Sinus venosus atrial septal defect (SV‐ASD) usually coexists with partial anomalous pulmonary vein connection (PAPVC). It is a difficult diagnosis in transthoracic echocardiography (TTE) due to eccentric position of defects. We present a rare case of atypical anatomical variation in PAPVC, which was never described before. Two right pulmonary veins drained into superior vena cava, which overrode SV‐ASD and interatrial septum, a third pulmonary vein into the right atrium. Complete diagnosis could not be set after TTE, nor transesophageal echocardiography, whereas angio‐CT was finally conclusive. This diagnostic approach allowed the surgical planning. 相似文献
Introduction: Ocular dysfunctions and toxicities induced by antiepileptic drugs (AEDs) are rarely reviewed and not frequently received attention by treating physicians compared to other adverse effects (e.g. endocrinologic, cognitive and metabolic). However, some are frequent and progressive even in therapeutic concentrations or result in permanent blindness. Although some adverse effects are non-specific, others are related to the specific pharmacodynamics of the drug.
Areas covered: This review was written after detailed search in PubMed, EMBASE, ISI web, SciELO, Scopus, and Cochrane Central Register databases (from 1970 to 2019). It summarized the reported ophthalmologic adverse effects of the currently available AEDs; their risks and possible pathogenic mechanisms. They include ocular motility dysfunctions, retinopathy, maculopathy, glaucoma, myopia, optic neuropathy, and impaired retinal vascular autoregulation. In general, ophthalmo-neuro- or retino-toxic adverse effects of AEDs are classified as type A (dose-dependent), type B (host-dependent or idiosyncratic) or type C which is due to the cumulative effect from long-term use.
Expert opinion: Ocular adverse effects of AEDs are rarely reviewed although some are frequent or may result in permanent blindness. Increasing knowledge of their incidence and improving understanding of their risks and pathogenic mechanisms are crucial for monitoring, prevention, and management of patients’ at risk. 相似文献
??Objective To investigate the effect of tooth movement at different time after the repair of alveolar bone defects. Methods Defective alveolar bone model was established on one side in forty white rabbits??which were filled with bone meal and attached with Bio-Gide membrane as experiment sides. The other side was performed routine tooth extraction as control. Track the mandibular second molar in both sides respectively in 1 week??1 month??2 months and 3 months after operation. One month later??the distance between the mandibular second molar and third molar was measured with electronic vernier caliper in the experiment side and control side. The mandibular tissue was made paraffin section and hematoxylin eosin staining. Three views of the periodontal ligament in a third place of the mesial roots of the second molar was randomly chosen to count the total number of osteoclasts. Paired-t test analysis was made to evaluate the displacement of the mandibular second molar in experiment and control side??and to evaluate the number of osteoclasts in two side. Results In Group 1w and Group 1 m??the displacement of the mandibular second molar in experiment group was smaller than that in the control side??P??0.05??. There was no statistical significance in Group 2 m and Group 3 m. The number of osteoclasts in the experiment side was less than the control group in Group 1 w and Group1 m??P??0.05??. No statistical significance in Group 2 m and Group 3 m was found. Conclusion Orthodontic treatment can be performed two months after the repair of alveolar bone defects. 相似文献
Intramedullary nailing is considered a “gold standard” for treatment of tibial shaft fractures. However, some types of fractures are typically considered as “difficult for nailing”. This group includes the periarticular fractures, fractures of both bones at the same level, comminuted and segmental fractures of the tibia. Fixator-assisted nailing (FAN) is an effective method treatment of these types of fractures. The main requirements for the ideal reduction device are an ease of its installation and an ability of multiplanar fracture reduction. Fixator-assisted nailing (FAN) with the use of two perpendicular to each other monolateral tubular frames perfectly meets these requirements. In this study we present this new surgical technique and the analysis of first 30 cases.
Methods
A prospective analysis was conducted for 30 patients with “difficult for nailing” tibial fractures treated with fixator-assisted nailing in our institution between September 1st, 2017, and March 1st, 2018. The duration of surgery and its different stages, the time of fluoroscopy, difficulties encountered during surgery, were analyzed. Clinical and radiological methods were used to evaluated reduction quality.
Results
In all 30 cases the acceptable reduction was achieved. The mean duration of the surgical procedure was 73.7?±?3?min. The mean duration of fluoroscopy 85.9?±?4.8?s. In 7 cases we faced with technical difficulties, which were successfully addressed.
Conclusion
The described technique of FAN is an effective method for the treatment of “difficult for nailing” tibial fractures. Future multi-centered studies with a larger number of patients are needed to validate our results. 相似文献
Loss of function variants in NOTCH1 cause left ventricular outflow tract obstructive defects (LVOTO). However, the risk conferred by rare and noncoding variants in NOTCH1 for LVOTO remains largely uncharacterized. In a cohort of 49 families affected by hypoplastic left heart syndrome, a severe form of LVOTO, we discovered predicted loss of function NOTCH1 variants in 6% of individuals. Rare or low-frequency missense variants were found in 16% of families. To make a quantitative estimate of the genetic risk posed by variants in NOTCH1 for LVOTO, we studied associations of 400 coding and noncoding variants in NOTCH1 in 1,085 cases and 332,788 controls from the UK Biobank. Two rare intronic variants in strong linkage disequilibrium displayed significant association with risk for LVOTO amongst European-ancestry individuals. This result was replicated in an independent analysis of 210 cases and 68,762 controls of non-European and mixed ancestry. In conclusion, carrying rare predicted loss of function variants in NOTCH1 confer significant risk for LVOTO. In addition, the two intronic variants seem to be associated with an increased risk for these defects. Our approach demonstrates the utility of population-based data sets in quantifying the specific risk of individual variants for disease-related phenotypes. 相似文献
BACKGROUND: Repairing dorsal nasal defects is a frequent challenge for dermatologic surgeons, mainly due to the high frequency of basal cell carcinomas on this site. Obvious scars, mismatched skin and distortion of the nasal contour are the surgical hazards that must be avoided in these cases. AIM: Our aim was to perform surgery involving a simple flap in order to repair medium to large defects on the dorsal side of the nose. METHODS: The dorsal horizontal advancement flap was studied in 12 patients, in order to evaluate the benefits and limits of this surgical procedure. RESULTS: The resulting scars on most of our patients were well-camouflaged among their natural skin lines, and there was neither distortion of the alar contour nor the nostril. CONCLUSIONS: This flap is easy to perform and, in selected cases, provides an outstanding alternative to second-intention healing, full-thickness skin grafts, transposition, rotation and pedicle flaps. 相似文献
Facet joints play an important role in intervertebral load transmission and are crucial for rotational kinematics. Clinically, the role of facet joints as a possible source of low back pain is seen as controversial and at present is not sufficiently investigated. In this study, human lumbar facet (zygapopyhysial) joints from donors with advanced age were analyzed macroscopically, for degenerative changes. The aim was to determine the extent and morphology of degenerative changes in these joints. Lumbar facet joints (L1–L5) of 32 donors were studied (mean age 80.1±11.2 years). Joint capsules were carefully removed and joint surfaces (5 zones) examined using magnifying glasses and probes. In the result, the majority of facet joints showed cartilage defects of varying extent. Defects were located mostly at the margins of the articular surface, the central zone being relatively well preserved. Defect localization was different between superior (most cartilage defects in superior zone) and inferior (most defects inferiorly) facets. Further, defects were more severe caudal (level of L5) and in older persons. Osteophytes were present in up to 30%, located mostly at the latero-dorsal enthesis of the joint capsule on the superior facet. In conclusion, most margins of the articular facets are subject to degenerative changes in the lumbar spine of elderly persons, the topographical pattern being different in superior and inferior facets. This observation can be explained by the segmental motion patterns during extension/flexion movements of the facets. Sometimes, due to the marginal extension, it is obvious that not all changes can be assessed by CT or MRI. 相似文献