首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   105篇
  免费   1篇
基础医学   1篇
临床医学   5篇
内科学   89篇
特种医学   3篇
综合类   3篇
预防医学   3篇
药学   1篇
肿瘤学   1篇
  2023年   1篇
  2022年   2篇
  2021年   2篇
  2019年   7篇
  2018年   22篇
  2017年   1篇
  2016年   1篇
  2015年   10篇
  2014年   12篇
  2013年   16篇
  2012年   1篇
  2011年   7篇
  2009年   1篇
  2008年   3篇
  2007年   10篇
  2003年   3篇
  2001年   1篇
  1999年   2篇
  1996年   1篇
  1994年   1篇
  1992年   1篇
  1981年   1篇
排序方式: 共有106条查询结果,搜索用时 15 毫秒
1.
Children's growing use of the Internet creates both opportunities and risks. Collecting and comparing empirical findings on risks and opportunities experienced across 20 different European countries shows significant differences between them. Using Qualitative Comparative Analysis (QCA), this article investigates which factors contribute towards a high degree of online risk experienced by children across these countries. The research shows that patterns of similarities and differences do not seem to coincide with regional, political, and historical divides across European Union countries. The findings seem to endorse the multilayered approach of multi-stakeholder governance, which stresses the co-responsibility in securing children's online safety. However, one of the most important country conditions explaining high risk appears to be the lack of positive online content provision.  相似文献   
2.

Objectives

This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography.

Background

Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion.

Methods

This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis.

Results

The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial blood flow values to generate a myocardial perfusion reserve did not significantly increase the quantitative analysis area under the curve (p = 0.79).

Conclusions

Quantitative perfusion has a high diagnostic accuracy for detecting coronary artery disease but is not superior to visual analysis. The incorporation of rest perfusion imaging does not improve diagnostic accuracy in quantitative perfusion analysis.  相似文献   
3.
Bioresorbable vascular scaffolds (BRS) represent a novel approach to provide transient vessel support to drug-delivery capability without the long-term limitations of metallic drug-eluting stents (DES). The technology has the potential to overcome many of the safety concerns associated with metallic DES and possibly even convey further clinical benefit. In particular, the BRS are designed to provide short-term lumen support, and after being completely bioresorbed, eliminate the permanent caging typical of metallic DES. However, this technology has required new imaging modalities and methodologies for its assessment because the design, degradation rate, loss of mechanical property, and drug deliverability may affect its safety and efficacy. We provide an overview of all existing methods for assessing bioresorbable devices, from noninvasive to invasive, from light to sound based, and from morphological to functional parameters.  相似文献   
4.
ObjectivesThe aim of this study was to identify clinical, procedural, and angiographic correlates of late/very late drug-eluting stent (DES) thrombosis as well as to determine the clinical outcomes of these events.BackgroundLate/very late DES thromboses are a poorly studied phenomenon, partly due to the relative infrequency of these events, even in large cohort studies.MethodsIn the DESERT (International Drug-Eluting Stent Event Registry of Thrombosis), a retrospective, case-control registry, 492 cases of late/very late definite DES thrombosis from 21 international sites were matched in a 1:1 fashion with controls without stent thrombosis (ST). Controls were matched according to 2 criteria: same enrolling institution and date of initial DES implantation. Baseline and procedural variables were collected, and clinical follow-up was obtained for patients with ST as long as 1 year after the event. Offline quantitative coronary angiography was performed for a subset of 378 case-control pairs.ResultsThe majority of ST events occurred after 1 year (75%) and continued to occur for as long as 7.3 years. The clinical presentation of late/very late ST events was mainly myocardial infarction (66.7% ST-segment elevation myocardial infarction and 22.0% non–ST-segment elevation myocardial infarction); in-hospital mortality was 3.8%. A minority of patients (30%) with ST were receiving dual-antiplatelet therapy at the time of the event. Independent clinical correlates of late/very late ST were younger age, African-American race, current smoking, multivessel disease, longer stented length, overlapping stents, and percutaneous coronary intervention of vein graft lesions. Independent angiographic correlates for late/very late ST were lesions within the left anterior descending artery or a bypass graft, thrombus, and a larger residual diameter stenosis after the initial DES implantation. Despite the large sample of ST cases, all identified correlates of late/very late ST had weak associations with subsequent ST (all odds ratios <2.5).ConclusionsDespite a large sample of ST cases and use of limited matching to maximize the identification of predictive factors associated with late/very late ST, the variables associated with the development of late/very late ST were only weakly predictive of subsequent events. Additionally, a relatively low observed mortality rate of ST in this series may reflect a different pathophysiology of these late/very late events compared with acute/subacute ST. (Drug Eluting Stent Registry of Thrombosis [DESERT]; NCT00812552).  相似文献   
5.
6.

Objectives

To compare the outcomes of initial one-stent (1S) versus dedicated two-stent (2S) strategies in complex bifurcation percutaneous coronary intervention (PCI) using everolimus-eluting stents (EES).

Background

PCI of true bifurcation lesions is technically challenging and historically associated with reduced procedural success and increased restenosis. Prior studies comparing initial one-stent (1S) versus dedicated two-stent (2S) strategies using first-generation drug-eluting stents have shown no reduction in ischemic events and more complications with a 2S strategy.

Methods

We performed a retrospective study of 319 consecutive patients undergoing PCI at a single referral center with EES for true bifurcation lesions, defined by involvement of both the main vessel (MV) and side branch (SB). Baseline, procedural characteristics, quantitative coronary angiography and clinical outcomes in-hospital and at one year were compared for patients undergoing 1S (n = 175) and 2S (n = 144) strategies.

Results

Baseline characteristics were well-matched. 2S strategy was associated with greater SB acute gain (0.65 ± 0.41 mm vs. 1.11 ± 0.47 mm, p < 0.0001). In-hospital serious adverse events were similar (9% with 2S vs. 8% with 1S, p = 0.58). At one year, patients treated by 2S strategy had non-significantly lower rates of target vessel revascularization (5.8% vs. 7.4%, p = 0.31), myocardial infarction (7.8% vs. 12.2%, p = 0.31) and major adverse cardiovascular events (16.6% vs. 21.8%, p = 0.21).

Conclusion

In this study of patients undergoing PCI for true coronary bifurcation lesions using EES, 2S strategy was associated with superior SB angiographic outcomes without excess complications or ischemic events at one year.  相似文献   
7.
8.
9.
To assess the validity of locally performed off-line quantitative coronary angiography (QCA) measurement in clinical trials, we carried out a comparative study between on-site QCA analysis and analysis performed at an independent external core laboratory. One local operator analyzed the pre, post and follow-up angiograms of 116 patients participating in the Stenting in Small Coronary Arteries Study (SISCA) prior to final QCA analysis in the core laboratory. The mean values of the reference diameter (RD), minimal lumen diameter (MLD) and diameter stenosis (DS) showed acceptable agreement between study site and core laboratory. However, on the level of individuals the interobserver differences were large, affecting the outcome of restenosis rate significantly, and in a such way that the conclusions in the SISCA trial might have come out differently if a core laboratory had not been used. This emphasizes the importance of using independent core laboratories in coronary interventional trials.  相似文献   
10.

Objectives

The purpose of this study was to assess the diagnostic accuracy of coronary computed tomography angiography (CTA) for bioresorbable vascular scaffold (BVS) evaluation.

Background

Coronary CTA has emerged as a noninvasive method to evaluate patients with suspected or established coronary artery disease. The diagnostic accuracy of coronary CTA to evaluate angiographic outcomes after BVS implantation has not been well established.

Methods

In the ABSORB II (A Bioresorbable Everolimus-Eluting Scaffold Versus a Metallic Everolimus-Eluting Stent II) study, patients were randomized either to receive treatment with the BVS or everolimus-eluting metallic stent. At the 3-year follow-up, 238 patients (258 lesions) treated with BVS underwent coronary angiography with intravascular ultrasound (IVUS) evaluation and coronary CTA. The diagnostic accuracy of coronary CTA was assessed by the area under the receiver-operating characteristic curve with coronary angiography and IVUS as references.

Results

The mean difference in coronary CTA-derived minimal luminal diameter was ?0.14 mm (limits of agreement ?0.88 to 0.60) with quantitative coronary angiography as reference, whereas the mean difference in minimal lumen area was 0.73 mm2 (limits of agreement ?1.85 to 3.30) with IVUS as reference. The per-scaffold diagnostic accuracy of coronary CTA for detecting stenosis based on coronary angiography diameter stenosis of ≥50% revealed an area under the receiver-operating characteristic curve of 0.88 (95% confidence interval [CI]: 0.82 to 0.92) with a sensitivity of 80% (95% CI: 28% to 99%) and a specificity of 100% (95% CI: 98% to 100%), whereas diagnostic accuracy based on IVUS minimal lumen area ≤2.5 mm2 showed an area under the receiver-operating characteristic curve of 0.83 (95% CI: 0.77 to 0.88) with a sensitivity of 71% (95% CI: 44% to 90%) and a specificity of 82% (95% CI: 75% to 87%). The diagnostic accuracy of coronary CTA was similar to coronary angiography in its ability to identify patients with a significant lesion based on the IVUS criteria (p = 0.75).

Conclusions

Coronary CTA has good diagnostic accuracy to detect in-scaffold luminal obstruction and to assess luminal dimensions after BVS implantation. Coronary angiography and coronary CTA yielded similar diagnostic accuracy to identify the presence and severity of obstructive disease. Coronary CTA might become the method of choice for the evaluation of patients treated with BVS.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号