of accuracy; however, the SLA-based casts (CEREC AC with Bluecam and Lava Chairside Oral Scanner C.O.S.) seemed to be more accurate than milled casts (iTero).Practical Implications.On the basis of the results of this investigation, the authors suggested that SLA technology was superior for the fabrication of dental casts. Nevertheless, all of the investigated casts showed clinically acceptable accuracy. Clinicians should keep in mind that the highest deviations might occur in the distal areas of the casts. 相似文献
5.
6.
目的: 探讨支原体感染患儿肺功能在治疗期、治疗后改变情况是否与哮喘患儿急性期与恢复期肺功能相似。方法: 对血清检测MP-IgM阳性的病人, 分别进行治疗期、治疗后IOS气道阻力测定, 并分析其变化, 同时测定哮喘发作期及恢复期IOS肺功能。结果: 支原体感染患儿在感染期IOS气道阻力的总阻抗(Zrs), 周边阻力(R5-R20) 均有不同程度增高与哮喘患儿极度相似(P>0. 05), 肺顺应性(X5), 在肺部感染严重情况下可降低, 一般在正常范围。结论: 支原体感染后主要引起小气道阻力增高, 所发生的病理改变与哮喘发作期非常相近, 是否发展为哮喘, 应定期随访。 相似文献
7.
In a variety of biomedical applications, particularly those involving screening for infectious diseases, testing individuals (e.g. blood/urine samples, etc.) in pools has become a standard method of data collection. This experimental design, known as group testing (or pooled testing), can provide a large reduction in testing costs and can offer nearly the same precision as individual testing. To account for covariate information on individual subjects, regression models for group testing data have been proposed recently. However, there are currently no tools available to check the adequacy of these models. In this paper, we present various global goodness‐of‐fit tests for regression models with group testing data. We use simulation to examine the small‐sample size and power properties of the tests for different pool composition strategies. We illustrate our methods using two infectious disease data sets, one from an HIV study in Kenya and one from the Infertility Prevention Project. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
8.
The strategies used by the macaca monkey brain in controlling the performance of a reaching movement to a visual target have been studied by the quantitative autoradiographic 14C-DG method.Experiments on visually intact monkeys reaching to a visual target indicate that V1 and V2 convey visuomotor information to the cortex of the superior temporal and parietoccipital sulci which may encode the position of the moving forelimb, and to the cortex in the ventral part and lateral bank of the intraparietal sulcus which may encode the location of the visual target. The involvement of the medial bank of the intraparietal sulcus in proprioceptive guidance of movement is also suggested on the basis of the parallel metabolic effects estimated in this region and in the forelimb representations of the primary somatosensory and motor cortices. The network including the inferior postarcuate skeletomotor and prearcuate oculomotor cortical fields and the caudal periprincipal area 46 may participate in sensory-to-motor and oculomotor-to-skeletomotor transformations, in parallel with the medial and lateral intraparietal cortices.Experiments on split brain monkeys reaching to visual targets revealed that reaching is always controlled by the hemisphere contralateral to the moving forelimb whether it is visually intact or ‘blind'. Two supplementary mechanisms compensate for the ‘blindness' of the hemisphere controlling the moving forelimb. First, the information about the location of the target is derived from head and eye movements and is sent to the ‘blind' hemisphere via inferior parietal cortical areas, while the information about the forelimb position is derived from proprioceptive mechanisms and is sent via the somatosensory and superior parietal cortices. Second, the cerebellar hemispheric extensions of vermian lobules V, VI and VIII, ipsilateral to the moving forelimb, combine visual and oculomotor information about the target position, relayed by the ‘seeing' cerebral hemisphere, with sensorimotor information concerning cortical intended and peripheral actual movements of the forelimb, and then send this integrated information back to the motor cortex of the ‘blind' hemisphere, thus enabling it to guide the contralateral forelimb to the target. 相似文献
9.
The association of nasal patency with small airway resistance in children with allergic and nonallergic rhinitis
下载免费PDF全文
![点击此处可从《The clinical respiratory journal》网站下载免费的PDF全文](/ch/ext_images/free.gif)
10.
Athavudh Deesomchok Warawut Chaiwong Chalerm Liwsrisakun Sirianong Namwongprom Chaicharn Pothirat 《Journal of thoracic disease》2022,14(5):1384
BackgroundThe ethnicity is significantly under-reported and this may limit the applicability of current impulse oscillometry (IOS) equations to heterogeneous patient populations. Establishing predictive equations for the IOS in the Thai adult population is still required. Therefore, this study aimed to establish reference equations for the IOS in the Thai adult population.MethodsThis retrospective cross-sectional study of IOS parameters in healthy adults aged greater than 20 years old with normal spirometry and who had no chronic respiratory diseases. Pre-bronchodilator (BD) IOS was performed in all subjects. Reference equations were calculated separately for men and women using multivariable linear regression analysis.ResultsA total of 127 subjects (87 men and 40 women) with a mean age of 48.7±17.2 (range, 22–92) years were included. The resistance at 5 Hz (R5), resistance at 20 Hz (R20), and area under reactance curve between 5 Hz and resonant frequency (AX) were significantly higher in women compared to men. The reference equations of the IOS parameters were established for men and women. Age, height, and bodyweight were shown to be the influential predictor as they contributed to the most of IOS indices except for the R5–R20 in men equations. Bodyweight was shown to be the influential predictor as it contributed to the most IOS indices except for the X5 in women’s equations.ConclusionsWe provided the reference equations for the IOS indices in Thai adults. IOS indices including R5, R20, and AX were significantly higher in women compared to men. 相似文献