排序方式: 共有19条查询结果,搜索用时 15 毫秒
1.
Vishal Kapur MD Nathaniel R. Smilowitz MD Giora Weisz MD 《Catheterization and cardiovascular interventions》2014,83(6):915-921
A remote‐controlled, robotic system was developed to address procedural challenges and occupational hazards associated with traditional percutaneous coronary intervention (PCI). The PRECISE (Percutaneous Robotically Enhanced Coronary Intervention) Study demonstrated the safety and feasibility of the robotic system. We report four cases of complex coronary interventions demonstrating the capabilities of robotic‐enhanced PCI to treat multilesion, multivessel coronary disease, saphenous venous graft disease, and an ST‐elevation myocardial infarction. The robotic system offers enhanced visibility, precise measurement, accurate stent positioning, improved ergonomics, and superior operator protection from radiation. © 2013 Wiley Periodicals, Inc. 相似文献
2.
3.
Mamas A. Mamas PhD BM BCh Farzin Fath‐Ordoubadi MD BM BChir Douglas G. Fraser MD BM BChir 《Catheterization and cardiovascular interventions》2010,76(1):102-111
Failure to deliver stents is one of the commonest causes of procedural failure in contemporary PCI practice. We describe successful use of the Guideliner Catheter, the first purpose designed FDA and CE marked device delivery catheter in 13 complex cases in native coronary vessels and bypass grafts performed via the radial route to enable distal stent delivery following failure of conventional techniques. We discuss how the Guideliner catheter may be used to facilitate difficult radial cases. © 2010 Wiley‐Liss, Inc. 相似文献
4.
Pierfrancesco Agostoni Stefan Verheye 《Catheterization and cardiovascular interventions》2009,73(4):481-487
A 62‐year‐old man underwent percutaneous coronary intervention of a bifurcation lesion (Medina type 010) involving the mid‐left anterior descending coronary artery and an important first diagonal branch with a novel stent specifically designed for bifurcations, the Stentys coronary bifurcation system. This is a self‐expanding nitinol stent, with Z‐shaped struts linked by interconnections that can be disconnected (in prespecified points every 1.5 mm all around the circumference and the length of the stent) at the level of the ostium of the side branch, simply by inflating an angioplasty balloon tracked to the ostium of the side branch, through the stent struts. The steps required for deployment of the stent and the final result obtained were evaluated by intravascular ultrasound examination and StentBoost Subtract, a specific X‐ray stent‐enhancing visualization technique. © 2009 Wiley‐Liss, Inc. 相似文献
5.
6.
Rajesh Sachdeva MBBS FSCAI Barry F. Uretsky MD FSCAI 《Catheterization and cardiovascular interventions》2009,74(4):575-578
Percutaneous revascularization of chronically occluded coronary arteries remains technically challenging, with far lower procedural success rates compared to other lesion subsets. Retrograde approach via septal collateral is more promising for improving success rates of this lesion in native coronary arteries. The potential benefits of successful treatment results in improvement in angina and mortality are well established. Occluded saphenous vein graft recanalization retrogradely has not been described before. We describe a case of retrograde recanalization of chronically occluded saphenous vein graft. © 2009 Wiley‐Liss, Inc. 相似文献
7.
8.
Sayed M Abdou MD Chiung‐Jen Wu MD 《Catheterization and cardiovascular interventions》2011,77(6):785-789
The optimal technique for bifurcation stenting of distal Left main (LM) lesions remains unestablished and controversial. Some techniques with superior stent apposition, such as culotte technique were supposed to be associated with lower rate of stent thrombosis. However, with culotte technique, the double‐stent layer at the carina and in the proximal part of the bifurcation, may lead to difficult or improper rewiring of the side branch before final kissing balloon postdilatation (KBP). We describe a case of distal LM disease associated with distal left circumflex (LCX) and posterior descending artery stenosis. During LM stenting using culotte technique, improper rewiring of LCX before final KBP caused malapposition of the inner sent layer at the mid part of LM. Despite the optimal angiographic result, intravascular ultrasound (IVUS) was able to detect stent malapposition and guided further management to achieve complete stent apposition. The present case indicates that IVUS is an essential tool for LM stenting particularly when applying double stent strategy requiring final rewiring before KBP. Moreover, we suggest that some tools, such as Crusade and Venture catheters, can be used to ensure proper rewiring and hence, prevent subsequent stent malapposition, which may lead to catastrophic complications such as early and late LM stent thrombosis. © 2011 Wiley‐Liss, Inc. 相似文献
9.
Joel A Garcia S-Y James Chen John C Messenger Ivan P Casserly Adam Hansgen Onno Wink Babak Movassaghi Andrew J Klein John D Carroll 《Catheterization and cardiovascular interventions》2007,70(2):190-196
OBJECTIVE: Evaluate the safety of prolonged coronary injections during a rotational acquisition covering 180 degrees. BACKGROUND: Rotational angiography has been adapted to coronary angiography and shown to reduce radiation and contrast exposure. Three-dimensional (3D) reconstructions and other advanced applications require imaging over a 180 degrees -arc with a single but longer injection of larger contrast volumes. METHODS: Thirty patients referred for angiography were enrolled. Blood pressure (BP), heart rate (HR), symptoms, and ectopy were recorded before-and-after injections. RESULTS: Pre and post-injection HRs for the LCA/RCA were not statistically different (LCA-pre-injection 63+/-13 bpm vs. LCA-post-injection 62+/-11 bpm, P=0.54 and RCA-pre-injection 65+/-12 bpm vs. RCA-post-injection 65+/-10, P=0.88). Central aortic pressure values were not statistically different for the RCA injections (RCA-systolic-pre-injection 118+/-14 mm Hg vs. RCA-systolic-post-injection 112+/-25 mm Hg, P=0.15, and RCA diastolic-pre-injection 69+/-9 mm Hg vs. RCA-diastolic-post-injection 60+/-10 mm Hg, P=0.88) but were statistically significant for the LCA injections (LCA systolic-pre-injection 122+/-19 mm Hg vs. LCA-systolic-post-injection 116+/-17 mm Hg, P=0.0004, and LCA-diastolic-pre-injection 69+/-10 mm Hg vs. LCA-diastolic-post-injection 65+/-9 mm Hg, P=0.0007). There were no symptoms or electrical events documented during or immediately post-injection. CONCLUSION: This study demonstrates the feasibility and safety of longer coronary injections. There were no significant HR changes, clinically insignificant pressure changes, and no adverse reactions. Additional studies will be needed to assure its safety in a larger and clinically more varied patient population. 相似文献
10.
Timm Bauer MD Helge Möllmann MD Franz Weidinger MD Uwe Zeymer MD Ricardo Seabra‐Gomes MD Franz Eberli MD Patrick Serruys MD Alec Vahanian MD Sigmund Silber MD William Wijns MD Matthias Hochadel PhD Holger M. Nef MD Christian W. Hamm MD Jean Marco MD Anselm K. Gitt MD 《Catheterization and cardiovascular interventions》2011,78(5):702-709
Objectives : The present analysis was performed to evaluate the impact of diabetes mellitus (DM) status on the severity of coronary artery disease (CAD) and current approaches in interventional treatment. Background : Little is known about the effect of DM treated with diet, oral agents, or insulin on lesion characteristics and anatomical pattern of CAD and their interventional treatment. Methods and results : Patients (n = 46,779) of the contemporary Euro Heart Survey PCI registry with known DM status were included in this analysis. Nondiabetics (n = 35,280, 75.4%) were compared with diabetics treated with diet (n = 1,533, 3.3%), oral agents (n = 7,222, 15.4%), and insulin (n = 2,744, 5.8%). Diabetic patients were older, suffered more frequently from comorbidities and presented more often with cardiogenic shock. The number of severely stenosed (≥70%) segments incrementally increased from nondiabetics to insulin‐requiring diabetics. The location of lesions did not differ between patients with and without DM. The ratio stenosed/treated segments progressively rose among the four patient cohorts. The severity of DM negatively correlated with the extent of complete revascularization. After adjustment for confounding variables no significant differences in hospital mortality could be observed between patients without DM and diabetics treated with diet, but a significantly higher rate of death was seen in diabetic patients with oral medication and insulin therapy. Conclusions : Although CAD was more severe in patients with DM the percentage of treated segments with ≥70% stenosis was lower. Adjusted hospital mortality was increased among diabetics treated with oral medication or insulin, but not among those treated with diet. © 2011 Wiley‐Liss, Inc. 相似文献