10.
ObjectivesFasciculation potentials (FP) are an important consideration in the electrophysiological diagnosis of ALS. Muscle ultrasonography (MUS) has a higher sensitivity in detecting fasciculations than electromyography (EMG), while in some cases, it is unable to detect EMG-detected fasciculations. We aimed to investigate the differences of FP between the muscles with and without MUS-detected fasciculations (MUS-fas).
MethodsThirty-one consecutive patients with sporadic ALS were prospectively recruited and in those, both needle EMG and MUS were performed. Analyses of the amplitude, duration, and number of phases of EMG-detected FPs were performed for seven muscles per patient, and results were compared between the muscles with and without MUS-fas in the total cohort.
ResultsThe mean amplitude and phase number of FP were significantly lower in patients with EMG-detected FP alone (0.39 ± 0.25 mV and 3.21 ± 0.88, respectively) than in those with both FP and MUS-fas (1.22 ± 0.92 mV and 3.74 ± 1.39, respectively;
p < 0.0001 and
p = 0.017, Welch’s t-test).
ConclusionSmall FP may be undetectable with MUS. MUS cannot replace EMG in the diagnostic approach for ALS.
SignificanceClinicians should use a combination of EMG and MUS for the detection and quantitative analysis of fasciculation in ALS.