Background/objectiveObstructive sleep apnea (OSA) is independently associated with dyslipidemia, a surrogate marker of atherosclerosis. Low-density lipoprotein (LDL)-cholesterol is accepted as a major independent risk factor for cardiovascular disease. However, non-high-density lipoprotein (HDL)-cholesterol is a better marker of atherogenic dyslipidemia and recommended as a target of lipid lowering therapy. We aimed to assess the prevalence of atherogenic dyslipidemia, and relationship between OSA severity and serum LDL-cholesterol and non-HDL cholesterol levels in OSA patients.MethodsWe retrospectively evaluated treatment naïve 2361 subjects admitted to the sleep laboratory of a university hospital for polysomnography. All subjects’ lipid profile including total cholesterol, LDL-cholesterol, HDL-cholesterol, triglycerides, and non-HDL-cholesterol were measured.ResultsOut of 2361 patients (mean age 49.6 ± 11.9 years; 68.9% male, apnea-hypopnea index 36.6 ± 28.4/h), 185 (7.8%) had no OSA and 2176 (92.2%) had OSA. Atherogenic dyslipidemia prevalence was high (57–66%) in OSA patients, and especially increased in severe OSA compared to other groups (p < 0.05). Though total and LDL-cholesterol did not differ between those with and without OSA, non-HDL-cholesterol (p = 0.020), and triglycerides (p = 0.001) were higher and HDL-cholesterol levels (p = 0.018) were lower in OSA patients than non-OSA. Non-HDL-cholesterol was significantly correlated with OSA severity (p < 0.001) and hypoxia parameters (p < 0.01), whereas LDL-cholesterol showed no correlation.ConclusionsAtherogenic dyslipidemia is highly prevalent and non-HDL-cholesterol levels are significantly increased, predominantly in severe OSA patients. Non-HDL-cholesterol but not LDL-cholesterol, is significantly correlated with OSA severity and hypoxia parameters. Therefore, it could be better to use non-HDL-cholesterol, which is a guideline recommended target of lipid therapy, as a marker of atherosclerotic cardiovascular risk in OSA patients. 相似文献
Pulse oximetry is used widely to titrate oxygen therapy and for triage in patients who are critically ill. However, there are concerns regarding the accuracy of pulse oximetry in patients with COVID-19 pneumonitis and in patients who have a greater degree of skin pigmentation. We aimed to determine the impact of patient ethnicity on the accuracy of peripheral pulse oximetry in patients who were critically ill with COVID-19 pneumonitis by conducting a retrospective observational study comparing paired measurements of arterial oxygen saturation measured by co-oximetry on arterial blood gas analysis (SaO2) and the corresponding peripheral oxygenation saturation measured by pulse oximetry (SpO2). Bias was calculated as the mean difference between SaO2 and SpO2 measurements and limits of agreement were calculated as bias ±1.96 SD. Data from 194 patients (135 White ethnic origin, 34 Asian ethnic origin, 19 Black ethnic origin and 6 other ethnic origin) were analysed consisting of 6216 paired SaO2 and SpO2 measurements. Bias (limits of agreement) between SaO2 and SpO2 measurements was 0.05% (−2.21–2.30). Patient ethnicity did not alter this to a clinically significant degree: 0.28% (1.79–2.35), −0.33% (−2.47–2.35) and −0.75% (−3.47–1.97) for patients of White, Asian and Black ethnic origin, respectively. In patients with COVID-19 pneumonitis, SpO2 measurements showed a level of agreement with SaO2 values that was in line with previous work, and this was not affected by patient ethnicity. 相似文献
Women with pre-eclampsia have an increased risk of cardiovascular disease later in life. The aim of the study was to establish the presence and pattern of arterial stiffness in women previously with pre-eclampsia from a semi-rural region of South Africa. This was a prospective longitudinal study which involved 36 previously pre-eclamptic women and 86 non-pregnant controls (NPC) who had a past history of non-complicated pregnancy. Maternal wave reflection (augmentation index) and carotid-femoral pulse wave velocity were assessed noninvasively, using applanation tonometry with the SphygmoCor device. Endothelial function was assessed by EndoPAT 2000 device; pneumatic probes were fitted to the index fingers; induced flow-mediated reactive hyperemia; the ratio of the readings before and after occlusion was then used to calculate the score, the reactive hyperemia index (RHI) as a measure of endothelial function.
Pulse wave velocity remained significantly higher in previously pre-eclamptic women than non-pregnant controls up to three months after delivery (p < 0.05), then it reduced to nonsignificant values. All blood pressure indices (central and brachial pressures), were higher in previously pre-eclamptic women as compared to nonpregnant controls up to one year postpartum.
Regional (aortic) arterial stiffness, though it persists for some time after delivery, is transitory in previously pre-eclamptic women from the rural Africa setting. However, their increase blood pressure is an indication of compromised arterial compliance in women previously with pre-eclampsia. 相似文献
Background:Colon cancer is a common malignant tumor of the gastrointestinal tract. Therefore, a clear diagnosis is particularly important for the treatment of colon cancer. Ultrasound and spiral computed tomography (CT) can both be used in the diagnosis, but each has its own advantages and disadvantages, which could cause confusion in clinical choice. The purpose of this study was to systematically evaluate the practicability of spiral CT and ultrasound in the diagnosis of colon cancer.Methods:A systematic search was performed by retrieving on English databases (PubMed, Embase, Web of Science, the Cochrane Library) and Chinese databases (CNKI, Wanfang, Weipu [VIP], CBM). Besides, manually search for Google and Baidu academic of diagnostic experimental study of ultrasound and spiral CT in the diagnosis of Colon Cancer. The retrieval time limit was from the establishment of the database to October 2020. Two researchers independently extracted and evaluated the quality of the data in the included study. A meta-analysis was performed using Meta Disc1.4 and RevMan5.3 software.Results:Sensitivity, specificity, positive Likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were used to determine the diagnostic efficacy of ultrasonography and helical CT in colorectal cancer.Conclusions:This study will compare the practicability of CT and ultrasound in the diagnosis of colon cancer and provide reliable evidence-based basis for clinicians to choose the appropriate or best evidence-based basis.Ethics and dissemination:The private information from individuals will not be published. This systematic review also will not involve endangering participant rights. Ethical approval is not required. The results may be published in a peer-reviewed journal or disseminated in relevant conferences.OSF Registration number:DOI 10.17605/OSF.IO/WAJHQ 相似文献