The purpose of this study is to determine the role of liver biopsy and outcome of patients undergoing donor evaluation for adult-to-adult right hepatic lobe living donor liver transplantation (LDLT). Records of patients presenting for a comprehensive donor evaluation between 1997 and February 2005 were reviewed. Liver biopsy was performed only in patients with risk factors for abnormal histology. Two hundred and sixty patients underwent a comprehensive donor evaluation and 116 of 260 (45%) were suitable for donation, 14 of 260 (5.4%) did not complete evaluation and 130 of 260 (50%) were rejected. Four patients underwent unsuccessful hepatectomy surgery due to discovery of intraoperative abnormalities. Between 1997 and 2001, the acceptance rate of donor candidates (63%) was higher than 2002-2005 (36%), p < 0.0001. Sixty-six of the 150 eligible patients (44%) fulfilled criteria for liver biopsy and 28 of 66 (42%) had an abnormal finding. Less than half of the patients undergoing donor evaluation were suitable donors and the donor acceptance rate has declined over time. A large proportion of the patients undergoing liver biopsy have abnormal findings. Our evaluation process failed to identify 4 of 103 who had aborted donor surgeries. 相似文献
Objective: Considering the growing use of cellular phones and the fast appearance of new phone models, the electromagnetic interference of currently popular cellular phones on electronic medical equipment was tested. Methods: Three Personal Communication System cellular phones were put at different distances from multiple electronic medical devices, the interference effect was observed and the electromagnetic field strength measured with a spectrum analyser. Results: Only two small pieces of equipment, the CO2 airway adapter and the haemoglucostix meter were affected and then only when the phone was in very close proximity. Conclusion: Compared to the results of our study in 1997 testing Global System for Mobile Communication phones, the Personal Communication System phones generated less electromagnetic interference. However a much larger scaled study and an accurate international electromagnetic interference standard are recommended before any change in the current restrictive hospital policy on mobile phone usage could be recommended. 相似文献
SK&F 86466, 6-chloro-3-methyl-2,3,4,5-tetrahydro-1-H-3-benzazepine, is a potent and selective antagonist of the α2-adrenoceptor in vitro. This compound produced a small pressor response accompanied by a marked bradycardia when administered i.v. to the pithed normotensive rat. The pressor response was not affected by reserpine treatment, pretreatment with α- or β-adrenoceptor antagonists, atropine, or hexamethonium. The bradycardia was markedly reduced by bilateral vagotomy and pretreatment with atropine and attenuated by hexamethonium. The negative chronotropic action of SK&F 86466 was abolished by a combination of vagotomy and atropine. Mediation of the bradycardia by a baroreceptor reflex was ruled out by the observations that a lack of change in heart rate was associated with the vasopressor response to phenylephrine in the pithed rat pretreated with propranolol. It is concluded that the negative chronotropic action of SK&F 86466 in the pithed rat is mediated indirectly by activation of the cholinergic innervation of the heart. 相似文献
Polypropylene mesh is widely used for the reconstruction of incisional hernias that cannot be closed primarily. Several techniques have been advocated to implant the mesh. The objective of this study was to evaluate, retrospectively, early and late results of three different techniques, onlay, inlay, and underlay. The records of 53 consecutive patients with a large midline incisional hernia — 25 women and 28 men, mean age 60.4 (range 28–94) — were reviewed. Polypropylene mesh was implanted using the onlay technique in 13 patients, inlay in 23 patients, and underlay in 17 patients. Either the greater omentum or a polyglactin mesh was interponated between the mesh and the viscera. The records of these 53 patients were reviewed with respect to: size and cause of the hernia, pre- and postoperative mortality and morbidity, with special attention to wound complications. Patients were invited to attend the outpatient clinic at least 12 months after implantation of the mesh for physical examination of the abdominal wall. Postoperative complications occurred in 14 (26.4%) patients. The onlay technique had significantly more complications, as compared to both other techniques. Reherniation occurred in 15 (28.3%) patients. The reherniation rate of the inlay technique was significantly higher than after the underlay technique (44% vs 12%, P=0.03) and tended to be higher than the onlay technique (44% vs 23%, P=0.22). Repair of large midline incisional hernias with the use of a polypropylene mesh carries a high risk of complications and has a high reherniation rate. The underlay technique seems to be the better technique. 相似文献
1 The reproducibility of angiotensin converting enzyme inhibitor induced cough was examined in a double-blind cross over study in patients previously shown to have exhibited this side effect.
2 Ninety-seven patients who had experienced angiotensin converting enzyme inhibitor cough within the last 2 years were challenged with enalapril 20 mg daily for 4 weeks to establish eligibility. Eighty-eight of 97 (91%) patients experienced a repeat of their cough symptoms. Sixty-four patients entered the double-blind part of the study where they were treated with enalapril 20 mg and a renin inhibitor for up to 4 weeks in random order. These periods were separated by a minimum 4 week placebo wash out.
3 Of 59 evaluable patients who received enalapril a second time, 37 (62.7%) experienced cough again. Of 62 patients on the renin inhibitor 16 (25.8%) experienced cough, however as it was not equi-efficacious to enalapril no valid comparison could be made.
4 Angiotensin converting enzyme inhibitor cough is not reproducible within patients, as other factors are involved in the aetiology. Objective testing with blinded assessment together with symptom reporting, would give a more accurate measure of the incidence, and mechanism of this side effect.
The authors report the clinical and laboratory findings of a patient who had severe immune hemolytic anemia due to hydrochlorothiazide (HCTZ). In this case, the HCTZ antibody reacted not only with other thiazide and thiazide-like drugs, but also with a chemically unrelated diuretic, ethacrynic acid. These results indicate that HCTZ antibody activity is not restricted solely to the thiazides and imply that therapy with any of the reactive drugs would be contraindicated for this patient. The serologic screening for drug reactivity may be useful for selecting alternative therapy for patients with drug-induced immune hemolytic anemia. 相似文献
Small single-institutional studies performed prior to the introduction of organ allocation using the Model for End-Stage Liver Disease (MELD) suggest that early airway extubation of liver transplant recipients is a safe practice. We designed a multicenter study to examine adverse events associated with early extubation in patients selected for liver transplantation using MELD score. A total of 7 institutions extubated all patients meeting study criteria and reported adverse events that occurred within 72 hours following surgery. Adverse events were uncommon: occurring in only 7.7% of 391 patients studied. Most adverse events were pulmonary or surgically related. Pulmonary complications were usually minor, requiring only an increase in ambient oxygen concentration. The majority of surgical adverse events required additional surgery. Analysis of a limited set of perioperative variables suggest that blood transfusions and technical factors were associated with an increased risk of adverse events. In conclusion, while early extubation appears to be safe under specified circumstances, there are performance differences between institutions that remain to be explained. 相似文献