首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   0篇
基础医学   1篇
内科学   25篇
外科学   1篇
综合类   1篇
药学   2篇
中国医学   1篇
  2023年   1篇
  2021年   1篇
  2019年   6篇
  2018年   10篇
  2016年   1篇
  2015年   1篇
  2014年   3篇
  2013年   3篇
  2010年   1篇
  2008年   1篇
  2006年   2篇
  2000年   1篇
排序方式: 共有31条查询结果,搜索用时 15 毫秒
1.

Objectives

The aim of this study was to investigate clinical outcomes after left main coronary artery (LM) bifurcation percutaneous coronary intervention (PCI) and the impact of the duration of dual antiplatelet therapy (DAPT) according to treatment strategy.

Background

There are limited data regarding the optimal PCI strategy for LM bifurcation lesions with new-generation drug-eluting stents.

Methods

A patient-level pooled analysis of 5 nationwide multicenter registries was performed. Rates of target lesion failure, thrombotic adverse cardiovascular events, and their individual components at 3-year were analyzed. Subgroup analysis according to DAPT duration was performed.

Results

From 13,172 patients undergoing PCI with new-generation drug-eluting stents, a total of 700 patients were treated for LM bifurcation lesions, 567 with a 1-stent strategy and 133 with a 2-stent strategy. Rates of target lesion failure and target lesion revascularization were higher in the 2-stent group, driven mainly by complex lesion profiles. Risks for thrombotic adverse cardiovascular events and its components were comparable between the 2 strategies. Subgroup analysis showed that risks for target lesion failure and thrombotic adverse cardiovascular events in the 2-stent group were significantly higher than in the 1-stent group in those with DAPT interruption <1 year, while they were similar in those receiving DAPT maintenance ≥1 year.

Conclusions

Up to 20% of patients who underwent LM bifurcation PCI eventually required a 2-stent strategy, which was as safe as a 1-stent strategy with the use of new-generation drug-eluting stents. Careful pre-emptive case selection as well as prolonged DAPT may be necessary when considering a 2-stent strategy in LM PCI given its higher rate of repeat revascularization and lesion failure than the 1-stent approach.  相似文献   
2.

Objectives

The authors sought to investigate the impact of diabetes mellitus (DM) on outcomes following contemporary drug-eluting stent (DES) implantation in the BIONICS (BioNIR Ridaforolimus Eluting Coronary Stent System in Coronary Stenosis) trial.

Background

Patients with DM are at increased risk for adverse events following percutaneous coronary intervention (PCI).

Methods

A prospective, multicenter, 1:1 randomized trial was conducted to evaluate in a noninferiority design the safety and efficacy of ridaforolimus-eluting stents versus zotarolimus-eluting stents among 1,919 patients undergoing PCI. Randomization was stratified to the presence of medically treated DM, and a pre-specified analysis compared outcomes according to the presence or absence of DM up to 2 years.

Results

The overall prevalence of DM was 29.1% (559 of 1,919). DM patients had higher body mass index, greater prevalence of hyperlipidemia and hypertension, and smaller reference vessel diameter. One-year target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) was significantly higher among diabetic patients (7.8% vs. 4.2%; p = 0.002), mainly due to higher target lesion revascularization (4.5% vs. 2.0%; p = 0.002). Rates of cardiac death, myocardial infarction, and stent thrombosis did not statistically vary. Among 158 patients undergoing 13-month angiographic follow-up, restenosis rates were 3 times higher in diabetic patients compared with nondiabetic patients (15.2% vs. 4.7%; p = 0.01). Clinical and angiographic outcomes were similar between ridaforolimus-eluting stent– and zotarolimus-eluting stent–treated patients.

Conclusions

Despite advances in interventional therapies, and the implementation of new-generation DES, diabetic patients still have worse angiographic and clinical outcomes compared with nondiabetic patients undergoing PCI.  相似文献   
3.
ObjectivesThe aim of this study was to investigate the hypothesis that a novel biodegradable polymer–coated, cobalt-chromium (CoCr), sirolimus-eluting stent (BP-SES) is noninferior in safety and efficacy outcomes compared with a durable polymer (DP)-SES.BackgroundNo randomized trials have the compared safety and efficacy of BP-SES versus DP-SES on similar CoCr platforms, thereby isolating the effect of the polymer type.MethodsIn this prospective, single-blind, randomized trial conducted at 32 Chinese sites, 2,737 patients eligible for coronary stenting were treated with BP- or DP-SES in a 2:1 ratio. The primary endpoint was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. Secondary endpoints included TLF components, and definite/probable stent thrombosis.ResultsAt 12 months, the difference in the primary endpoint of TLF between BP-SES (6.3%) and DP-SES (6.1%) groups was 0.25% (95% confidence interval: −1.67% to 2.17%, p for noninferiority = 0.0002), demonstrating noninferiority of BP-SES to DP-SES. Individual TLF components of cardiac death (0.7% vs. 0.6%, p = 0.62), target vessel myocardial infarction (3.6% vs. 4.3%, p = 0.39), and clinically indicated target lesion revascularization (2.6% vs. 2.2%, p = 0.50) were similar, as were low definite/probable stent thrombosis rates (0.4% vs. 0.6%, p = 0.55).ConclusionsIn this large-scale real-world trial, BP-SES was noninferior to DP-SES for 1-year TLF. (Evaluate Safety and Effectiveness of the Tivoli ® DES and the Firebird ® DES for Treatment of Coronary Revascularization; NCT01681381)  相似文献   
4.
ObjectivesThe purpose of this study was to investigate the differential clinical outcomes after percutaneous coronary intervention (PCI) for coronary bifurcation lesions with 1- or 2-stenting techniques using first- or second-generation drug-eluting stents (DES).BackgroundThe 2-stenting technique has been regarded to have worse clinical outcomes than the 1-stenting technique after bifurcation PCI with first-generation DES. However, there has been a paucity of data comparing the 1- and 2-stenting techniques with the use of second-generation DES.MethodsPatient-level pooled analysis was performed with 3,162 patients undergoing PCI using first- or second-generation DES for bifurcation lesions from the “Korean Bifurcation Pooled Cohorts” (COBIS [Coronary Bifurcation Stenting] II, EXCELLENT [Registry to Evaluate Efficacy of Xience/Promus Versus Cypher in Reducing Late Loss After Stenting], and RESOLUTE-Korea [Registry to Evaluate the Efficacy of Zotarolimus-Eluting Stent]). The 3-year clinical outcomes were compared between 1- and 2-stenting techniques, stratified by the type of DES.ResultsWith first-generation DES, rates of target lesion failure (TLF) or patient-oriented composite outcome (POCO) (a composite of all death, any myocardial infarction, any repeat revascularization, and cerebrovascular accidents) at 3 years were significantly higher after the 2-stenting than the 1-stenting technique (TLF 8.6% vs. 17.5%; p < 0.001; POCO 18.1% vs. 28.5%, p < 0.001). With second-generation DES, however, there was no difference between 1- and 2-stenting techniques (TLF 5.4% vs. 5.8%; p = 0.768; POCO 11.2% vs. 12.9%; p = 0.995). The differential effects of 2-stenting technique on the prognosis according to the type of DES were also corroborated with similar results by the inverse probability weighted model. The 2-stenting technique was a significant independent predictor of TLF in first-generation DES (hazard ratio: 2.046; 95% confidence interval: 1.114 to 3.759; p < 0.001), but not in second-generation DES (hazard ratio: 0.667; 95% confidence interval: 0.247 to 1.802; p = 0.425).ConclusionsPatient-level pooled analysis of 3,162 patients in Korean Bifurcation Pooled Cohorts demonstrated that the 2-stenting technique showed comparable outcomes to 1-stenting technique with second-generation DES, which is different from the results of first-generation DES favoring the 1-stenting technique.  相似文献   
5.
ObjectivesThis study examined the smoker’s paradox using patient-level data from 18 prospective, randomized trials of patients undergoing percutaneous coronary intervention (PCI) with stent implantation.BackgroundStudies on the effects of smoking and outcomes among patients undergoing PCI have reported conflicting results.MethodsData from the RAVEL, E-SIRIUS, SIRIUS, C-SIRIUS, TAXUS IV and V, ENDEAVOR II to IV, SPIRIT II to IV, HORIZONS-AMI, COMPARE I and II, PLATINUM, and TWENTE I and II randomized trials were pooled. Patients were stratified by smoking status at time of enrollment. The 1- and 5-year ischemic outcomes were compared.ResultsAmong 24,354 patients with available data on smoking status, 6,722 (27.6%) were current smokers. Smokers were younger and less likely to have diabetes mellitus; hypertension; hyperlipidemia; or prior myocardial infarction (MI), PCI, or coronary artery bypass grafting. Angiographically, smokers had longer lesions, more complex lesions, and more occlusions, but were less likely to have moderate or severe calcification or tortuosity. At 5 years, smokers had significantly higher rates of MI (7.8% vs. 5.6%; p < 0.0001) and definite or probable stent thrombosis (3.5% vs. 1.8%; p < 0.0001); however, there were no differences in the rates of death, cardiac death, target lesion revascularization, or composite endpoints (cardiac death, target vessel MI, or ischemic target lesion revascularization). After multivariable adjustment for potential confounders, smoking was a strong independent predictor of death (hazard ratio [HR]: 1.86; 95% confidence interval [CI]: 1.63 to 2.12; p < 0.0001), cardiac death (HR: 1.68; 95% CI: 1.38 to 2.05; p < 0.0001), MI (HR: 1.38; 95% CI: 1.20 to 1.58; p < 0.0001), stent thrombosis (HR: 1.60; 95% CI: 1.28 to 1.99; p < 0.0001), and target lesion failure (HR: 1.17; 95% CI: 1.05 to 1.30; p = 0.005).ConclusionsThe present large, patient-level, pooled analysis with 5-year follow-up clearly demonstrates smoking to be an important predictor of adverse outcomes after PCI.  相似文献   
6.

Objectives

The aim of this study was to evaluate 1-year clinical safety and efficacy of the dual-therapy COMBO stent in a large, all-comers patient-level pooled cohort.

Background

The COMBO stent (OrbusNeich Medical, Fort Lauderdale, Florida) is a novel stent with abluminal sirolimus elution from a biodegradable polymer and a luminal pro-healing anti-CD34+ antibody layer, which attracts circulating endothelial progenitor cells. These endothelial progenitor cells can quickly mature into normal endothelium, providing rapid endothelialization.

Methods

The MASCOT (Multinational Abluminal Sirolimus Coated biO-engineered stenT) (N = 2,614, 61 global sites) and REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coatED bio-Engineered StEnt Post Market Registry) (N = 1,000, 9 European sites) registries are 2 prospective, multicenter studies evaluating clinical outcomes after attempted COMBO stent placement in all-comer patients undergoing percutaneous coronary intervention. In this patient-level pooled analysis we analyzed 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Furthermore, we determined predictors of 1-year TLF.

Results

A total of 3,614 patients (63.5 ± 11.2 years of age; 23.8% women) were included in this analysis. The prevalence of diabetes mellitus was 29.3%, and 54.3% patients presented with acute coronary syndrome. The primary endpoint of 1-year TLF occurred in 140 (3.9%) patients, with incidence of cardiac death in 1.6%, target vessel myocardial infarction in 1.2%, clinically driven target lesion revascularization in 2.2%, and definite stent thrombosis in 0.5% patients. Insulin-treated diabetes mellitus, chronic renal failure, and American College of Cardiology/American Heart Association lesion type B2/C were independent predictors of 1-year TLF.

Conclusions

In this large patient-level pooled analysis of patients treated with the dual-therapy COMBO stent excellent results at 1-year were observed. (MASCOT - Post Marketing Registry [MASCOT]; NCT02183454; Prospective Registry to Assess the Long-term Safety and Performance of the COMBO Stent [REMEDEE Reg]; NCT01874002)  相似文献   
7.
ObjectivesThe present study aimed to investigate the difference in target lesion failure (TLF) at 3 years after double kissing (DK) crush stenting versus provisional stenting (PS) for unprotected left main distal bifurcation (UPLMb) lesions.BackgroundThe multicenter and randomized DKCRUSH-V (Double Kissing Crush versus Provisional Stenting for Left Main Distal Bifurcation Lesions: The DKCRUSH-V Randomized Trial) study showed fewer 1-year TLF after DK crush for UPLMb lesions compared with PS. The study reports the 3-year clinical outcome of the DKCRUSH-V study.MethodsA total of 482 patients with UPLMb lesions who were randomly assigned to either the DK crush group (DK group) or PS group in the DKCRUSH-V study were followed for 3 years. The primary endpoint was the occurrence of a TLF at 3 years. Stent thrombosis (ST) was the safety endpoint. Patients were classified by lesion’s complexity and NERS (New Risk Stratification) II or SYNTAX (Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery) score.ResultsAt 3 years, TLF occurred in 41 (16.9%) patients in the PS group and in 20 (8.3%) patients in the DK group (p = 0.005), mainly driven by increased target vessel myocardial infarction (5.8% vs. 1.7%; p = 0.017) and target lesion revascularization (10.3% vs. 5.0%; p = 0.029). Definite or probable ST rate at 3 years was 4.1% in the PS group and 0.4% in the DK group (p = 0.006). Notably, DK crush was associated with a significant reduction in both primary and secondary endpoints for patients with complex lesions or at high risk.ConclusionsProvisional stenting for UPLMb lesions was associated with significantly increased rates of TLF and ST over 3 years of follow-up. Further randomized study is warranted to confirm the benefits of DK crush stenting for complex UPLMb lesions. (Double Kissing and Double Crush versus Provisional T Stenting Technique for the Treatment of Unprotected Distal Left Main True Bifurcation Lesions: A Randomized, International, Multi-center Clinical Trial; ChiCTR-TRC-11001213).  相似文献   
8.

Objectives

The aim of this study was to compare the thin-strut biodegradable-polymer everolimus-eluting platinum-chromium stent (EES) with the biodegradable-polymer biolimus-eluting stainless-steel stent (BES).

Background

Currently available drug-eluting coronary stents have been refined to reduce the risk for coronary events following implantation.

Methods

This randomized, multicenter, all-comers, noninferiority trial was undertaken at 3 sites in western Denmark. Patients with clinical indications for percutaneous coronary intervention were eligible for inclusion. Patients were randomly assigned (1:1) to either EES or BES. The primary endpoint, target lesion failure, was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a nontarget lesion) and efficacy (target lesion revascularization) at 12 months, analyzed using intention-to-treat principles. The trial was powered to assess target lesion failure noninferiority of the EES compared with the BES with a predetermined noninferiority margin of 3%.

Results

A total of 1,385 patients were assigned to treatment with EES and 1,369 patients to treatment with BES. The analysis showed that 55 patients (4.0%) assigned to the EES and 60 (4.4%) assigned to the BES met the primary endpoint (absolute risk difference 0.4%; upper limit of 1-sided 95% confidence interval: 1.7%; p < 0.001).

Conclusions

At 1-year follow-up, the EES was found to be noninferior to the BES with respect to target lesion failure. (Everolimus-eluting SYNERGY Stent Versus Biolimus-Eluting Biomatrix NeoFlex Stent—SORT-OUT VIII; NCT02093845)  相似文献   
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏