This is a Brighton Collaboration case definition of thrombosis and thromboembolism to be used in the evaluation of adverse events following immunization, and for epidemiologic studies for the assessment of background incidence or hypothesis testing. The case definition was developed by a group of experts convened by the Coalition for Epidemic Preparedness Innovations (CEPI) in the context of active development of SARS-CoV-2 vaccines. The case definition format of the Brighton Collaboration was followed to develop a consensus definition and defined levels of certainty, after an exhaustive review of the literature and expert consultation. The document underwent peer review by the Brighton Collaboration Network and by selected expert reviewers prior to submission. 相似文献
PurposeTo review and to compare indirectly the outcomes of minimally invasive therapies for the treatment of lower urinary tract symptoms secondary to benign prostatic hyperplasia.Materials and MethodsA literature search via Medline and Cochrane Central databases was completed for randomized control studies published between January 2000 to April 2020 for the following therapies: Rezum, Urolift, Aquablation, and prostatic artery embolization (PAE). Data on the following variables were included: International prostate symptom score (IPSS), maximum urinary flow rate, quality of life, and postvoid residual (PVR). Standard mean differences between treatments were compared through a meta-analysis using transurethral resection of the prostate (TURP) to assess differences in treatment effect.ResultsThere was no significant difference in outcomes between therapies for IPSS at the 3, 6, and 12-month follow ups. Although outcomes for Rezum were only available out to 3 months, there were no consistently significant differences in outcomes when comparing Aquablation versus PAE versus Rezum. TURP PVR was significantly better than Urolift at 3, 6, and 12 months. No significant differences in minor or major adverse events were noted.ConclusionAlthough significant differences in outcomes were limited, Aquablation and PAE were the most durable at 12 months. PAE has been well studied on multiple randomized control trials with minimal adverse events while Aquablation has limited high quality data and has been associated with bleeding-related complications. 相似文献
BackgroundCold snare polypectomy (CSP) is a promising technique for the removal of sessile serrated polyps (SSPs) ≥ 10 mm. However, the efficacy and safety of this technique remain undetermined.AimsWe aimed to comprehensively evaluate the efficacy and safety of CSP for SSPs ≥ 10 mm.MethodsPubMed, EMBASE, Web of Science and Cochrane Library were searched up to January 2021.ResultsA total of 10 studies consisting of 1727 SSPs (range, 10–40 mm) from 1021 patients were included. The overall rates of technical success, adverse events (AEs) and residual SSPs were 100%, 0.7% and 2.9%, respectively. Subgroup analysis showed that the rates of technical success and AEs were comparable between CSP and cold endoscopic mucosal resection (EMR) (99.9% vs. 100% and 1.3% vs. 0.5%, respectively), between the proximal and distal colon (100% vs. 99.9% and 0.3% vs. 0, respectively), and between polyps of 10–19 mm and ≥20 mm (99.8% vs. 100% and 0.9% vs. 0, respectively). However, subgroup analysis showed that the rate of residual SSPs was slightly lower in CSP compared with cold EMR (1.3% vs. 3.9%), as well as in polyps of 10–19 mm compared with those ≥20 mm (3.1% vs. 4.7%).ConclusionCSP was an effective and safe technique for removing SSPs ≥ 10 mm. 相似文献
Introduction: Immune checkpoint inhibitors (ICI) are now a standard of care in the treatment of many cancers leading to durable responses in patients with metastatic disease. These agents are generally well tolerated but may lead to the occurrence of immune-related adverse events (irAEs). As any organ may be affected, clinicians should be aware of the broad range of clinical manifestations and symptoms and keep in mind that toxicities may occur late, at any point along a patient’s treatment course. Although the most common irAEs are rarely severe, some of them may be associated with great morbidity and even become life-threatening. The rate of occurrence, type and severity of irAEs may vary with the type of ICI; thus, grade 3 and 4 irAEs are reported in more than 55% of patients treated with the combination of ipilimumab 3 mg/kg and nivolumab 1 mg/kg.
Area covered: This review presents the management of irAEs resulting from checkpoint blockade, with a focus on rare irAEs.
Expert commentary: With the development of immuno-oncology and the expanding role of ICI, physicians have learnt to diagnose and treat most of the irAEs that can occur. This review provides an overview of current guidelines, previously published studies and our multidisciplinary team based practices. 相似文献
Introduction: Pharmacovigilance is essential to monitoring the safety profiles of authorized medicines. Compared with small-molecule drugs, biological drugs are more complex, more susceptible to structural variability due to manufacturing processes, and have the potential to induce immune-related reactions, underscoring the importance of safety monitoring for these products. Although highly similar to reference products, biosimilars are not expected to be structurally identical. For these reasons, proper reporting of potential adverse drug reactions (ADRs) using distinguishable names and batch numbers is essential for accurate tracing of all biological drugs. To address the need for robust pharmacovigilance, the European Parliament and Council of the European Union provided legislation regarding pharmacovigilance of biologics in 2010.
Areas covered: This narrative review examines the current state of pharmacovigilance for biologics in the European Union (EU) and discusses relevant information on pharmacovigilance of biosimilars, the current EU pharmacovigilance system, and areas that could be improved.
Expert opinion: Although steps have been taken to improve pharmacovigilance of biologics in the EU, several enhancements can still be made, including additional training for healthcare professionals on ADR reporting, the use of 2D barcodes that enhance traceability, and an open discussion of potentially missed opportunities in the pharmacovigilance of biosimilars. 相似文献
BackgroundSafety signal detection in spontaneous reporting system databases and electronic healthcare records is key to detection of previously unknown adverse events following immunization. Various statistical methods for signal detection in these different datasources have been developed, however none are geared to the pediatric population and none specifically to vaccines. A reference set comprising pediatric vaccine-adverse event pairs is required for reliable performance testing of statistical methods within and across data sources.MethodsThe study was conducted within the context of the Global Research in Paediatrics (GRiP) project, as part of the seventh framework programme (FP7) of the European Commission. Criteria for the selection of vaccines considered in the reference set were routine and global use in the pediatric population. Adverse events were primarily selected based on importance. Outcome based systematic literature searches were performed for all identified vaccine-adverse event pairs and complemented by expert committee reports, evidence based decision support systems (e.g. Micromedex), and summaries of product characteristics. Classification into positive (PC) and negative control (NC) pairs was performed by two independent reviewers according to a pre-defined algorithm and discussed for consensus in case of disagreement.ResultsWe selected 13 vaccines and 14 adverse events to be included in the reference set. From a total of 182 vaccine-adverse event pairs, we classified 18 as PC, 113 as NC and 51 as unclassifiable. Most classifications (91) were based on literature review, 45 were based on expert committee reports, and for 46 vaccine-adverse event pairs, an underlying pathomechanism was not plausible classifying the association as NC.ConclusionA reference set of vaccine-adverse event pairs was developed. We propose its use for comparing signal detection methods and systems in the pediatric population. 相似文献