Objective: To report a case of labour induction during extracorporeal membrane oxygenation (ECMO) support in a patient with acute respiratory distress syndrome (ARDS) caused by influenza and review of the literature.
Methods: Case report and the literature search of all English articles on delivery while on ECMO in patients with ARDS caused by influenza.
Results: A 25-year-old pregnant woman was initiated with ECMO due to severe ARDS caused by influenza A (H1N1) virus. When the patient had symptoms of colporrhagia and uterine contractions, the medical team decided to start labour induction while on ECMO. There were in total five case reports identified. Maternal oxygenation was improved after delivery and ECMO was successfully discontinued.
Conclusions: Maternal oxygenation was improved after delivery, which may be beneficial to reduce the duration of ECMO. Caesarean section (CS) may be the most used mode and labour induction could be another option. The procedure should be performed by an experienced ECMO team, cooperating with the obstetrician, anaesthesiologist, and ICU doctors. 相似文献
New electron paramagnetic resonance (EPR) oximetry probes were identified in the class of carbon black materials. These compounds exhibit very high oxygen sensitivity and favorable EPR characteristics for biological applications. At low pO(2), the linewidth is particularly sensitive to changes in oxygen tension (sensitivity of 750 mG/mmHg). The application of the probes for oximetry was demonstrated in vivo: the pO(2) was measured in muscle in which the blood flow was temporarily restricted as well as in tumor-bearing mice during a carbogen breathing challenge. The responsiveness to pO(2) was stable in muscle for at least 3 months. No toxicity was observed using these materials in cellular experiments and in histological studies performed 2, 7, and 28 days after implantation. In view of their EPR characteristics (high sensitivity) as well as the well-characterized production procedure that make them available on a large scale, these probes can be considered as very promising tools for future developments in EPR oximetry. 相似文献
Summary We report a case of a male patient suffering from a severe hemorrhagic radiation proctitis which gradually ceased with hyperbaric oxygen. We discuss the mechanisms of chronic radiation injury and the effect of the hyperbaric oxygen. This therapy is proposed as an alternative to surgical intervention for this abnormality. 相似文献
Abstract: Extracorporeal life support (ECLS or ECMO) is standard treatment for severe respiratory failure but poses many contraindications to future lung transplantation. The solution to this dilemma is the implantable gas exchange device (IGED) or artificial lung. Preliminary efforts to create such an artificial lung have been made since 1970 and include designs involving single devices, intravascular devices (i. e., IVOX), and combination heart–lung devices, Stringent requirements govern the design of such a device, the most important of which are high gas exchange efficiency, low resistance to blood flow, and size. This paper describes such a device. It incorporates large diameter inflow and outflow ports in close proximity and a low resistance wound hollow fiber core encapsulated in a compliant outer shell which conserves the work of the right ventricle. In a large animal model (adult sheep) this device was connected in line with the main pulmonary artery in series with the native lungs. This configuration has the advantages of using the lungs as an embolic filter, perfusing the lungs with fully oxygenated blood, and maintaining the integrity of the anatomy necessary for transplant. Laboratory experiments have run >8 h. Preliminary data show that the animals have remained hemodynamically stable while the devices have supported the animals completely by supplying 100% O2 saturation with PO2 values ranging from 250–350 mm Hg. Additionally, this model makes possible the study of respiratory failure without introducing other variables such as extracorporeal circuits or pumps. The other metabolic, endocrine, and reticuloendothelial functions of normal and injured lungs can now be studied more precisely by excluding these variables. Further studies are needed to evaluate this device in chronic (long–term implantation) experiments before clinical application. 相似文献
Summary Transcutaneous oxygen, laser Doppler flowmetry, peroneal nerve motor conduction velocity and skin temperature were assessed in both legs of 34 diabetic patients, who had a mean age of 41 (range 29–77) years, and diabetes duration of 21 (3–34) years. Transcutaneous oxygen significantly correlated with peroneal nerve motor conduction velocity (r=0.59 p<0.001) and laser Doppler flowmetry (r=0.7 p<0.001). Laser Doppler flowmetry correlated weakly with peroneal motor conduction velocity, (r=0.34 p<0.05). In each patient the leg with the higher transcutaneous oxygen (mean 70.2±9.3 (SD) mmHg) had a significantly higher peroneal motor conduction velocity (45.3±7.1 vs 41.5± 6.3 m/s, p<0.01), than the leg with the lower transcutaneous oxygen (61.0±11.9 mm Hg), though no difference in skin temperature was observed, 31.4±0.4 vs 31.1±0.5°C. We then assessed the potential for reversibility of conduction velocity deficits in ten non-diabetic patients, aged 59 (52–77) years, undergoing unilateral femoro-popliteal bypass, measuring transcutaneous oxygen, peroneal nerve motor conduction velocity and skin temperature pre- and 6 weeks post-surgery. In the control leg (unoperated) there was no significant change in transcutaneous oxygen (63.2±8.8 vs 63.0±4.6 mm Hg), peroneal nerve motor conduction velocity (45.1±7.8 vs 43.4±7.2 m/s) or skin temperature (30.8±1.3 vs 30.2±1.2°C) after surgery (all NS). In the operated leg, transcutaneous oxygen increased from 59.3±10.7 to 70.7±7.2 mm Hg (p<0.01), and peroneal nerve motor conduction velocity from 42.6±6.1 to 46.7±3.2 m/s (p<0.01), but skin temperature was unchanged 30.3±0.4 vs 30.4± 1.3°C (NS). These studies provide further evidence that peripheral nerve function is associated with tissue hypoxia and that improving tissue oxygenation can significantly improve nerve conduction over a short period of time. 相似文献
Objective : To define the individual neonatal response to the artificial surfactant, Exosurf, and factors that may influence the response. Methodology : Eighty-two consecutive, preterm neonates with respiratory distress syndrome, who received Exosurf at <12h of age were studied. Their response was categorized from the graphical change in the oxygenation index with postnatal age, for 12h after each of two doses of surfactant and assessed independently by two observers. Clinical factors were analysed for their effect on the four pre-defined categories of response, namely: none; mild; good; relapsed; and good: sustained. Results : Within the first 12h, 11% of the neonates showed no response, 5% a mild response and 84% a good response, but 34% relapsed. By 24h, 6% still showed no response (all died), 11% showed a mild response and 83% a good response, of whom half relapsed. At 24h, no response was significantly associated with low gestational age and asphyxia mild response with less severe lung disease. According to the response there was a gradation in the risk of death during the first week. Conclusions : The response to Exosurf can be individually and reproducibly categorized and demonstrated that 83% of neonates had a good response but half relapsed. No response was associated with extreme prematurity and asphyxia 相似文献