首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   125篇
  免费   14篇
耳鼻咽喉   1篇
儿科学   3篇
基础医学   20篇
临床医学   18篇
内科学   14篇
神经病学   8篇
特种医学   42篇
外科学   3篇
综合类   2篇
预防医学   19篇
眼科学   1篇
药学   4篇
中国医学   2篇
肿瘤学   2篇
  2021年   2篇
  2020年   6篇
  2019年   7篇
  2018年   9篇
  2017年   3篇
  2016年   4篇
  2015年   2篇
  2014年   8篇
  2013年   12篇
  2012年   12篇
  2011年   8篇
  2010年   8篇
  2009年   7篇
  2008年   7篇
  2007年   6篇
  2006年   9篇
  2005年   3篇
  2004年   6篇
  2003年   3篇
  2002年   5篇
  2001年   6篇
  1999年   3篇
  1998年   1篇
  1994年   2篇
排序方式: 共有139条查询结果,搜索用时 15 毫秒
1.

Background

The purpose of this analysis is to describe the differences in cardiac magnetic resonance characteristics between benign and malignant tumors, which would be helpful for surgical planning.

Methods

This was a prospective cohort study of 130 patients who underwent cardiac magnetic resonance imaging for evaluation of a suspected cardiac mass. After excluding thrombi and tumors without definitive diagnosis, 66 tumors were evaluated for morphologic features and tissue composition.

Results

Of the 66 patients, 39 (59.0%) had malignant tumors and 27 (41.0%) had benign tumors. Patients with malignant tumors were younger when compared with those with benign tumors (age 51 years [42.8-60.0] vs 65 years [60.0-71.0] median). Malignant tumors more often demonstrated tumor invasion (69% vs 0% P < .001) and were more often associated with pericardial effusion (41% vs 7.4% P = .004). Presence of first-pass perfusion (100% vs 33% P < .001) and late gadolinium enhancement (100% vs 59.2%, P < .001) were significantly higher in malignant tumors. In logistic regression modeling, tumor invasion (P < .001) and first-pass perfusion (P < .001) were independently associated with malignancy. Furthermore, using classification and regression tree analysis, we developed a decision tree algorithm to help differentiate benign from malignant tumors (diagnostic accuracy ~90%). The algorithm-weighted cost of misclassifying a malignant tumor as benign was twice that of classifying a benign tumor as malignant.

Conclusions

Our study demonstrates that cardiac magnetic resonance imaging is a useful noninvasive method for differentiating malignant from benign cardiac tumors. Tumor size, invasion, and first-pass perfusion were useful imaging characteristics in differentiating benign from malignant tumors.  相似文献   
2.
To overcome specific absorption rate (SAR) limitations of spin-echo-based MR imaging techniques, especially at (ultra) high fields, rapid acquisition relaxation enhancement/TSE (turbo spin echo)/fast spin echo sequences in combination with constant or variable low flip angles such as hyperechoes and TRAPS (hyperTSE) have been introduced. Due to the multiple spin echo and stimulated echo pathways involved in the signal formation, the contrast behavior of such sequences depends on both T2 and T1 relaxation times. In this work, constant and various variable flip angle sequences were analyzed in a volunteer study. It is demonstrated that a single effective echo time parameter TE(eff) can be calculated that accurately describes the overall T2 weighted image contrast. TE(eff) can be determined by means of the extended phase graph concept and is practically independent of field strength. Using the described formalism, the contrast of any TSE sequence can be predicted. HyperTSE sequences are demonstrated to show a robust and well-defined T2 contrast allowing clinical routine MRI to be performed with SAR reductions of typically at least 70%.  相似文献   
3.
Human transmissible spongiform encephalopathies (TSE) encompass a group of rare neurodegenerative diseases. In April 2004, a group of international experts and regulators met in Buenos Aires, Argentina, to review the safety and to reach consensus on the use of urinary-derived gonadotrophins with respect to TSE. Iatrogenic transmission of Creutzfeldt-Jakob Disease (CJD) from pituitary-derived gonadotrophins has been reported, no infectivity in urine has been demonstrated, and no definite cases of transmission via urine have been reported. It is currently not possible to monitor donor urine or finished product for the presence of prions. Therefore the assessment of risk has to be based on the likelihood of infection in urine, the source of the urine, and the capacity of the manufacturing process to remove any adventitious infection. Urine for the production of medicinal products should be obtained from sources that minimize the possible presence of materials derived from subjects suffering from human TSE. As no strong evidence for TSE infectivity in urine exists, it can be concluded that the risk of disease-generating prions and TSE infectivity being present in donor urine is low. Current evidence indicates that, with respect to the risk of TSE infection, urinary-derived gonadotrophins appear to be safe.  相似文献   
4.
In this study, we present a new three‐dimensional (3D), diffusion‐prepared turbo spin echo sequence based on a stimulated‐echo read‐out (DPsti‐TSE) enabling high‐resolution and undistorted diffusion‐weighted imaging (DWI). A dephasing gradient in the diffusion preparation module and rephasing gradients in the turbo spin echo module create stimulated echoes, which prevent signal loss caused by eddy currents. Near to perfect agreement of apparent diffusion coefficient (ADC) values between DPsti‐TSE and diffusion‐weighted echo planar imaging (DW‐EPI) was demonstrated in both phantom transient signal experiments and phantom imaging experiments. High‐resolution and undistorted DPsti‐TSE was demonstrated in vivo in prostate and carotid vessel wall. 3D whole‐prostate DWI was achieved with four b values in only 6 min. Undistorted ADC maps of the prostate peripheral zone were obtained at low and high imaging resolutions with no change in mean ADC values [(1.60 ± 0.10) × 10?3 versus (1.60 ± 0.02) × 10?3 mm2/s]. High‐resolution 3D DWI of the carotid vessel wall was achieved in 12 min, with consistent ADC values [(1.40 ± 0.23) × 10?3 mm2/s] across different subjects, as well as slice locations through the imaging volume. This study shows that DPsti‐TSE can serve as a robust 3D diffusion‐weighted sequence and is an attractive alternative to the traditional two‐dimensional DW‐EPI approaches.  相似文献   
5.
Variant Creutzfeldt-Jakob disease (vCJD) has been reported in 12 countries. We hypothesized that a common strain of agent is responsible for all vCJD cases, regardless of geographic origin. To test this hypothesis, we inoculated strain-typing panels of wild-type mice with brain material from human vCJD case-patients from France, the Netherlands, Italy, and the United States. Mice were assessed for clinical disease, neuropathologic changes, and glycoform profile; results were compared with those for 2 reference vCJD cases from the United Kingdom. Transmission to mice occurred from each sample tested, and data were similar between non-UK and UK cases, with the exception of the ranking of mean clinical incubation times of mouse lines. These findings support the hypothesis that a single strain of infectious agent is responsible for all vCJD infections. However, differences in incubation times require further subpassage in mice to establish any true differences in strain properties between cases.  相似文献   
6.
The purpose of this work was to investigate the performance of the modified BIR‐4 T2 preparation for T2 mapping and propose a method to remove T2 quantification errors in the presence of large B1 and B0 offsets. The theoretical investigation of the magnetization evolution during the T2 preparation in the presence of B1 and B0 offsets showed deviations from a mono‐exponential T2 decay (two parameter fit). A three parameter fit was used to improve T2 accuracy. Furthermore, a two parameter fit with an additional saturation preparation scan was proposed to improve T2 accuracy and precision. These three fitting methods were compared based on simulations, phantom measurements and an in vivo healthy volunteer study of the neck musculature using a 3D TSE readout. The results based upon the pure two parameter fit overestimated T2 in regions with high B0 offsets (up to 40% in phantoms). The three parameter fit T2 values were robust to B0 offsets but with higher standard deviation (up to 40% in simulations). The two parameter fit with the saturation preparation yielded high robustness towards B0 offsets with a noise performance comparable to that of the two parameter fit. In the volunteer study the T2 values obtained by the pure two parameter fit showed a dependence on the field inhomogeneities, whereas the T2 values from the proposed fitting approach were shown to be insensitive to B0 offsets. The proposed method enabled accurate and precise T2 mapping in the presence of large B1 and B0 offsets.  相似文献   
7.
8.
9.
《Brachytherapy》2020,19(4):484-490
PurposeThe purpose of this study was to compare an isotropic three-dimensional (3D) T2-weighted sequence sampling perfection with application-optimized contrasts by using flip angle evolution (SPACE) with an axial two-dimensional T2-weighted turbo spin echo (TSE) sequence with regard to overall image quality and the delineation of normal prostate and periprostatic anatomy for low-dose-rate prostate cancer brachytherapy planning evaluation.Methods and MaterialsPatients (n = 69) with prostate cancer who had pelvic magnetic resonance imaging (MRI) for low-dose-rate brachytherapy treatment planning were included. Three radiologists independently assessed the visibility of nine anatomic structures on each sequence by using a 5-point scale and overall image quality by using a 4-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon signed rank test.ResultsNo significant intersequence differences were found for most (7/9) anatomical structures and overall image quality. The mean scores for visibility of anatomical structures on the 3D SPACE and 2D TSE sequences, respectively, were as follows: the zonal anatomy (3.7; 3.9, p = 0.05), prostate capsule (3.9; 4.0, p = 0.08), neurovascular bundle (2.9; 2.9, p = 0.9), rectoprostatic angle (3.8; 3.8, p = 0.35), rectum (4.2; 4.3, p = 0.26), urethra (3.8; 3.9, p = 0.12), urinary bladder (4.6; 4.6, p = 0.61), and overall image quality (2.9; 2.9, p = 0.33). 3D SPACE was superior for delineation of the genitourinary diaphragm (3.8; 3.6, p = 0.003), whereas 2D TSE was superior for delineation of the seminal vesicles (3.5; 4.0, p < 0.0001).ConclusionsAnatomic delineation of the prostatic and periprostatic anatomy provided by the 3D SPACE sequence is as robust in quality as that provided by a conventional 2D TSE sequence with superior delineation of the genitourinary diaphragm. For MRI-based brachytherapy treatment planning, the 3D SPACE sequence with subcentimeter isotropic resolution can replace the 2D TSE sequence and be incorporated into standard MRI protocols.  相似文献   
10.
Post-contrast three-dimensional T1-weighted imaging of the brain is widely used for a broad range of vascular, inflammatory or tumoral diseases. The variable flip angle 3D TSE sequence is now available from several manufacturers (CUBE, General Electric; SPACE, Siemens; VISTA/BRAINVIEW, Philips; isoFSE, Itachi; 3D MVOX, Canon). Compared to gradient-echo (GRE) techniques, 3D TSE offers the advantages of useful image contrasts and reduction of artifacts from static field inhomogeneity. However, the respective role of 3D TSE and GRE MR sequences remains to be elucidated, particularly in the setting of post-contrast imaging. The purpose of this review was (1) to describe the technical aspects of 3D TSE sequences, (2) to illustrate the main clinical applications of the post-contrast 3D T1-w TSE sequence through clinical cases, (3) to discuss the respective role of post-contrast 3D TSE and GRE imaging in the field of neuroimaging.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号