首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   28篇
  免费   0篇
妇产科学   2篇
基础医学   1篇
临床医学   8篇
内科学   4篇
外科学   6篇
药学   2篇
肿瘤学   5篇
  2022年   1篇
  2021年   2篇
  2017年   1篇
  2016年   3篇
  2015年   2篇
  2014年   1篇
  2013年   1篇
  2012年   3篇
  2011年   2篇
  2010年   1篇
  2009年   1篇
  2008年   2篇
  2006年   2篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  1999年   1篇
排序方式: 共有28条查询结果,搜索用时 31 毫秒
1.

Assessment of size and growth are key radiological factors in low-grade gliomas (LGGs), both for prognostication and treatment evaluation, but the reliability of LGG-segmentation is scarcely studied. With a diffuse and invasive growth pattern, usually without contrast enhancement, these tumors can be difficult to delineate. The aim of this study was to investigate the intra-observer variability in LGG-segmentation for a radiologist without prior segmentation experience. Pre-operative 3D FLAIR images of 23 LGGs were segmented three times in the software 3D Slicer. Tumor volumes were calculated, together with the absolute and relative difference between the segmentations. To quantify the intra-rater variability, we used the Jaccard coefficient comparing both two (J2) and three (J3) segmentations as well as the Hausdorff Distance (HD). The variability measured with J2 improved significantly between the two last segmentations compared to the two first, going from 0.87 to 0.90 (p?=?0.04). Between the last two segmentations, larger tumors showed a tendency towards smaller relative volume difference (p?=?0.07), while tumors with well-defined borders had significantly less variability measured with both J2 (p?=?0.04) and HD (p?<?0.01). We found no significant relationship between variability and histological sub-types or Apparent Diffusion Coefficients (ADC). We found that the intra-rater variability can be considerable in serial LGG-segmentation, but the variability seems to decrease with experience and higher grade of border conspicuity. Our findings highlight that some criteria defining tumor borders and progression in 3D volumetric segmentation is needed, if moving from 2D to 3D assessment of size and growth of LGGs.

  相似文献   
2.
3.
4.
5.
ObjectiveEarly detection of frailty is essential to prevent or delay disability. The most appropriate screening tool for frailty among home-dwelling older adults is under debate. The present study estimates the prevalence of frailty among older adults, first-time applicants of public home care service in Norway, and investigates the appropriateness of gait speed and Short Physical Performance Battery as screening-tools for frailty.Design and settingWe conducted a cross-sectional study of 116 older adults >65 years applying for public home care service for the first time. Frailty was assessed by an adapted version of the Fried Frailty Phenotype. The test accuracies of gait speed and Short Physical Performance Battery to detect frailty were calculated for a general population >70 years in Norway.Results62.1% of the participants were frail, 29.3% were prefrail, and 8.6% were robust. Mean gait speed and Short Physical Performance Battery-scores were significantly lower in frail compared to prefrail individuals, and significantly lower in prefrail compared to robust individuals. The sensitivity and specificity of gait speed at a cut point of 0.8 m/s to detect physical frailty phenotype was 99% and 68%, respectively.Conclusions The high prevalence of frailty in the present study indicates that screening for frailty should be considered at an earlier time point than when older adults apply for public home care service for the first time. Gait speed may be an appropriate screening tool for frailty in a general population >70 years in Norway.

KEY POINTS

  • The prevalence of frailty among older adults, first-time applicants of public home care services in Norway is major.
  • Screening for frailty should be considered before older adults apply for public home care service for the first time.
  • Gait speed at a cut point at 0.8 m/s may be an appropriate screening tool for frailty in a general population >70 years in Norway.
  相似文献   
6.
The value of intensive therapy, including autologous stem cell transplantation, in newly diagnosed myeloma patients >60 years is not clear. We evaluated the impact of age (<60 years vs. 60-64 years) on survival in a prospective, population-based setting and compared survival with conventionally treated historic controls. The prospective population comprised 452 patients registered between 1998 and 2000. Of these, 414 received intensive therapy. The historic population, derived from our most recent population-based study on conventional therapy, comprised 281 patients. Of these, 243 fulfilled our eligibility criteria for intensive therapy. For patients undergoing intensive therapy it was found that two factors, beta-2-microglobulin and age <60 years vs. 60-64 years, had independent prognostic impact on survival. However, compared with the historic controls a survival advantage was found both for patients <60 (median 66 months vs. 43 months, P < 0.001) and 60-64 years (median 50 months vs. 27 months; P = 0.001). We conclude that in a population-based setting higher age adversely influences outcome after intensive therapy. Our results indicate that intensive therapy prolongs survival also at age 60-64 years but with less superiority than in younger patients.  相似文献   
7.
8.
9.

Background

Intraoperative ultrasound imaging is used in brain tumor surgery to identify tumor remnants. The ultrasound images may in some cases be more difficult to interpret in the later stages of the operation than in the beginning of the operation. The aim of this paper is to explain the causes of surgically induced ultrasound artefacts and how they can be recognized and reduced.

Methods

The theoretical reasons for artefacts are addressed and the impact of surgery is discussed. Different setups for ultrasound acquisition and different acoustic coupling fluids to fill up the resection cavity are evaluated with respect to improved image quality.

Results

The enhancement artefact caused by differences in attenuation of the resection cavity fluid and the surrounding brain is the most dominating surgically induced ultrasound artefact. The influence of the artefact may be reduced by inserting ultrasound probes with small footprint into the resection cavity for a close-up view of the areas with suspected tumor remnants. A novel acoustic coupling fluid developed for use during ultrasound imaging in brain tumor surgery has the potential to reduce surgically induced ultrasound artefacts to a minimum.

Conclusions

Surgeons should be aware of artefacts in ultrasound images that may occur during brain tumor surgery. Techniques to identify and reduce image artefacts are useful and should be known to users of ultrasound in brain tumor surgery.  相似文献   
10.

Purpose

CustusX is an image-guided therapy (IGT) research platform dedicated to intraoperative navigation and ultrasound imaging. In this paper, we present CustusX as a robust, accurate, and extensible platform with full access to data and algorithms and show examples of application in technological and clinical IGT research.

Methods

CustusX has been developed continuously for more than 15 years based on requirements from clinical and technological researchers within the framework of a well-defined software quality process. The platform was designed as a layered architecture with plugins based on the CTK/OSGi framework, a superbuild that manages dependencies and features supporting the IGT workflow. We describe the use of the system in several different clinical settings and characterize major aspects of the system such as accuracy, frame rate, and latency.

Results

The validation experiments show a navigation system accuracy of \(<\)1.1 mm, a frame rate of 20 fps, and latency of 285 ms for a typical setup. The current platform is extensible, user-friendly and has a streamlined architecture and quality process. CustusX has successfully been used for IGT research in neurosurgery, laparoscopic surgery, vascular surgery, and bronchoscopy.

Conclusions

CustusX is now a mature research platform for intraoperative navigation and ultrasound imaging and is ready for use by the IGT research community. CustusX is open-source and freely available at http://www.custusx.org.
  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号