Moderate sedatives have been increasingly used to improve patient comfort during flexible bronchoscopy (FB). However, routine use of moderate sedation during FB is controversial because its efficacy and safety are not well established.This study aims to evaluate the efficacy and safety of moderate sedation during FB.A search was made of Medline, EMBASE, and the Cochrane Library to May 2014.Randomized controlled trials (RCTs) and quasi-RCTs were included.The main analysis was designed to examine the efficacy of moderate sedation during FB in sedation than no-sedation.The willingness to repeat FB was significantly more in sedation than no-sedation (odds ratio [OR] 2.30; 95% confidence interval [CI] 1.11–4.73; P = 0.02; I2 = 22.5). The duration of FB was shorter in sedation group than no-sedation group (standardized mean difference [SMD] −0.21; 95% CI −0.38 to −0.03; P = 0.02; I2 = 78.3%). Event of hypoxia was not significantly different between sedation and no-sedation groups (OR 0.86; 95% CI 0.42–1.73; P = 0.67; I2 = 0%). The SpO2 during procedure was not different between sedation and no-sedation groups (SMD −0.14; 95% CI −0.37 to 0.08; P = 0.21; I2 = 49.9%). However, in subgroup analysis without supplemental oxygen, the SpO2 was significantly lower in sedation than no-sedation group (SMD −0.45; 95% CI −0.78 to −0.11; P = 0.01; I2 = 0.0%).According to this meta-analysis, moderate sedation in FB would be useful in patients who will require repeated bronchoscopies as well as safe in respiratory depression. To our knowledge, although the various sedative drugs are already used in the real field, this analysis was the first attempt to quantify objective results. We anticipate more definite and studies designed to elucidate standardized outcomes for moderate sedation in FB. 相似文献
Three‐dimensional (3D) printing technology, virtual reality, and augmented reality technology have been used to help surgeons to complete complex total hip arthroplasty, while their respective shortcomings limit their further application. With the development of technology, mixed reality (MR) technology has been applied to improve the success rate of complicated hip arthroplasty because of its unique advantages. We presented a case of a 59‐year‐old man with an intertrochanteric fracture in the left femur, who had received a prior left hip fusion. After admission to our hospital, a left total hip arthroplasty was performed on the patient using a combination of MR technology and 3D printing technology. Before surgery, 3D reconstruction of a certain bony landmark exposed in the surgical area was first performed. Then a veneer part was designed according to the bony landmark and connected to a reference registration landmark outside the body through a connecting rod. After that, the series of parts were made into a holistic reference registration instrument using 3D printing technology, and the patient's data for bone and surrounding tissue, along with digital 3D information of the reference registration instrument, were imported into the head‐mounted display (HMD). During the operation, the disinfected reference registration instrument was installed on the selected bony landmark, and then the automatic real‐time registration was realized by HMD through recognizing the registration landmark on the reference registration instrument, whereby the patient's virtual bone and other anatomical structures were quickly and accurately superimposed on the real body of the patient. To the best of our knowledge, this is the first report to use MR combined with 3D printing technology in total hip arthroplasty. 相似文献
Objective: To evaluate the long-term clinical effect of high-intensity focussed ultrasound (HIFU) as a non-invasive modality for ablation of abdominal wall endometriosis (AWE) foci.
Methods: All women who were diagnosed with cutaneous endometriosis and underwent HIFU ablation and 4-year follow-up were included. Patient symptoms, imaging performed, HIFU ablation, recurrence, lesion location, size and number were collected and analyzed.
Results: A total of 51 women with 57 painful abdominal wall masses with a median volume of 4.00?cm3 and a mean age of 30.5±2.12 years were treated with HIFU. The main symptoms were a palpable painful abdominal mass (93%), protrusion of the skin (28.1%, 16) or lack of protrusion of the skin (71.9%, 41). Ultrasound was initially performed in 100% (51) of women, whereas 6% (3) required MRI examinations to distinguish the features and range of the masses. Ablation was performed with a median 300?s of sonication time, 40?min treatment time, 150?W of power and 41800?J of total energy to treat lesions that were a median volume of 3.83?cm3. No severe complications occurred, except in one patient with a first-degree skin burn, during the 48-month follow-up period. The pooled recurrence of cutaneous endometriosis occurred in 3.9% (2) of women.
Conclusion: The diagnosis of AWE should be confirmed with imaging of the lesion number, location, size and features before HIFU ablation. HIFU should be the first choice for the treatment of AWE as it is a non-invasive method, with high efficiency and safety and rapid postoperative recovery. 相似文献
A pulmonary artery (PA) sling is a very rare congenital cardiovascular anomaly, and only a few studies have reported PA slings in fetuses. The relationship of the PA, aorta, ductus arteriosus, and trachea can be evaluated in the 3‐vessel and 3‐vessel and trachea views during fetal echocardiography. A PA sling can be detected by abnormal positioning of the left PA in relation to the trachea when sweeping from the 3‐vessel view cranially to the 3‐vessel and trachea view. Here we report 3 cases of fetal PA slings and their follow‐ups. Two cases were confirmed by postnatal echocardiography, and the other case was confirmed by a cardiovascular cast after pregnancy termination. We emphasize that the 3‐vessel and 3‐vessel and trachea views are of crucial importance in the prenatal diagnosis of a PA sling. 相似文献