首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   188篇
  免费   27篇
  国内免费   4篇
儿科学   3篇
妇产科学   3篇
基础医学   4篇
临床医学   54篇
内科学   68篇
神经病学   15篇
特种医学   1篇
外科学   43篇
综合类   14篇
预防医学   2篇
药学   10篇
中国医学   2篇
  2023年   7篇
  2022年   8篇
  2021年   16篇
  2020年   23篇
  2019年   13篇
  2018年   14篇
  2017年   23篇
  2016年   15篇
  2015年   11篇
  2014年   17篇
  2013年   12篇
  2012年   5篇
  2011年   12篇
  2010年   7篇
  2009年   5篇
  2008年   2篇
  2007年   4篇
  2006年   5篇
  2005年   4篇
  2004年   1篇
  2003年   4篇
  2002年   1篇
  1999年   1篇
  1998年   1篇
  1997年   4篇
  1994年   1篇
  1992年   1篇
  1987年   2篇
排序方式: 共有219条查询结果,搜索用时 46 毫秒
1.
Platelet function has been described by many laboratory assays, and PL-11 is a new point-of-care platelet function analyzer based on platelet count drop method, which counts platelet before and after the addition of agonists in the citrated whole blood samples. The present study sought to compare PL-11 with other three major more established assays, light transmission aggregometry (LTA), VerifyNow? aspirin system and thromboelastography (TEG), for monitoring the short-term aspirin responses in healthy individuals. Ten healthy young men took 100?mg/d aspirin for 3-day treatment. Platelet function was measured via PL-11, LTA, VerifyNow and TEG, respectively. The blood samples were collected at baseline, 2 hour, 1 day during the aspirin treatment and 1 day, 5?±?1 days, 8?±?1 days after the aspirin withdrawal. Moreover, 90 additional healthy subjects were recruited to establish a reference range for PL-11. Platelet function of healthy subjects decreased significantly 2 hours after 100?mg/d aspirin intake and began to recover during 4–6 days after the aspirin withdrawal. Correlations between methods were PL-11 vs. LTA (r?=?0.614, p?<?0.01); PL-11 vs. VerifyNow (r?=?0.829, p?<?0.01); PL-11 vs. TEG (r?=?0.697, p?<?0.001). There was no significant bias between PL-11 and LTA at baseline (bias?=?1.94%, p?=?0.804) using Bland-Altman analysis, while the data of PL-11 were significantly higher than LTA (bias?=?24.02%, p?<?0.001) during the aspirin therapy. The reference range for PL-11 in healthy young individuals was from 66.8 to 90.5% (95%CI). When aspirin low-responsiveness was defined as LTA?>?20%, the cut-off values for each method were, respectively: PL-11?>?50%, VerifyNow?>?533 ARU, TEG?>?60.2%. The results of different platelet function assays were uninterchangeable for monitoring aspirin response and correlations among them were also varied. Correlations among PL-11 and other three major assays suggested the ability of PL-11 to assess the treatment effects of aspirin. But a large cohort study is needed to confirm the cut-off value of aspirin response detected by PL-11.  相似文献   
2.
BACKGROUND: Some cases of recurrent miscarriage have a thrombotic basis. Thromboelastography is a rapid, reproducible test of whole-blood haemostasis. METHODS: Thromboelastography was performed in 494 consecutive, non-pregnant women (median age 35 years; range 21-48) with a history of miscarriages at <12 weeks gestation (median 4; range 3-12) and 55 parous women (median age 33 years; range 20-41) with no history of pregnancy loss. The prospective outcome of untreated pregnancies amongst 108 women with recurrent miscarriage was studied. RESULTS: The maximum clot amplitude (MA) (median 66.0 mm; range 48.0-76.0) was significantly higher and the rate of clot lysis (LY30) (median 2.5%; range 0.5-7.8) significantly lower amongst women with recurrent miscarriage compared with controls (MA 61.5 mm; range 50.0-67.0; P = 0.01; LY30 4.9%; range 2.9-9.7; P = 0.01). The pre-pregnancy MA was significantly higher amongst women who subsequently miscarried (median 66.0 mm; range 54.0-73.0) compared with those whose had a live birth (median 61.7 mm; 48.0-71.5; P < 0.01). A pre-pregnancy MA >or=64 mm has a sensitivity of 68% and specificity of 82% to predict miscarriage. CONCLUSIONS: Thromboelastography identifies a subgroup of women with recurrent miscarriage to be in a prothrombotic state outside of pregnancy. Women in such a state are at increased risk of miscarriage in future untreated pregnancies.  相似文献   
3.
Objectives Prothrombin complex concentrates have been used to correct dilutional coagulopathy, but many preparations contain anticoagulants, such as heparin, to counteract their prothrombotic effects. These anticoagulants can interfere with haemostatic assays. The aim of this study was to monitor two different prothrombin complex concentrates for the treatment of albumin dilution in vitro, using rotational thromboelastometry with or without the heparin-antagonising agent protamine. Methods Citrated blood from 10 healthy volunteers was, in vitro, diluted 1:1 with 5% albumin and then corrected with a four-factor prothrombin complex concentrate with heparin anticoagulant (Confidex®) corresponding to a clinical dose of 43?IU/kg. Blood samples were tested with or without protamine. An activated prothrombin complex concentrate (APCC) (FEIBA®) without heparin in doses of 50?IU/kg and 100?IU/kg was also tested. Thromboelastometry was performed after recalcification. Results Albumin dilution significantly affected all thromboelastometry parameters. The four-factor PCC had an additional anticoagulant effect when added to the albumin-diluted blood; it was partially corrected by protamine for all parameters except maximum clot firmness. The APCC significantly improved all parameters, with over-correction of clotting time but only partial correction of maximum clot firmness. Conclusions The anticoagulant content of many prothrombin complex concentrates needs to be considered when performing in vitro testing. A heparin-free APCC better corrected an in vitro albumin-induced dilutional coagulopathy than a four-factor PCC, despite of blocking heparin with protamine.  相似文献   
4.
Summary. Laboratory evaluation of bleeding disorders has been performed with the standard clotting assays such as the PT and PTT for several decades. Our improved understanding of the process of blood coagulation has now revealed the important role played by the cellular elements such as platelets, monocytes and red blood cells. The need for a test that can assess clotting in a more ‘global’ manner, beyond the initiation of clot formation, has led to greater interest in assays such as thrombin generation and thromboelastography. Even though there are several publications using thromboelastography it remains a research tool as the methodology is not standardized. In an attempt to show reproducibility and consistency using thromboelastography, a group of investigators from different countries joined hands to form the TEG‐ROTEM Working Group. Two studies were performed using PRP and FVIII deficient plasma and an intrinsic pathway activator. This article summarizes the results of the first international effort at standardization of thromboelastography. Both of the instruments using this technology (TEG® and ROTEM®) were used. Nine laboratories from countries around the globe participated in this effort. The results showed a significant inter‐laboratory variance with CV’s greater than 10%. Although these results were not satisfactory, this has been the first effort to standardize this methodology and significant work remains to be done to improve reliability and reproducibility. These studies were performed on PRP and the results may be more reliable when preformed on whole blood samples. We believe that it is important to continue this work so that we may investigate the usefulness and potential applications of thromboelastography in the evaluation of bleeding and thrombosis.  相似文献   
5.
6.
7.
8.
Summary. Recombinant human FVIIa (rhFVIIa) corrects the coagulopathy in hemophilia A and B as well as FVII deficiency. This is also the case in dogs until canine anti‐human FVIIa antibodies develop (~2 weeks). Recombinant canine factor VIIa (rcFVIIa), successfully over‐expressed by gene transfer in haemophilia dogs, has provided long‐term haemostasis (>2 years). However, pharmacokinetics (PK), pharmacodynamics (PD) and safety of rcFVIIa after pharmacological administration have not been reported. We therefore wanted to explore the safety, PK and PD of rcFVIIa in dogs. A pilot study was set up to evaluate the safety as well as PK and PD of rcFVIIa after a single intravenous dose of 270 μg kg?1 to one HA and one haemostatically normal dog and to directly compare rcFVIIa with rhFVIIa in these two dogs. Single doses of rcFVIIa and rhFVIIa were well tolerated. No adverse events were observed. Pharmacokinetic characteristics including half‐life (FVIIa activity: 1.2–1.8 h; FVIIa antigen 2.8–3.7 h) and clearance were comparable for rcFVIIa and rhFVIIa. Kaolin‐activated thromboelastography approached normal in the HA dog with the improvement being most pronounced after rcFVIIa. This study provided the first evidence that administering rcFVIIa intravenously is feasible, safe, well tolerated and efficacious in correcting the haemophilic coagulopathy in canine HA and that rcFVIIa exhibits pharmacokinetic characteristics comparable to rhFVIIa in haemophilic and haemostatically competent dogs. This strengthens the hypothesis that rcFVIIa can be administered to dogs to mimic the administration of rhFVIIa to humans.  相似文献   
9.
Rationale:In coronavirus disease 2019 (COVID-19) patients with acute respiratory distress syndrome refractory to optimal conventional management, we should consider the indication for veno-venous extracorporeal membrane oxygenation (V-V ECMO). Growing evidence indicates that COVID-19 frequently causes coagulopathy, presenting as hypercoagulation and incidental thrombosis. For these reasons, a multifactorial approach with several anticoagulant markers should be considered in the management of anticoagulation using heparin in COVID-19 patients on V-V ECMO.Patient concerns:A 48-year-old man was infected with COVID-19 with a worsening condition manifesting as acute respiratory distress syndrome.Diagnoses:He was refractory to conventional therapy, thus we decided to introduce V-V ECMO. We used heparin as an anticoagulant therapy for V-V ECMO and adjusted the doses of heparin by careful monitoring of the activated clotting time (ACT) and activated partial thromboplastin time (APTT) to avoid both hemorrhagic and thrombotic complications. We controlled the doses of heparin in the therapeutic ranges of ACT and APTT, but clinical hemorrhaging and profound elevation of coagulant marker became apparent.Interventions:Using thromboelastography (TEG; Haemonetics) in addition to ACT and APTT, we were able to clearly detect not only sufficient coagulability of COVID19 on V-V ECMO (citrated rapid thromboelastography-R 0.5 min, angle 75.5°, MA 64.0 mm, citrated functional fibrinogen-MA 20.7 mm) but also an excessive effect of heparin (citrated kaolin -R 42.7 min, citrated kaolin with heparinase 11.7 min).Outcomes:Given the TEG findings indicating an excessive heparin effect, the early withdrawal of ECMO was considered. After an evaluation of the patient''s respiratory capacity, withdrawal from V-V ECMO was achieved and then anticoagulation was stopped. The hemorrhagic complications and elevated thrombotic marker levels dramatically decreased.Lessons:TEG monitoring might be a useful option for managing anticoagulation in COVID-19 patients on V-V ECMO frequently showing a hypercoagulative state and requiring massive doses of heparin, to reduce both hemorrhagic and thrombotic complications.  相似文献   
10.
BackgroundThromboelastography (TEG) provides global assessment of hemostatic function and has been recommended to monitor potential coagulopathies during pregnancy in which hypercoagulable state is favored. In present study, we established the reference intervals (RIs) of the TEG parameters (R, K, MA, and α‐angle) with Chinese pregnant women of third trimester. In addition, we examined the diagnostic efficacies of the TEG parameters in the patients diagnosed of gestational hypertension (GH), gestational diabetes mellitus (GDM), or preeclampsia (PE).MethodsWith specified including and excluding criteria, non‐pregnant controls, healthy pregnant women, and pregnant women with GH, GDM, or PE had their venous blood drawn at Beijing Obstetrics and Gynecology Hospital, followed by TEG tests performed in the clinical laboratory.ResultsThe RIs determined with the healthy pregnant women (in third trimester) for R, K, MA, and α‐angle were 4.0‐7.7, 1.2‐3.2, 51.9‐70.1, and 41.4‐74.4, respectively. When compared with the healthy pregnancy group, the K value was significantly decreased in GH patients but increased in PE patients; MA was significantly lower in the PE group. In the receiver operating characteristic curve (ROC) analyses, K value was able to efficiently distinguish normal pregnancy from the GH patients, with an AUC of 0.86 which is far better than those of R (AUC = 0.57) and MA (AUC = 0.56). For the PE patients, the AUC of MA (0.69) was significantly greater than that of R (0.50).ConclusionsThromboelastography may provide more accurate experimental basis for monitoring coagulation functions especially in pregnant women with complications of GH and PE.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号