Physical activity brings significant health benefits to middle-aged adults, although the research to date has been focused on late adulthood. This study aims to examine how ageing affects the self-reported and accelerometer-derived measures of physical activity levels in middle-aged adults. We employed the data recorded in the UK Biobank and analysed the physical activity levels of 2,998 participants (1381 men and 1617 women), based on self-completion questionnaire and accelerometry measurement of physical activity. We also assessed the musculoskeletal health of the participants using the dual-energy X-ray absorptiometry (DXA) measurements provided by the UK Biobank. Participants were categorised into three groups according to their age: group I younger middle-aged (40 to 49 years), group II older middle-aged (50 to 59 years), and group III oldest middle-aged (60 to 69 years). Self-reported physical activity level increased with age and was the highest in group III, followed by group II and I (P?<?0.05). On the contrary, physical activity measured by accelerometry decreased significantly with age from group I to III (P?<?0.05), and the same pertained to the measurements of musculoskeletal health (P?<?0.05). It was also shown that middle-aged adults mostly engaged in low and moderate intensity activities. The opposing trends of the self-reported and measured physical activity levels may suggest that middle-aged adults over-report their activity level as they age. They should be aware of the difference between their perceived and actual physical activity levels, and objective measures would be useful to prevent the decline in musculoskeletal health.
In clinical and epidemiological studies, there is a growing interest in studying the heterogeneity among patients based on longitudinal characteristics to identify subtypes of the study population. Compared to clustering a single longitudinal marker, simultaneously clustering multiple longitudinal markers allow additional information to be incorporated into the clustering process, which reveals co-existing longitudinal patterns and generates deeper biological insight. In the current study, we propose a Bayesian consensus clustering (BCC) model for multivariate longitudinal data. Instead of arriving at a single overall clustering, the proposed model allows each marker to follow marker-specific local clustering and these local clusterings are aggregated to find a global (consensus) clustering. To estimate the posterior distribution of model parameters, a Gibbs sampling algorithm is proposed. We apply our proposed model to the primary biliary cirrhosis study to identify patient subtypes that may be associated with their prognosis. We also perform simulation studies to compare the clustering performance between the proposed model and existing models under several scenarios. The results demonstrate that the proposed BCC model serves as a useful tool for clustering multivariate longitudinal data. 相似文献
PurposeThe purpose of this study was to make a systematic review and meta-analysis to determine the stent diameter (8 mm vs. 10 mm) that conveys better safety and clinical efficacy for transjugular intrahepatic portosystemic shunt (TIPS).Materials and methodsFour databases were used to identify clinical trials published from inception until March 2020. Data were extracted to estimate and compare one-year and three-year overall survivals, hepatic encephalopathy, variceal rebleeding, and shunt dysfunction rates between patients with 8 mm covered stents and those with 10 mm covered stents.ResultsFive eligible studies were selected, which included 489 patients (316 men, 173 women). The 8 mm covered stent group had higher efficacy regarding one-year or three-year overall survival (odds ratio [OR], 2.88; P = 0.003) and (OR, 1.81; P = 0.04) and lower hepatic encephalopathy (OR, 0.69; P = 0.04) compared with 10 mm covered stent group. There were no significant differences in variceal rebleeding rate (OR 0.80; P = 0.67). However, shunt dysfunction was lower in 10 mm covered stent group (OR, 2.26; P = 0.003).ConclusionsOur results suggest that the use of 8 mm covered stents should be preferred to that of 10 mm covered stents for TIPS placement when portal pressure is frequently monitored. 相似文献
Near-infrared diffuse correlation spectroscopy/tomography (DCS/DCT) has recently emerged as a noninvasive measurement/imaging technology for tissue blood flow. In DCT studies, the high-dense collection of light temporal autocorrelation curves (g2(τ)) via fiber array are critical for image reconstruction of blood flow. Previously, the camera-based fiber array limits the field of view (FOV), precluding its applications on large-size human tissues. The line-shape fiber probe based on lens combination, which is predominantly used in current DCT studies, requires rotated-scanning over the surface of target tissue, substantially prolonging the measurement time and increasing the system instability. In this study, we design a noncontact optical probe for DCT based on collimating micro-lens fiber array, termed as FA-nc-DCT system. For each source/detector fiber, a single optical path was collimated by coupling with one micro-lens in the fiber array that is integrated in a square-shape base. Additionally, an 8×8 optical switch is used to share the hardware laser and detectors without spatial scanning. The FA-nc approach for the precise collection of g2(τ) curves was validated through a speed-varied phantom experiment and the human experiments of cuff occlusion, from which the expected value of the blood flow index (BFI) was obtained. Furthermore, the flow anomaly in the phantom and the ischemic muscle in human were accurately reconstructed from the FA-nc-DCT system, which is combined with the imaging framework based on the Nth-order linear algorithm that we recently created. Those outcomes demonstrated the great potential of FA-nc-DCT technology for fast and robust imaging of various diseases such as human breast cancers. 相似文献