首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   2篇
基础医学   12篇
临床医学   3篇
内科学   5篇
皮肤病学   1篇
神经病学   3篇
特种医学   3篇
外科学   5篇
预防医学   2篇
  2023年   1篇
  2015年   3篇
  2014年   1篇
  2013年   3篇
  2012年   2篇
  2011年   1篇
  2010年   1篇
  2008年   2篇
  2007年   5篇
  2004年   4篇
  2003年   2篇
  1999年   1篇
  1997年   1篇
  1996年   1篇
  1994年   1篇
  1988年   1篇
  1986年   1篇
  1976年   2篇
  1970年   1篇
排序方式: 共有34条查询结果,搜索用时 31 毫秒
1.
2.

Objectives

Evaluation of enhancement characteristics of histopathologically confirmed focal nodular hyperplasias (FNHs) and hepatocellular adenomas (HCAs) with gadoxetic acid-enhanced MRI.

Methods

Sixty-eight patients with 115 histopathologically proven lesions (FNHs, n?=?44; HCAs, n?=?71) examined with gadoxetic acid-enhanced MRI were retrospectively enrolled (standard of reference: surgical resection, n?=?53 patients (lesions: FNHs, n?=?37; HCAs, n?=?53); biopsy, n?=?15 (lesions: FNHs, n?=?7; HCAs, n?=?18)). Two radiologists evaluated all MR images regarding morphological features as well as the vascular and hepatocyte-specific enhancement in consensus.

Results

For the hepatobiliary phase, relative enhancement of the lesions and lesion to liver enhancement were significantly lower for HCAs (mean, 48.7 (±48.4) % and 49.4 (±33.9) %) compared to FNHs (159.3 (±92.5) %; and 151.7 (±79) %; accuracy of 89 % and 90 %, respectively; P?<?0.001). Visual strong uptake of FNHs vs. hypointensity of HCAs in the hepatobiliary phase resulted in an accuracy of 92 %. This parameter was superior to all other morphological and dynamic vascular criteria alone and in combination (accuracy, 54–85 %).

Conclusions

For differentiation of FNHs and HCAs by means of MRI, gadoxetic acid uptake in the hepatobiliary phase was found to be superior to all other criteria alone and in combination.

Key Points

? EOB-MRI is well suited to differentiate FNHs and hepatocellular adenomas. ? For this purpose hepatobiliary phase is superior to unenhanced and dynamic imaging. ? Hepatobiliary phase (peripheral) hyper- or isointensity is typical for FNH. ? Hepatobiliary phase hypointensity is typical for hepatocellular adenomas. ? EOB-MRI helps to avoid misinterpretations of benign hepatocellular lesions.  相似文献   
3.
Zusammenfassung Untersuchungen der Gesamtleukocytenzahl, des Differentialblutbildes und der osmotischen Leukocytenresistenz wurden bei Patienten mit Lebererkrankungen, mit und ohne portale Hypertension, während einer Knochenmarksfunktionsprüfung mit Pyrexal® vorgenommen. Die Befunde sprechen für einen erhöhten Leukocytenumsatz bei den Patienten mit portaler Hypertonie und gegen eine entscheidende Ausschwemmungshemmung der Zellen aus dem Knochenmark durch die Milz. Der mangelnde Leukocytenanstieg während des Testes scheint nur Folge der rascheren Abfilterung der Zellen in der gestauten Milz und Pfortader zu sein.
Summary Numbers of leucocytes, differential blood count and osmotic resistance of leucocytes has been observed in patients with chronic liver diseases, with and without portal hypertension, during examination of bone marrow function with a lipopolysaccharide (Pyrexal®). The results give evidence for an augmented turnover of leucocytes and not for an inhibition of cell production in bone marrow by the spleen. The different total increase of leucocytes in patients with portal hypertension appears to be influenced by an increased white blood cell reservoir function of the congested spleen and portal vein.
  相似文献   
4.
Real-time PCR technology has improved molecular diagnostics of many pathogens, but no such test is available for Mycobacterium leprae. In this report we describe the establishment and the pre-clinical evaluation of such an assay. The test achieved a theoretical analytical sensitivity limit of 194 M. leprae cells per skin biopsy specimen and facilitated quantification of mycobacteria in tissue over a range of 54–54,000,000 cells per sample. In punch skin biopsies from 39 untreated Ugandan patients with newly diagnosed leprosy, the clinical diagnosis could be confirmed in 88.9% of multibacillary and 33.3% of paucibacillary (microscopically negative) patients. Real-time detection thus did not increase the clinical sensitivity of PCR as compared to conventional protocols, in spite of its evidently high analytical sensitivity. On the other hand, as still no culture system exists for M. leprae, the assay appears to be a robust tool for detection of the bacterium in selected clinical situations, as well as for quantitation in experimental settings.  相似文献   
5.
Abstract Herein, we describe a case of leprosy in a 29-year-old pregnant southeast-asian woman who presented with joint pain and multiple disseminated erythematous macules, papules and plaques. Histological examination and stains for acid-fast bacilli from skin biopsies substantiated the clinical suspicion of a cutaneous mycobacterial disease and both should be performed in all patients with unidentified skin lesions. The definitive laboratory diagnosis of leprosy was achieved by the application of a species-specific real-time polymerase chain reaction from infected tissue.  相似文献   
6.
7.
Zusammenfassung Wegen toxischer Dilatation und massiver Blutung des Colons bei Colitis ulcerosa mußte bei 17 von 44 Patientenunter Notfallbedingungen operiert werden. 8 Patienten verstarben innerhalb von durchschnittlich 10 Tagen an den Folgen der kotigen Peritonitis nach Colonperforation. Zur Verhütung dieser schweren Komplikationen gilt die Anlage einer doppelläufigen Ileostomie sowie einer Transversum- und Sigmadekompressionskolostomie nach Turnbull mit zweizeitiger Proktokolektomie nach 6 Monaten als Methode der Wahl.  相似文献   
8.
Real-time detection of methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-susceptible S. aureus (MSSA) in cases of clinical bacteremia may promote appropriate antimicrobial therapy and infection control. Expense inherent to molecular diagnostics may prevent laboratories from utilizing real-time PCR for this purpose. BD GeneOhm StaphSR assay master mix was reconstituted and aliquoted into SmartCycler tubes in 25-μl volumes (freshly reconstituted master mix), with a portion being frozen at −70°C (frozen master mix). Incubation of 40 previously analyzed lysates from positive BacT/Alert SA and SN blood culture bottles (identified as 10 MRSA strains, 10 MSSA strains, 12 coagulase-negative Staphylococcus strains, and 8 Micrococcus strains) in freshly reconstituted master mix and master mix frozen between 1 week and 6 months generated the expected results in all PCRs. Similarly, positive- and negative-control reagents stored frozen at −70°C for up to 18 weeks yielded the expected reactions. Prospective analysis of 244 positive blood culture samples utilizing 1-week-frozen master mix and freshly reconstituted master mix yielded a 1.2% discordant rate upon initial testing due to three unresolved results (two unresolved results for freshly reconstituted master mix and one unresolved result for frozen master mix). Repeat testing produced a final 100% concordance rate between the two master mix preparations. Use of master mix that was frozen up to 6 months did not compromise performance of the BD GeneOhm StaphSR assay. This modification, resulting in less reagent waste, may allow a greater number of laboratories to consider real-time PCR methodology for detection of bacteremia caused by MRSA and MSSA.Detection and proper identification of pathogens from the bloodstream are arguably two of the most important aims of diagnostic assays performed in the clinical microbiology laboratory. Estimates of the number of patients with bloodstream infections per year in the United States are commonly cited at 200,000 patients (17), with mortality rates approaching 30% (24). Staphylococcus aureus alone is responsible for approximately 20% of the cases of bloodstream infection (6, 24), and up to 57% of S. aureus isolates recovered from blood cultures demonstrate resistance to methicillin (7, 24). Methicillin-resistant S. aureus (MRSA) bloodstream infection not only generates additional financial and service burdens for health care facilities to a greater extent than those caused by methicillin-susceptible S. aureus (MSSA) (3, 18, 21), but it also demonstrates a significantly higher mortality rate (4, 18). Taken together, these data suggest that rapid identification and methicillin resistance profiling of S. aureus bloodstream infection may be of benefit to patients and allied health care professionals.While nucleic acid hybridization assays (10) have been shown to directly identify S. aureus from positive blood cultures, only nucleic acid amplification modalities have taken the approach of delineating MRSA and MSSA from other Gram-positive coccus etiologies of bloodstream infection (16). In spite of these advances, some clinical microbiology laboratories may be apprehensive to implement these technologies due to financial considerations. Stamper et al. (20) reported on the utility of the BD GeneOhm StaphSR assay for direct identification and methicillin resistance profiling of coagulase-positive staphylococci from positive blood culture bottles, citing sensitivity and specificity values of ≥98.4% for MRSA and ≥96.7% for MSSA. In this report, we describe a modification of the protocol for reconstitution and storage of BD GeneOhm StaphSR assay master mix that not only allows for efficient detection of MRSA and MSSA but also promotes greater economy in reagent utilization.(The results of this work were presented in part at the 109th General Meeting of the American Society for Microbiology, Philadelphia, PA, 17 to 21 May 2009 [15].)In an institutional review board-approved protocol, one positive BacT/Alert SA or SN bottle (bioMérieux, Durham, NC) from consecutive septic episodes with a Gram stain morphology of Gram-positive cocci in pairs or clusters was processed to a lysate form for the BD GeneOhm StaphSR assay (BD Diagnostics, Ste-Foy, Quebec, Canada) per the manufacturer''s specifications. Vials containing lyophilized master mix were reconstituted with 225 μl of kit-provided diluent according to the manufacturer''s instructions; 25-μl aliquots were distributed into empty SmartCycler reaction tubes (Cepheid, Sunnyvale, CA) that were placed into a 4°C cooling block (freshly reconstituted master mix). In an experimental protocol, vials containing lyophilized master mix were reconstituted with 225 μl of kit-provided diluent; 25-μl aliquots were distributed into empty SmartCycler reaction tubes that were placed into a 4°C cooling block. The tubes were closed tightly, removed from the cooling block, and allowed to stand upright at −70°C for long-term storage protected from light (frozen master mix). Prior to storage, 3.0-μl aliquots of kit-provided nucleic acid (positive control) or sample buffer (negative control) were added to a subset of master mix aliquots.Aliquots (3.0 μl) of processed lysates were delivered to either frozen master mix tubes that were allowed to acclimate for 5 min in a 4°C cooling block or freshly reconstituted master mix. All reaction tubes were pulse centrifuged for 5 to 10 s and loaded onto a SmartCycler fluorescence thermal cycler (Cepheid) for 45 cycles of PCR. The lysates were subsequently frozen at −20°C. Potency studies involved incubation of archived positive (MRSA), reactive (MSSA), and negative lysates in both freshly reconstituted master mix and frozen master mix that had been stored for 1 week to 6 months at −70°C. In addition, control material frozen for 3, 9, and 18 weeks was subjected to PCR analysis. A prospective clinical study analyzed 244 lysates in tandem using freshly reconstituted master mix and 1-week-frozen master mix. All organisms from positive blood cultures were identified using standard microbiological techniques. Penicillinase-stable penicillin susceptibility results were determined by cefoxitin disk diffusion testing (22). Lysates demonstrating amplification inhibition (unresolved result) were thawed and repeat tested by PCR according to the manufacturer''s instructions. Concordant results generated by PCR from freshly reconstituted and frozen master mix constituted reference results.Forty previously analyzed lysates (10 MRSA strains, 10 MSSA strains, 12 coagulase-negative Staphylococcus [CNS] strains, and 8 Micrococcus strains) were incubated in freshly reconstituted master mix and in master mix frozen from 1 week to 6 months. The expected results were generated in all instances. Temporal cycle threshold (CT) profiles for two representative lysates from each classification are illustrated in Fig. Fig.1.1. The CT values for the two MRSA lysates (Fig. (Fig.1A)1A) ranged from 27.7 to 28.8 and from 26.1 to 27.0 and did not exhibit significant changes in frozen master mix potency (P = 0.58; one-way analysis of variance). Similarly, unchanged potency of frozen master mix over time was demonstrated with MSSA lysates (Fig. (Fig.1B),1B), with CT value ranges of 27.1 to 28.2 and 24.1 to 25.6 (P = 0.11). Detection of internal-control nucleic acid (Fig. (Fig.1C)1C) was not significantly affected by interval of frozen master mix, with CT value ranges of 32.9 to 34.3 and 33.5 to 34.6 (P = 0.73).Open in a separate windowFIG. 1.(A and B) Cycle threshold (CT) values for BD GeneOhm StaphSR assay master mix frozen at variable intervals prior to incubation with lysates derived from clinical blood cultures yielding methicillin-resistant Staphylococcus aureus (A) and methicillin-susceptible Staphylococcus aureus (B). Data from two representative lysates are exhibited per panel and are shaded accordingly. (C) Internal-control CT for frozen master mix incubated with representative coagulase-negative Staphylococcus lysates (solid black bars) and Micrococcus lysates (gray dotted bars).Preparation of assay controls with reconstituted master mix and subsequent storage at −70°C for 3, 9, and 18 weeks (mean of 12 determinations per parameter) resulted in expected amplification of target staphylococcal and internal-control sequences (Table (Table1).1). A mean CT value increase was noted between 9- and 18-week-frozen prepared negative-control material (P = 0.003; t test for independent samples). In spite of this difference, the efficacy of 18-week-frozen master mix in amplification of internal-control nucleic acid (mean CT value of 34.59; Table Table1)1) was largely unchanged from amplification of internal-control nucleic acid via freshly reconstituted master mix (mean CT value of 34.63).

TABLE 1.

Mean cycle threshold (CT) values for replicates of prepared BD GeneOhm StaphSR assay positive- and negative-control reagents frozen at −70°C for 3 weeks, 9 weeks, and 18 weeksa
Reconstituted reagentMean CT ± SD following −70°C storage for:
3 wks9 wks18 wks
Positive controlb35.15 ± 0.2935.20 ± 0.2435.40 ± 0.22
Negative controlc33.87 ± 0.4334.10 ± 0.4034.59 ± 0.16
Open in a separate windowaCT values for negative-control material are indicative of internal-control amplification.bThe mean CT value ± standard deviation for freshly prepared positive-control reagent (22 determinations) was 34.67 ± 0.48.cThe mean CT value ± standard deviation for freshly prepared negative-control reagent (22 determinations) was 34.63 ± 0.32.Analysis of 244 lysates derived from positive blood cultures in freshly reconstituted master mix and frozen master mix yielded three discordant results attributable to unresolved results (two unresolved results for freshly reconstituted master mix and one unresolved result for frozen master mix). After repeat testing of frozen lysates, 100% final concordance between freshly reconstituted and frozen master mix was demonstrated. Final microbiology results included 160 (65.6%) monobacteremic instances of CNS, 35 (14.3%) of MSSA, and 25 (10.2%) of MRSA. Three discrepant results were observed in which the BD GeneOhm StaphSR assay was positive for detection of MRSA and microbial identification was consistent with MSSA. These discrepant results were confirmed by positive MRSA results derived from off-label testing of the blood culture lysates with the BD GeneOhm MRSA assay (targeting the same staphylococcal cassette chromosome mec [SCCmec]/orfX junction as the BD GeneOhm StaphSR assay for MRSA detection) as well as positive MRSA results from testing the S. aureus isolates via the BD GeneOhm StaphSR assay. Further mecA characterization was not performed to resolve or determine the cause of the discordant results; however, utilization of frozen master mix made no contribution to the discrepancies. Studies have demonstrated that mecA dropouts (5, 12) and partial deletions (8) yield such PCR/culture discrepancies in the context of the BD GeneOhm MRSA assay.While accurate identification of MRSA in bloodstream infection is critical for effective clinical management of patients (2, 4, 18), other data suggest that real-time detection of MSSA may prove to be of equal importance. Small and Chambers (19) have shown decreased in vitro bactericidal activity of vancomycin against recent MSSA strains compared to nafcillin. This translated into a vancomycin clinical failure rate of 38% for endocarditis caused by MSSA among intravenous drug abusers. In contrast, the failure rate for monotherapy with antistaphylococcal β-lactam agents was <3%, as derived from a meta-analysis of MSSA endocarditis within the same demographic (19). Gentry et al. (9) demonstrated complete response in 74% and 50% of patients who were administered nafcillin and vancomycin, respectively, for MSSA endocarditis. Chang et al. (1) reported higher treatment failure rates in patients with MSSA bloodstream infection who were managed with vancomycin (20%) than those who were managed with nafcillin (4%). Furthermore, these studies document a longer persistence of bacteremia following vancomycin therapy.Although PCR-based assays can play an important role in selection of therapy for bloodstream infections due to MRSA or MSSA, the cost of PCR technology may be prohibitive to a number of health care institutions. Relating this issue of economy to a specific commercial MRSA/MSSA PCR assay, the BD GeneOhm StaphSR assay provides lyophilized master mix in approximate 25-cm3 volumes in individual vials and directs the user to reconstitute each vial with 225 μl of kit-provided diluent. Although the final reconstitution volume exceeds 200 μl (actually approximating 250 μl), it is suggested by the manufacturer that eight 25-μl aliquots are available for PCR assays involving patient specimens and appropriate positive and negative controls. Because freshly reconstituted master mix is stable for only 3 h in the original vial at 2 to 8°C per package insert, laboratories may be unable to utilize all potential aliquots for PCR testing. As an example, when eight potential aliquots are yielded from reconstitution of a lyophilized master mix vial for a patient lysate batch size of three (with controls bringing the total batch size to five), three of the eight aliquots (37.5%) may be unused (Table (Table2).2). If it is further assumed that laboratories contribute to diagnosis of staphylococcal bloodstream infection in a real-time fashion, then a random distribution of batch sizes may be realized over a continuum. Based on these assumptions, on average, 31.3% of master mix would go unused if eight aliquots were consistently generated upon lyophilized master mix reconstitution. That figure would increase to 45% if 10 aliquots were consistently generated from lyophilized master mix reconstitution.

TABLE 2.

Hypothetical number of unused aliquots of freshly reconstituted master mix, on the basis of lysate batch size, under current BD GeneOhm StaphSR assay specificationsa
Lysate batch size (no. of lysates) [with controls included]No. (%) of unused aliquots per master mix vial following reconstitution
8 aliquots9 aliquots10 aliquots
1 [3]5 (62.5)6 (66.7)7 (70.0)
2 [4]4 (50.0)5 (55.6)6 (60.0)
3 [5]3 (37.5)4 (44.4)5 (50.0)
4 [6]2 (25.0)3 (33.3)4 (40.0)
5 [7]1 (12.5)2 (22.2)3 (30.0)
6 [8]0 (0.0)1 (11.1)2 (20.0)
Mean % of unused aliquots per random distribution batch size31.338.945.0
Open in a separate windowaMandated controls are added to batch size prior to the calculation of unused reaction tubes.With these rather substantial percentages of potential reagent waste, laboratories may be forced to batch patient lysates for PCR, thus not fully taking advantage of the real-time capacity of the assay. We hypothesized that reconstituting master mix as recommended and freezing at −70°C would maximize reagent utilization without compromising assay performance. Kofler and Klausegger (13) described an in-house PCR for detection of human cytomegalovirus from clinical specimens that utilized preformulated aliquots of master mix stored in 200-μl thin-walled tubes at −20°C. Hoorfar et al. (11) showed that reaction mixtures specific for Salmonella enterica 5′ nuclease PCR were stable for 3 months when stored in microwell plates at −20°C. West and Sawyer (23) reported that aliquots of preformulated master mix from four real-time PCR assays could be stored at −70°C without deleteriously affecting performance.We also reported an effective master mix reconstitution and storage paradigm for a commercial MRSA PCR assay (14). Reconstituted BD GeneOhm MRSA master mix was frozen for up to 4 weeks at −70°C and retained potency, provided that prepared SmartCycler tubes were protected from light and allowed to acclimate in 4°C conditions. These same environmental conditions were employed in the current assessment of BD GeneOhm StaphSR frozen master mix, and a comparable efficacy was observed. Final concordance rates of ≥98.8% were noted in prospective studies of frozen and freshly reconstituted master mix with the BD GeneOhm MRSA (14) and StaphSR assays. Data presented in this study confirm and extend the frozen master mix paradigm. No change in CT data was detected when the potency of frozen BD GeneOhm StaphSR master mix was tested 6 months after reconstitution. This would potentially benefit smaller laboratories who may encounter fewer instances of bloodstream infection. Of further importance, we demonstrated that control reagents can be prepared in the same fashion as frozen master mix.In conclusion, the kit-provided lyophilized master mix and control reagents that were reconstituted and stored for prolonged periods of time at −70°C retain sufficient potency for routine performance of the BD GeneOhm StaphSR assay. Freezing of the master mix results in cost-effective kit utilization and can assist in establishing efficient work flow practices. Smaller-volume laboratories can therefore more advantageously utilize PCR technology for a real-time contribution to clinical management of staphylococcal bloodstream infection.  相似文献   
9.
10.
BACKGROUND: Certain activities expose travellers to Coxiella burnetii, the causative agent of acute human Q fever. Awareness of Q fever must be improved, also as a potential imported disease, but delayed seroconversion and serological cross-reactivity complicate the diagnosis. Granulomatous inflammation of liver and bone marrow can be typical histopathological findings. CASE PRESENTATIONS: We present three imported cases of Q fever with different clinical presentations, in which the travel history identified the sources of infection. CONCLUSIONS: Q fever should be suspected in any imported febrile disease of unknown origin. Clinical manifestations are variable and repeated serological testing is mandatory. In some cases diagnostic biopsies might help to establish early diagnosis.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号