首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   137篇
  免费   0篇
  国内免费   1篇
基础医学   1篇
口腔科学   2篇
临床医学   3篇
内科学   3篇
外科学   125篇
综合类   3篇
药学   1篇
  2022年   2篇
  2021年   9篇
  2020年   5篇
  2019年   9篇
  2018年   10篇
  2017年   16篇
  2016年   1篇
  2014年   16篇
  2013年   17篇
  2012年   10篇
  2011年   18篇
  2010年   5篇
  2009年   6篇
  2008年   5篇
  2007年   5篇
  2006年   2篇
  2004年   1篇
  2001年   1篇
排序方式: 共有138条查询结果,搜索用时 15 毫秒
1.
BackgroundMetal-on-metal (MOM) surfaces in total hip arthroplasty (THA) have been used widely. Serum cobalt and chromium levels have been the standard investigation for follow-up examinations, but magnetic resonance imaging (MRI) with metal artifact reducing sequences has shown good results in detecting pseudotumors. The aim of this study is to survey a significant correlation among MRI findings, serum metal levels, and clinical scores in patients with small-head MOM implants and if serum cobalt and chromium levels are sufficient in detecting patients with pseudotumors in the long-term follow-up.MethodsAt a minimum follow-up of 20 years, 26 patients (29 THAs) of the original 98 patients (105 THAs) included in this study between November 1992 and May 1994 were available for follow-up examination. Clinical scores, serum metal ion levels, and MRIs were obtained.ResultsWe found mean serum cobalt levels of 1.87 μg/L (±3.44) and chromium levels of 2.23 μg/L (±2.96) and very good clinical and functional results (mean Harris Hip Score 88.6) in the long-term follow-up. Pseudotumors were detected in MRIs of 21 hips. There were no significant differences between patients with or without pseudotumors regarding serum metal levels and the correlation for clinical outcome scores, demographic data, and cup inclination. The cumulative rate of survival was still at 91.4% at 22.8 years.ConclusionThis study presents the first published data on small-head MOM hips, comparing metal ion levels, pseudotumors, clinical, and radiological results in a follow-up period of more than 20 years and reveals that serum metal levels are not significantly higher in patients with pseudotumors.Level of EvidenceTherapeutic Level III  相似文献   
2.
《The Journal of arthroplasty》2019,34(7):1483-1491
BackgroundSurgeons currently have difficulty when managing metal-on-metal hip arthroplasty (MoMHA) patients with adverse reactions to metal debris (ARMD). This stems from a lack of evidence, which is emphasized by the variability in the recommendations proposed by different worldwide regulatory authorities for considering MoMHA revision surgery. We investigated predictors of poor outcomes following MoMHA revision surgery performed for ARMD to help inform the revision threshold and type of reconstruction.MethodsWe retrospectively studied 346 MoMHA revisions for ARMD performed at 2 European centers. Preoperative (metal ions/imaging) and intraoperative (findings, components removed/implanted) factors were used to predict poor outcomes. Poor outcomes were postoperative complications (including re-revision), 90-day mortality, and poor Oxford Hip Score.ResultsPoor outcomes occurred in 38.5%. Shorter time (under 4 years) to revision surgery was the only preoperative predictor of poor outcomes (odds ratio [OR] = 2.12, confidence interval [CI] = 1.00-4.46). Prerevision metal ions and imaging did not influence outcomes. Single-component revisions (vs all-component revisions) increased the risk of poor outcomes (OR = 2.99, CI = 1.50-5.97). Intraoperative modifiable factors reducing the risk of poor outcomes included the posterior approach (OR = 0.22, CI = 0.10-0.49), revision head sizes ≥36 mm (vs <36 mm: OR = 0.37, CI = 0.18-0.77), ceramic-on-polyethylene revision bearings (OR vs ceramic-on-ceramic = 0.30, CI = 0.14-0.66), and metal-on-polyethylene revision bearings (OR vs ceramic-on-ceramic = 0.37, CI = 0.17-0.83).ConclusionNo threshold exists for recommending revision in MoMHA patients with ARMD. However postrevision outcomes were surgeon modifiable. Optimal outcomes may be achieved if surgeons use the posterior approach, revise all MoMHA components, and use ≥36 mm ceramic-on-polyethylene or metal-on-polyethylene articulations.  相似文献   
3.
ObjectiveThis study was performed to assess the outcomes of Asian patients who underwent conversion from metal-on-metal total hip arthroplasty (MoM-THA) to cemented THA (CTHA).MethodsOne hundred and fifty-seven consecutive patients (157 hips) who underwent CTHA following primary MoM-THA from January 2005 to February 2015 were retrospectively analysed. The primary endpoints were the clinical outcomes. Follow-ups occurred at 3 months, 6 months, 1 year, 2 years, and then every 2 years following revision of MoM-THA.ResultsThe mean follow-up after conversion was 10 years (range, 5–14 years). Statistically significant improvements in the mean Harris hip score were observed between the preoperative and final follow-up evaluations (62.71 ± 13.85 vs. 84.03 ± 16.21, respectively). The major orthopaedic complication rate was 16.5% (26/157). Six (3.8%) patients underwent revision at a mean of 3.5 ± 1.3 years after conversion, predominantly because of prosthesis loosening or recurrent dislocation. Nine (5.7%) patients developed prosthesis loosening at a mean of 2.6 ± 1.1 years following conversion, two of whom requested revision surgery. Eleven (7.0%) patients developed prosthesis dislocation, four of whom requested revision surgery.ConclusionCTHA may yield favourable functional outcomes and a reduced rate of major orthopaedic complications.  相似文献   
4.
Metal-on-metal (MoM) bearings for total hip arthroplasty (THA) have come under scrutiny with reports of high failure rates. Clinical outcome studies with several commercially available MoM THA bearings remain unreported. We evaluated 78 consecutive MoM THAs from a single manufacturer in 68 patients. Sixty-six received cobalt–chrome (CoCr) monoblock and 12 received modular titanium acetabular cups with internal CoCr liners. Femoral components were titanium with modular necks. At average 2.1 years postoperatively, 12 THAs (15.4%) demonstrated aseptic failure (10 revisions, 2 revision recommended). All revised hips demonstrated capsular necrosis with positive histology reaction for aseptic lymphocytic vasculitis-associated lesions/adverse local tissue reactions. Prosthetic instability following revision surgery was relatively common. Female gender was a strong risk factor for failure, though smaller cups were not. Both monoblock and modular components fared poorly. Corrosion was frequently observed around the proximal and distal end of the modular femoral necks.  相似文献   
5.
ObjectiveTo compare the clinical outcomes of primary metal-on-metal total hip replacement (MoM-TR) converted to uncemented total hip replacement (UTR) or cemented total hip replacement (CTR) in patients with femoral neck fractures (AO/OTA: 31B/C).MethodsPatient data of 234 UTR or CTR revisions after primary MoM-TR failure from March 2007 to January 2018 were retrospectively identified. Clinical outcomes, including the Harris hip score (HHS) and key orthopaedic complications, were collected at 3, 6, and 12 months following conversion and every 12 months thereafter.ResultsThe mean follow-up was 84.12 (67–100) months for UTR and 84.23 (66–101) months for CTR. At the last follow-up, the HHS was better in the CTR- than UTR-treated patients. Noteworthy dissimilarities were correspondingly detected in the key orthopaedic complication rates (16.1% for CTR vs. 47.4% for UTR). Statistically significant differences in specific orthopaedic complications were also detected in the re-revision rate (10.3% for UTR vs. 2.5% for CTR), prosthesis loosening rate (16.3% for UTR vs. 5.9% for CTR), and periprosthetic fracture rate (12.0% for UTR vs. 4.2% for CTR).ConclusionIn the setting of revision of failed primary MoM-TR, CTR may demonstrate advantages over UTR in improving functional outcomes and reducing key orthopaedic complications.  相似文献   
6.
We report the case of a patient with leg edema after large-diameter metal-on-metal total hip arthroplasty. At 1 year and 2 months after primary left large-diameter metal-on-metal total hip arthroplasty, the patient complained of left leg edema. At first, we suspected deep venous thrombosis. However, deep venous thrombosis was not detected by venous ultrasonographic examination. Computed tomography imaging revealed a mass in front of the iliac fossa. The mass compressed the left iliac artery and vein. We therefore believed that this lesion was the cause of the leg edema and performed resection of the mass. The resected mass consisted of necrotic tissue infiltrating inflammation cells, so it was diagnosed as pseudotumor. Unilateral leg edema disappeared gradually after the resection.  相似文献   
7.
In recent years, metal-on-metal (MOM) arthroplasty has come under fire with reported adverse outcomes of metal hypersensitivity, adverse local tissue reaction (ALTR), and the carcinogenicity concern from systemic metal ions. We present a retrospective analysis of 354 primary total hip arthroplasties from 2 independent centers. Revision data, predicted survival and Harris Hip Scores (HHS) are reported. Nine hips (2.5%) underwent component revision, and 9 year predicted survival was 95.8%. One revision had elevated metal ions but no histological evidence of ALTR. Average HHS at a minimum 5 year follow up (range 5–10 years) improved significantly from 52 pre-operatively to 93 post-operatively. While a 2.5% revision rate and improved clinical outcomes are reported in this study, longer term follow-up is warranted to monitor for late complications.  相似文献   
8.
It has been suggested that corrosion and fretting at the tapered, modular junctions of hip arthroplasties may contribute to implant failure. In this study the reliability of a commonly used peer-reviewed scoring system for visual assessment of corrosion and fretting at these junctions was evaluated. Volumetric material loss at the tapered head surface was measured and associations with the visual scores were investigated. We found that the inter-observer reproducibility and single-observer repeatability of the corrosion scores were substantial using Cohen’s weighted Kappa statistic (k = 0.64–0.71). The reproducibility and repeatability of the fretting scores however were slight to fair (k = 0.18–0.31). Taper corrosion scores were significantly and moderately correlated with the volume of material loss measured (Spearman’s r = 0.59; P < 0.001). We recommend the continued use of this scoring system but it should not be a substitute for measurement of material loss.  相似文献   
9.
Size mismatch of components used in total hip arthroplasty is a serious, preventable patient safety incident of unknown prevalence as many cases are not detected. Component size mismatch was found in 11 cases (0.9%) at our retrieval centre. All cases of mismatch were not detected on plain radiograph during routine clinical follow up and blood metal ion levels were elevated above the MHRA action level of 7 ppb. Root cause analysis identified manufacturer, hospital and surgeon factors that need to be addressed to reduce the incidence of this avoidable clinical problem. Retrieval analysis is the only method of confirming size mismatch and is likely to be under-represented in National Joint Registries that record the indication for revision at the time of revision.  相似文献   
10.
The purpose of this prospective study was to evaluate the clinical and functional outcomes of THA using large-diameter metal-on-metal articulation in patients with neuromuscular weakness. Nineteen consecutive patients (19 hips) with neuromuscular weakness and displaced femoral neck fractures were enrolled. Functional improvement and recovery, radiological evaluation of THA and surgical morbidity were assessed. Mean Harris hip and WOMAC scores at final follow-up were 81.0 and 42.9, respectively. At final follow-up, no dislocation, metal hypersensitivity, or osteolysis was observed and no patient required revision of THA. The findings of this study indicate that the functional results of THA using large-diameter metal-on-metal articulation in patients with neuromuscular weakness can produce satisfactory outcomes with early functional recovery and a low dislocation rate.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号