Long-term use of cyclosporine after renal transplantation results in nephrotoxicity and an increased cardiovascular risk profile. Tacrolimus may be more favorable in this respect. In this randomized controlled study in 124 renal transplant patients, the effects of conversion from cyclosporine to tacrolimus on renal function, cardiovascular risk factors, and perceived side-effects were investigated after a follow-up of 2 years. After conversion from cyclosporine to tacrolimus renal function remained stable, whereas continuation of cyclosporine was accompanied by a rise in serum creatinine from 142 +/- 48 micromol/L to 157 +/- 62 micromol/L (p < 0.05 comparing both groups). Conversion to tacrolimus resulted in a sustained reduction in systolic and diastolic blood pressure, and a sustained improvement in the serum lipid profile, leading to a reduction in the Framingham risk score from 5.7 +/- 4.3 to 4.8 +/- 5.3 (p < 0.05). Finally, conversion to tacrolimus resulted in decreased scores for occurrence of and distress due to side-effects. In conclusion, conversion from cyclosporine to tacrolimus in stable renal transplant patients is beneficial with respect to renal function, cardiovascular risk profile, and side-effects. Therefore, for most renal transplant patients tacrolimus will be the drug of choice when long-term treatment with a calcineurin inhibitor is indicated. 相似文献
Introduction Failure to enter the coronary sinus (CS) with a guiding catheter and entering its tributaries remains challenging in left
ventricle (LV) pacing lead implants for cardiac resynchronization therapy (CRT). A dual telescoping catheter system (8F outer/6F
inner) is designed to provide the ability to adjust the catheter curve size, shape and/or reach to the patients’ anatomy avoiding
the need for catheter change.
Methods Five different designs for CS cannulation were randomly tested in 64 patients scheduled for CRT device implant.
Results In 33 consecutive patients three adaptable telescoping guiding catheter systems were tested per patient, the adaptable catheters
had higher overall cannulation success rates (68, 63 and 62%) compared to the fixed shape catheter (46%) and an greater cannulation
success rate when the CS location was not known (70, 53 and 72% vs 33% for the fixed shape). In a second group of 31 CRT patients
the two telescoping catheters had similar high levels of success (71–80%), with or without using the inner catheter.
Conclusions The telescopic system is adaptable to a wide range of anatomical variations in patients and can result in a higher CS cannulation
success rate due to its adjustability in the RA in search for the CS ostium. On top of this the inner catheter allows for
sub-selecting the CS tributaries. 相似文献
A high-performance liquid chromatographic (HPLC) method is described for the assay of the active metabolite [1-(2-pyrimidinyl)piperazinel of buspirone, an anxiolytic agent, in rat plasma.
The method is based on the use of ion-pair HPLC coupled to a liquid—solid extraction scheme. Samples of rat plasma (2 ml) with internal standard (1-phenylpiperazine), adjusted to pH 10.5 with borate buffer, were loaded on to a preactivated C-18 cartridge. The metabolite and the internal standard were eluted with 5 ml of methanol and injected on to a reversed-phase 10-μm Spherisorb ODS-2 column. The column was eluted with a mobile phase of 0.005 M sodium lauryl sulphate in citrate buffer (pH 3.6)-acetonitrile (65:35, v/v) at 2 ml min−1. Detection was carried out at 248 nm. The recovery of the metabolite was 55%. The method was applied to the determination of the metabolite in rat plasma after oral dosing (25 mg kg−1) of the parent compound. 相似文献
Mortality in HIV-infected patients has decreased dramatically since the introduction of highly active antiretroviral therapy (HAART). We analyzed progression to death in a population of 3678 antiretroviral treatment-naive patients from the ATHENA national observational cohort from 24 weeks after the start of HAART. Mortality was compared with that in the general population in the Netherlands matched by age and gender. Only log-transformed CD4 cell count (hazard ratio [HR] = 0.50, 95% confidence interval [CI]: 0.40 to 0.61 per unit increase) and plasma viral load (HR = 0.30, 95% CI: 0.15 to 0.60, HIV RNA level <100,000 vs. > or = 100,000 copies/mL) measured at 24 weeks and infection via intravenous drug use (IDU) (HR = 0.16, 95% CI: 0.10 to 0.26, non-IDU vs. IDU) were significantly associated with progression to death. For non-IDU patients with 600 x 10 CD4 cells/L and an HIV RNA level <100,000 copies/mL at 24 weeks, mortality was predicted to be 5.3 (95% CI: 3.5 to 8.4) and 10.4 (95% CI: 6.4 to 17.4) times higher than in the general population for 25-year-old men and women, respectively, and 1.15 (95% CI: 1.08 to 1.25) and 1.29 (95% CI: 1.16 to 1.50) times higher for 65-year-old men and women, respectively. Hence, mortality in HIV-infected patients with a good initial response to HAART is still higher than in the general population. 相似文献
A PCR protocol was developed to detect Helicobacter pylori in human stool specimens. This protocol was based on the association of a magnetic immuno-PCR assay with a technique to remove inhibitors (agarose-embedded DNA preparation). Of the 47 H. pylori-positive and 57 H. pylori-negative patients included in this study, 38 were positive and 66 were negative by this new protocol. The sensitivity, specificity, and predictive values for a positive or a negative result were 80.9% (95% confidence interval [CI], 66.3 to 90.4), 100% (95% CI, 92.1 to 100), 100% (95% CI, 88.6 to 100), and 86.4% (95% CI, 75.2 to 93.2), respectively. 相似文献
To evaluate whether vaccine administration via intragastric gavage is indicative for the outcome of edible vaccines, mice were orally immunised with ovalbumin (OVA) mixed with or without Vibrio cholerae toxin (CT) in various compositions via various routes: (1) OVA dissolved in saline and intragastrically (IG) administered ('IG'); (2) OVA mixed with food extract and administered IG ('food IG'); (3) food chow absorbed with OVA dissolved in saline and fed to the animals ('food'); and (4) OVA dissolved in saline and administered via drinking bottles ('drinking'). When given to naive mice, 'IG' and 'food IG' but not 'food' or 'drinking' induced anti-OVA IgG1 responses in serum, but oral boost immunisations were necessary. Serum IgA was not induced. Oral boosting of subcutaneously (SC) primed mice enhanced the IgG1 and IgA response in serum regardless of the route of immunisation or the vaccine composition. CT did not dramatically enhance the immune response. All immunisation routes except 'drinking' induced antigen-specific IgA antibody secreting cells (ASC) in the lamina propria of naive mice. But antigen-specific antibody responses in faeces were not observed. We concluded that oral (i.e. IG) administration is distinct from oral intake. The composition of the vaccine (food or saline) did not influence oral administration. We thus suggested that the route of administration greatly influenced the outcome of oral immunisation. Although oral administration is a well-accepted route to test the potentials of oral vaccines, our study demonstrated that it is merely indicative for the effectiveness of edible vaccines. Studies on the feasibility of edible vaccines should thus be performed by eating the vaccine. 相似文献
ObjectivesDialysis patients report a low health-related quality of life (HRQOL) due to high disease burden and far-reaching consequences of dialysis treatment. This study examined several cognitive-behavioral and social factors, with a focus on negative outcome expectancies, that might be relevant for HRQOL in end-stage kidney disease (ESKD) patients treated with dialysis.MethodsPatients treated with hemodialysis or peritoneal dialysis were recruited from Dutch hospitals and dialysis centers. Patients completed self-report questionnaires at baseline (n = 175) and six months follow-up (n = 130). Multiple regression analyses were performed.ResultsHigher scores on factors related to negative outcome expectancies at baseline, especially helplessness and worrying, and less perceived social support were significantly related to worse HRQOL six months later. When controlling for baseline HRQOL, besides sex and comorbidity, helplessness remained significantly predictive of worse HRQOL six months later, indicating that helplessness is associated with changes in HRQOL over time.ConclusionsNegative outcome expectancies and social support are relevant markers for HRQOL and/or changes in HRQOL over time.Practice implicationsNegative outcome expectancies could be prevented or diminished by enhanced treatment information, an improved patient-clinician relationship, and interventions that promote adaptive and realistic expectations. Additionally, increasing supportive social relationships could be a relevant treatment focus. 相似文献
The earliest studies on ‘disability glare’ date from the early 20th century. The condition was defined as the negative effect on visual function of a bright light located at some distance in the visual field. It was found that for larger angles (>1degree) the functional effect corresponded precisely to the effect of a light with a luminosity equal to that of the light that is perceived spreading around such a bright source. This perceived spreading of light was called straylight and by international standard disability glare was defined as identical to straylight. The phenomenon was recognized in the ophthalmological community as an important aspect of the quality of vision and attempts were made to design instruments to measure it. This must not be confused with instruments that assess light spreading over small distances (<1 degree), as originating from (higher order) aberrations and defocus. In recent years a new instrument has gained acceptance (C-Quant) for objective and controllable assessment of straylight in the clinical setting. This overview provides a sketch of the historical development of straylight measurement, as well as the results of studies on the origins of straylight (or disability glare) in the normal eye, and on findings on cataract (surgery) and corneal conditions. 相似文献