PurposeThe purpose of this study was to determine whether computed tomography (CT)-based machine learning of radiomics features could help distinguish autoimmune pancreatitis (AIP) from pancreatic ductal adenocarcinoma (PDAC).Materials and MethodsEighty-nine patients with AIP (65 men, 24 women; mean age, 59.7 ± 13.9 [SD] years; range: 21–83 years) and 93 patients with PDAC (68 men, 25 women; mean age, 60.1 ± 12.3 [SD] years; range: 36–86 years) were retrospectively included. All patients had dedicated dual-phase pancreatic protocol CT between 2004 and 2018. Thin-slice images (0.75/0.5 mm thickness/increment) were compared with thick-slices images (3 or 5 mm thickness/increment). Pancreatic regions involved by PDAC or AIP (areas of enlargement, altered enhancement, effacement of pancreatic duct) as well as uninvolved parenchyma were segmented as three-dimensional volumes. Four hundred and thirty-one radiomics features were extracted and a random forest was used to distinguish AIP from PDAC. CT data of 60 AIP and 60 PDAC patients were used for training and those of 29 AIP and 33 PDAC independent patients were used for testing.ResultsThe pancreas was diffusely involved in 37 (37/89; 41.6%) patients with AIP and not diffusely in 52 (52/89; 58.4%) patients. Using machine learning, 95.2% (59/62; 95% confidence interval [CI]: 89.8–100%), 83.9% (52:67; 95% CI: 74.7–93.0%) and 77.4% (48/62; 95% CI: 67.0–87.8%) of the 62 test patients were correctly classified as either having PDAC or AIP with thin-slice venous phase, thin-slice arterial phase, and thick-slice venous phase CT, respectively. Three of the 29 patients with AIP (3/29; 10.3%) were incorrectly classified as having PDAC but all 33 patients with PDAC (33/33; 100%) were correctly classified with thin-slice venous phase with 89.7% sensitivity (26/29; 95% CI: 78.6–100%) and 100% specificity (33/33; 95% CI: 93–100%) for the diagnosis of AIP, 95.2% accuracy (59/62; 95% CI: 89.8–100%) and area under the curve of 0.975 (95% CI: 0.936–1.0).ConclusionsRadiomic features help differentiate AIP from PDAC with an overall accuracy of 95.2%. 相似文献
IntroductionAs an immune-mediated disease of the central nervous system, multifaceted aspects of a humoral immune response are widely described during multiple sclerosis (MS). However, the prevalence of different auto-antibodies, such as antinuclear antibodies (ANA), during MS is very variable and their clinical relevance remains controversial. Our aim was to evaluate the prevalence and clinical correlations of ANA positivity in South Tunisian MS patients.Material and methodsWe performed ANA screening using indirect immunofluorescence (IIF) on HEp-2 cells (Biosystems®) in 82 MS patients. For ANA positive samples (titer ≥1/160), anti-ds-DNA detection (IIF on Crithidia luciliae (Biosystems®)) and extractable nuclear antigen typing (immunodot (Euroimmun®)) were performed.ResultsANA were positive in 35/82 MS patients (42.7%). The titer was ≥ 1/320 in 16/35 patients. The antigenic specificity of ANA was identified in 7/35 patients. None of the patients had extra-neurological manifestations. No correlation was found between ANA and age, gender, MS course, disease duration, disability, annual relapse rate nor IgG index. ANA positivity was more frequent in patients with IgG oligoclonal bands (OCB) (47.1%) than in patients without IgG OCB (16,6%) (p = 0.049). Regarding disease activity, ANA positivity was significantly more frequent in patients with relapse (52.6%) than in patients in remission (25.9%) (p = 0.031).ConclusionOur results showed that ANA positivity in MS disease is not rare. This positivity was not associated with clinical expression of any connective tissue disease. ANA occurrence in MS was associated with IgG OCB+ profile and relapsing status, probably reflecting an ongoing immune dysregulation. 相似文献
Purpose: Spray-freeze drying (SFD) is a recently applied method to develop pharmaceutical powders. This study aimed to analyze the competence of Trehalose, Mannitol, Lactose, and Sorbitol instability and aerosolization of Immunoglobulin G (IgG) via SFD.
Methods: Induced soluble aggregates were quantified at 0 and 3?months, and 45?°C using size-exclusion chromatography. Conformation and thermogravimetric assessments were done by Fourier transform infrared spectroscopy and differential scanning calorimetry. Laser light scattering was performed to determine the particle sizes. Aerodynamic features were characterized by twin stage impinger and scanning electron microscopy.
Results: Although sugars/polyols preferably stabilized IgG following the process, storage stabilization was achieved in Trehalose, Trehalose-Lactose, Lactose, and Trehalose-Mannitol-based powders with soluble aggregates <5%. The conformation of antibody was preserved with β sheet content from 66.28% to 76.37%. Particle sizes ranged from 5.23 to 8.12?µm. Mannitol exhibited the best aerodynamic behavior, fine particle fraction (FPF: 70%) but high degree of protein aggregation during storage.
Conclusions: SFD could favorably stabilize antibody using Trehalose and its combination with Lactose and Mannitol, and also, Lactose alone. Sorbitol disturbed IgG powder recovery. Incorporation of other types of excipient is required for efficient respiratory delivery of IgG molecules. 相似文献
Chronic spontaneous urticaria (CSU) pathogenesis shows a complex and still unclear interplay between immunoglobulin (Ig)G- and IgE-mediated autoimmunity, leading to mast cell and basophil degranulation and wheal formation. The objective of this study was to evaluate at the same time IgE- and IgG-reactivity to well recognized and recently reported autoantigens in CSU patients, and to assess the effects of such reactivity on response to the anti-IgE monoclonal antibody omalizumab. Twenty CSU patients underwent omalizumab treatment. Urticaria activity score 7 (UAS7) was recorded at baseline and at different drug administration time-points for categorizing early-, late- or non-responders. At baseline, sera from the 20 patients and from 20 controls were tested for IgE and IgG autoantibodies to high- and low-affinity IgE receptors (FcεRI and FcεRII), tissue factor (TF) and thyroglobulin (TG) by immunoenzymatic methods. Antibody levels were compared with those of controls and analysed according to response. Eighteen patients were omalizumab responders (11 early and seven late), while two were non-responders. More than 50% of patients had contemporary IgE and IgG to at least to one of the four different autoantigens. Late responders showed higher levels of both anti-TF IgE and IgG than early responders (P = 0·011 and P = 0·035, respectively). Twenty-five per cent of patients had levels of anti-FcεRI IgE, exceeding the upper normal limit, suggesting that it could be a novel auto-allergen in CSU. In CSU, there is an autoimmune milieu characterized by the co-existence of IgE and IgG autoantibodies to the same antigen/allergen, particularly in late responders to omalizumab, possibly explaining the slower response. 相似文献
Staphylococcus aureus sepsis developed in a 14 year old girl. Immunological evaluation revealed low level of IgG3, although total IgG level was normal. The level of IgG3 increased gradually along with the recovery from sepsis. Immunoglobulin replacement therapy might have been useful in this patient, even though the total immunoglobulin level was within normal limits. 相似文献
We have devised assays to detect both circulating alloantibodies to platelets (indirect assay) and platelet-association IgG and IgM (direct assay) using a flow cytometric technique. A variety of patients with immune thrombocytopenia were studied. Employment of a confocal lens in the flow cytometer increased the discrimination power of the instrument. Patients with autoimmune thrombocytopenia (idiopathic thrombocytic purpura [ITP], systemic lupus erythematosus (SLE), lymphoma, leukemia, and drug-induced thrombocytopenia showed a significant increase in platelet-associated antibody. Circulating antibodies to platelets (alloantibodies) were demonstrated in cases of platelet refractoriness and neonatal isoimmune purpura. Day-today precision of the assays ranged from 3% to 6% (coefficient of variation). No interference was shown in the presence of hemoglobin (5 g/L), triglycerides (10 g/L), or polyclonal and monoclonal immunoglobulinemia (50 g/L: IgG, IgA, IgM). The sensitivity of the direct assay was 500 attograms of IgG or IgM platelet. 相似文献
Serum IgA and IgG functional antibodies and their subclasses to Streptococcus pneumoniae capsular antigen found in two aged‐matched cohorts of children with and without otitis media with effusion The relationship between acute otitis media and otitis media with effusion (OME) is uncertain and the aetiology of OME is multifactorial. Otitis media with effusion may be an inflammatory condition; both bacteria and viral infections could play a part in this inflammation. The four bacteria Streptococcus pneumoniae, Haemophilus influenza, Staphylococcus aureus and Branhamella catarrhalis cause 60% of the infections whereas S. pneumoniae accounts for up to 35%. IgA provides the dominant surface response to polysaccharide and lipopolysaccharide antigens, of which IgA2 is the main subclass. Once the mucosa has been breached, most protection is provided by IgG. IgG2 acts mainly against bacterial capsular antigens. This study looked at two groups of 50 children with and without OME who were aged between 3 and 10 years. The aims were to determine if, firstly, the levels of the serum immunoglobulins were different in the two groups, secondly whether these children made the appropriate antibody response to the capsular antigen to S. pneumoniae (PCP), and finally if there was a delay in the maturity of the IgA response. The total IgG, IgA and all subclass levels were measured using radial immunodiffusion. Levels of functional IgA and IgG were measured using ELISAs (25 patients in each group). The results were analysed with non‐parametric tests. The immunoglobulin levels were within the normal levels for both groups. There were very good correlations between the IgG total anti‐PCP and the IgG2 anti‐PCP (R > 0.9, p = 0.001). There was a good correlation between the levels of both IgG total and IgG2 anti‐PCP against IgA total anti‐PCP in both groups (R > 0.85, p > 0.01). This confirms a normal antibody response between both groups of patients. The ages of the controls and patients (50 samples) were correlated with increasing titres of circulating functional antibodies (P = 0.001). This is highly suggestive of a normal age‐related response. In conclusion, the findings were contradictory to our original hypothesis that there is a subtle difference in surface protection between children with and without OME. We believe that a previous history of recurrent acute otitis media is unrelated to the development of OME after 3 years of age. 相似文献