Interstitial lung disease (ILD) represents a significant cause of morbidity and mortality in systemic sclerosis (SSc). The purpose of this study was to examine recirculating lymphocytes from SSc patients for potential biomarkers of interstitial lung disease (ILD). Peripheral blood mononuclear cells (PBMCs) were isolated from patients with SSc and healthy controls enrolled in the Vanderbilt University Myositis and Scleroderma Treatment Initiative Center cohort between 9/2017–6/2019. Clinical phenotyping was performed by chart abstraction. Immunophenotyping was performed using both mass cytometry and fluorescence cytometry combined with t-distributed stochastic neighbor embedding analysis and traditional biaxial gating. This study included 34 patients with SSc-ILD, 14 patients without SSc-ILD, and 25 healthy controls. CD21lo/neg cells are significantly increased in SSc-ILD but not in SSc without ILD (15.4 ± 13.3% vs. 5.8 ± 0.9%, p = 0.002) or healthy controls (5.0 ± 0.5%, p < 0.0001). While CD21lo/neg B cells can be identified from a single biaxial gate, tSNE analysis reveals that the biaxial gate is comprised of multiple distinct subsets, all of which are increased in SSc-ILD. CD21lo/neg cells in both healthy controls and SSc-ILD are predominantly tBET positive and do not have intracellular CD21. Immunohistochemistry staining demonstrated that CD21lo/neg B cells diffusely infiltrate the lung parenchyma of an SSc-ILD patient. Additional work is needed to validate this biomarker in larger cohorts and longitudinal studies and to understand the role of these cells in SSc-ILD.
ObjectiveEach pulmonary segment is an anatomical and functional unit. However, it is fundamentally difficult to precisely distinguish every pulmonary segment using the conventional pulmonary intersegmental planes from computed tomography images. Building arteriopulmonary segments is likely to be an effective way to identify pulmonary segments.MethodsThe thoracic computed tomography images of 40 patients were collected. The anatomic structures of interest were extracted in the transverse, sagittal, and coronal planes using the semi-automated segmentation tools provided by Amira software. The intrapulmonary vessels were subsequently segmented and reconstructed. The distributions of the pulmonary arteries, veins, and bronchi were observed. In patients with pulmonary masses, the mass was also reconstructed.ResultsThe three-dimensional reconstructed images showed the branches of the pulmonary artery ramified up to their eighth order covering the entire lung as well as evident intersegmental gaps without pulmonary arteries. The segmental artery was closely accompanied by the segmental bronchi in 486 pulmonary segments (90% of total number of segments). The size and spatial location of the pulmonary mass within a pulmonary segment were also clearly visible.ConclusionsDemarcation of arteriopulmonary segments can be used to precisely distinguish every pulmonary segment and provide its detailed anatomical structure before pulmonary segmentectomy. 相似文献
PurposeThe purpose of this study was to make a systematic review and meta-analysis to determine the stent diameter (8 mm vs. 10 mm) that conveys better safety and clinical efficacy for transjugular intrahepatic portosystemic shunt (TIPS).Materials and methodsFour databases were used to identify clinical trials published from inception until March 2020. Data were extracted to estimate and compare one-year and three-year overall survivals, hepatic encephalopathy, variceal rebleeding, and shunt dysfunction rates between patients with 8 mm covered stents and those with 10 mm covered stents.ResultsFive eligible studies were selected, which included 489 patients (316 men, 173 women). The 8 mm covered stent group had higher efficacy regarding one-year or three-year overall survival (odds ratio [OR], 2.88; P = 0.003) and (OR, 1.81; P = 0.04) and lower hepatic encephalopathy (OR, 0.69; P = 0.04) compared with 10 mm covered stent group. There were no significant differences in variceal rebleeding rate (OR 0.80; P = 0.67). However, shunt dysfunction was lower in 10 mm covered stent group (OR, 2.26; P = 0.003).ConclusionsOur results suggest that the use of 8 mm covered stents should be preferred to that of 10 mm covered stents for TIPS placement when portal pressure is frequently monitored. 相似文献