Magnetic field generated by neuronal activity could alter magnetic resonance imaging (MRI) signals but detection of such signal is under debate. Previous researches proposed that magnitude signal change is below current detectable level, but phase signal change (PSC) may be measurable with current MRI systems. Optimal imaging parameters like echo time, voxel size and external field direction, could increase the probability of detection of this small signal change. We simulate a voxel of cortical column to determine effect of such parameters on PSC signal. We extended a laminar network model for somatosensory cortex to find neuronal current in each segment of pyramidal neurons (PN). 60,000 PNs of simulated network were positioned randomly in a voxel. Biot–savart law applied to calculate neuronal magnetic field and additional phase. The procedure repeated for eleven neuronal arrangements in the voxel. PSC signal variation with the echo time and voxel size was assessed. The simulated results show that PSC signal increases with echo time, especially 100/80 ms after stimulus for gradient echo/spin echo sequence. It can be up to 0.1 mrad for echo time = 175 ms and voxel size = 1.48 × 1.48 × 2.18 mm3. With echo time less than 25 ms after stimulus, it was just acquired effects of physiological noise on PSC signal. The absolute value of the signal increased with decrease of voxel size, but its components had complex variation. External field orthogonal to local surface of cortex maximizes the signal. Expected PSC signal for tactile detection in the somatosensory cortex increase with echo time and have no oscillation. 相似文献
A 42‐year‐old man presented with a viral prodrome and tested positive for influenza A. He rapidly deteriorated developing cardiogenic shock, rhabdomyolysis, and acute kidney injury. Patient improved 1 week later with supportive measures including vasopressors, inotropes, and an intraaortic balloon pump. We report this case as it highlights the discordance between echocardiographic ventricular wall thickening as a result of myocardial edema, and electrocardiographic findings at presentation, with a reversal in findings at time of resolution. Additionally, there was some suggestion of a regional pattern to the reduced longitudinal strain. 相似文献
Purpose: Spray-freeze drying (SFD) is a recently applied method to develop pharmaceutical powders. This study aimed to analyze the competence of Trehalose, Mannitol, Lactose, and Sorbitol instability and aerosolization of Immunoglobulin G (IgG) via SFD.
Methods: Induced soluble aggregates were quantified at 0 and 3?months, and 45?°C using size-exclusion chromatography. Conformation and thermogravimetric assessments were done by Fourier transform infrared spectroscopy and differential scanning calorimetry. Laser light scattering was performed to determine the particle sizes. Aerodynamic features were characterized by twin stage impinger and scanning electron microscopy.
Results: Although sugars/polyols preferably stabilized IgG following the process, storage stabilization was achieved in Trehalose, Trehalose-Lactose, Lactose, and Trehalose-Mannitol-based powders with soluble aggregates <5%. The conformation of antibody was preserved with β sheet content from 66.28% to 76.37%. Particle sizes ranged from 5.23 to 8.12?µm. Mannitol exhibited the best aerodynamic behavior, fine particle fraction (FPF: 70%) but high degree of protein aggregation during storage.
Conclusions: SFD could favorably stabilize antibody using Trehalose and its combination with Lactose and Mannitol, and also, Lactose alone. Sorbitol disturbed IgG powder recovery. Incorporation of other types of excipient is required for efficient respiratory delivery of IgG molecules. 相似文献
Background contextAnterior corpectomy and reconstruction with bone graft and a rigid screw-plate construct is an established procedure for treatment of cervical neural compression. Despite its reliability in relieving symptoms, there is a high rate of construct failure, especially in multilevel cases.PurposeThere has been no study evaluating the biomechanical effects of screw angulation on construct stability; this study investigates the C4–C7 construct stability and load-sharing properties among varying screw angulations in a rigid plate-screw construct.Study designA finite element model of a two-level cervical corpectomy with static anterior cervical plate.MethodsA three-dimensional finite element (FE) model of an intact C3–T1 segment was developed and validated. From this intact model, a fusion model (two-level [C5, C6] anterior corpectomy) was developed and validated. After corpectomy, allograft interbody fusion with a rigid anterior screw-plate construct was created from C4 to C7. Five additional FE models were developed from the fusion model corresponding to five different combinations of screw angulations within the vertebral bodies (C4, C7): (0°, 0°), (5°, 5°), (10°, 10°), (15°, 15°), and (15°, 0°). The fifth fusion model was termed as a hybrid fusion model.ResultsThe stability of a two-level corpectomy reconstruction is not dependent on the position of the screws. Despite the locked screw-plate interface, some degree of load sharing is transmitted to the graft. The load seen by the graft and the shear stress at the bone-screw junction is dependent on the angle of the screws with respect to the end plate. Higher stresses are seen at more divergent angles, particularly at the lower level of the construct.ConclusionThis study suggests that screw divergence from the end plates not only increases load transmission to the graft but also predisposes the screws to higher shear forces after corpectomy reconstruction. In particular, the inferior screw demonstrated larger stress than the upper-level screws. In the proposed hybrid fusion model, lower stresses on the bone graft, end plates, and bone-screw interface were recorded, inferring lower construct failure (end-plate fractures and screw pullout) potential at the inferior construct end. 相似文献
OBJECTIVE: There are several modifications introduced in the preparation for a subsequent non-surgical transcatheter completion of the Fontan procedure. We report our experience with one type of the modification and the short-term results following its implementation. METHODS: During bidirectional cavopulmonary connection (BCPC) an intra-atrial lateral tunnel is additionally created, as intended for a Fontan procedure but fenestrated with a 10-14 mm aperture. The cardiac end of the superior vena cava (SVC) is then patched to maintain the physiology of BCPC. During the interventional transcatheter completion procedure, the SVC patch is perforated using radio-frequency (RF) energy, balloon-dilated, and stented as well. The aperture is closed with a device when required. Paired t-test was used to compare data before and after the Fontan completion. RESULTS: From June 2003 to February 2006, 16 patients (9 boys and 7 girls, mean age 12 months) underwent the surgical procedure described. The mean bypass time was 137 min and the mean ischemic time was 77 min. There were no operative deaths. One patient with bilateral SVC required a take down due to recurrent effusions. Ten months later, nine patients underwent completion (mean age 20 months, mean weight 10.6 kg). The stents were dilated to a mean diameter of 14.4mm. All except one aperture was closed with a device. The mean fluoroscopy time was 41 min. Oxygen saturation increased from 85 to 94% (p=0.001). Pulmonary artery pressures remained normal (16 mmHg before and 19 mmHg after, p=0.12). No patients required mechanical ventilation and none developed pleural effusions or arrhythmias. All were discharged from hospital within 6 days of the Fontan completion. Twenty-two months after Fontan, all were well. Echocardiography revealed no gradients across the stents. Two patients had minor leaks across the aperture. One underwent further stent dilatation a year later. CONCLUSIONS: Fontan completion without surgery is suitable in patients with single ventricles with lower mortality and morbidity, avoids multiple surgical interventions while maintaining the staged approach and allows for successive dilatation of the Fontan pathway to accommodate for growth. 相似文献