Moderate sedatives have been increasingly used to improve patient comfort during flexible bronchoscopy (FB). However, routine use of moderate sedation during FB is controversial because its efficacy and safety are not well established.This study aims to evaluate the efficacy and safety of moderate sedation during FB.A search was made of Medline, EMBASE, and the Cochrane Library to May 2014.Randomized controlled trials (RCTs) and quasi-RCTs were included.The main analysis was designed to examine the efficacy of moderate sedation during FB in sedation than no-sedation.The willingness to repeat FB was significantly more in sedation than no-sedation (odds ratio [OR] 2.30; 95% confidence interval [CI] 1.11–4.73; P = 0.02; I2 = 22.5). The duration of FB was shorter in sedation group than no-sedation group (standardized mean difference [SMD] −0.21; 95% CI −0.38 to −0.03; P = 0.02; I2 = 78.3%). Event of hypoxia was not significantly different between sedation and no-sedation groups (OR 0.86; 95% CI 0.42–1.73; P = 0.67; I2 = 0%). The SpO2 during procedure was not different between sedation and no-sedation groups (SMD −0.14; 95% CI −0.37 to 0.08; P = 0.21; I2 = 49.9%). However, in subgroup analysis without supplemental oxygen, the SpO2 was significantly lower in sedation than no-sedation group (SMD −0.45; 95% CI −0.78 to −0.11; P = 0.01; I2 = 0.0%).According to this meta-analysis, moderate sedation in FB would be useful in patients who will require repeated bronchoscopies as well as safe in respiratory depression. To our knowledge, although the various sedative drugs are already used in the real field, this analysis was the first attempt to quantify objective results. We anticipate more definite and studies designed to elucidate standardized outcomes for moderate sedation in FB. 相似文献
Platelet function has been described by many laboratory assays, and PL-11 is a new point-of-care platelet function analyzer based on platelet count drop method, which counts platelet before and after the addition of agonists in the citrated whole blood samples. The present study sought to compare PL-11 with other three major more established assays, light transmission aggregometry (LTA), VerifyNow? aspirin system and thromboelastography (TEG), for monitoring the short-term aspirin responses in healthy individuals. Ten healthy young men took 100?mg/d aspirin for 3-day treatment. Platelet function was measured via PL-11, LTA, VerifyNow and TEG, respectively. The blood samples were collected at baseline, 2 hour, 1 day during the aspirin treatment and 1 day, 5?±?1 days, 8?±?1 days after the aspirin withdrawal. Moreover, 90 additional healthy subjects were recruited to establish a reference range for PL-11. Platelet function of healthy subjects decreased significantly 2 hours after 100?mg/d aspirin intake and began to recover during 4–6 days after the aspirin withdrawal. Correlations between methods were PL-11 vs. LTA (r?=?0.614, p?<?0.01); PL-11 vs. VerifyNow (r?=?0.829, p?<?0.01); PL-11 vs. TEG (r?=?0.697, p?<?0.001). There was no significant bias between PL-11 and LTA at baseline (bias?=?1.94%, p?=?0.804) using Bland-Altman analysis, while the data of PL-11 were significantly higher than LTA (bias?=?24.02%, p?<?0.001) during the aspirin therapy. The reference range for PL-11 in healthy young individuals was from 66.8 to 90.5% (95%CI). When aspirin low-responsiveness was defined as LTA?>?20%, the cut-off values for each method were, respectively: PL-11?>?50%, VerifyNow?>?533 ARU, TEG?>?60.2%. The results of different platelet function assays were uninterchangeable for monitoring aspirin response and correlations among them were also varied. Correlations among PL-11 and other three major assays suggested the ability of PL-11 to assess the treatment effects of aspirin. But a large cohort study is needed to confirm the cut-off value of aspirin response detected by PL-11. 相似文献
Objective: To evaluate the long-term clinical effect of high-intensity focussed ultrasound (HIFU) as a non-invasive modality for ablation of abdominal wall endometriosis (AWE) foci.
Methods: All women who were diagnosed with cutaneous endometriosis and underwent HIFU ablation and 4-year follow-up were included. Patient symptoms, imaging performed, HIFU ablation, recurrence, lesion location, size and number were collected and analyzed.
Results: A total of 51 women with 57 painful abdominal wall masses with a median volume of 4.00?cm3 and a mean age of 30.5±2.12 years were treated with HIFU. The main symptoms were a palpable painful abdominal mass (93%), protrusion of the skin (28.1%, 16) or lack of protrusion of the skin (71.9%, 41). Ultrasound was initially performed in 100% (51) of women, whereas 6% (3) required MRI examinations to distinguish the features and range of the masses. Ablation was performed with a median 300?s of sonication time, 40?min treatment time, 150?W of power and 41800?J of total energy to treat lesions that were a median volume of 3.83?cm3. No severe complications occurred, except in one patient with a first-degree skin burn, during the 48-month follow-up period. The pooled recurrence of cutaneous endometriosis occurred in 3.9% (2) of women.
Conclusion: The diagnosis of AWE should be confirmed with imaging of the lesion number, location, size and features before HIFU ablation. HIFU should be the first choice for the treatment of AWE as it is a non-invasive method, with high efficiency and safety and rapid postoperative recovery. 相似文献
目的:系统评价沙利度胺(thalidomide,TLD)联合肝动脉化疗栓塞术(transcatheter arterial chemoembolization,TACE)治疗原发性肝癌(primary hepatic carcinomas,PHC)的疗效和安全性.方法:计算机检索Cochrane Library(2014年第3期)、Web of Science(1986/2014-03)、Pub Med(1966/2014-03)、CNKI(1917/2014-03)、维普(1989/2014-03)、万方数据库(1998/2014-03),收集所有TLD联合TACE治疗PHC的随机对照试验.由两名评价员严格按照纳入标准选择文献,提取资料,并参照Cochrane系统评价的要求,对选择纳入的随机对照试验进行方法学质量评估后,采用Cochrane协作网提供的Rev Man 5.2软件对总有效率、疾病控制率、生活质量KPS评分、不同年限生存率、甲胎蛋白的变化、血管内皮生长因子(vascular endothelial growth factor,VEGF)的变化及不良反应发生率进行Meta分析.结果:最终纳入22项随机对照试验,包括1590例PHC患者,Meta分析结果显示,TLD联合TA C E组治疗P H C的总有效率(R R合并=1.29,95%C I:1.15-1.44)、疾病控制率(R R合并=1.27,95%CI:1.16-1.39)、生活质量KPS评分(MD合并=9.23,95%CI:6.90-11.55)、半年生存率(RR合并=1.10,95%C I:1.01-1.20)、1年生存率(RR合并=1.25,95%C I:1.13-1.39)、2年生存率(RR合并=1.45,95%CI:1.18-1.78)、3年生存率(R R合并=1.7 0,9 5%C I:1.1 6-2.5 0)、V E G F水平的变化(M D合并=-123.64,95%C I:-143.72--103.55)优于单纯TACE组,差异有统计学意义(均P0.05);不良反应发生率:在药物性皮疹发生率方面,TLD联合TACE组明显高于单纯TACE组,差异有统计学意义(RR=4.50,95%CI:2.34-8.64,P0.00001);在减少消化系应发生率(RR=1.08,95%CI:0.93-1.25)、降低骨髓抑制发生率(RR=1.12,95%CI:0.82-1.52)、降低肝功能异常发生率方面(R R=1.00,95%C I:0.72-1.39),T L D联合TA C E组与单纯TA C E组相近似,差异无统计学意义(均P0.05).结论:目前研究显示,与单纯TACE疗法相比,TLD联合TACE治疗PHC在总有效率、疾病控制率、生活质量KPS评分、半年生存率、1、2、3年生存率、降低V E G F方面具有明显的优势,但在安全性方面,TLD联合TACE组在药物性皮疹发生率方面明显高于单纯TACE组,而在消化系反应、骨髓抑制率、肝功能异常方面与单纯TACE组相似. 相似文献
BackgroundHepatopancreatobiliary (HPB) surgery fellowship training has multiple paths. Prospective trainees and employers must understand the differences between training pathways. This study examines self-reported fellowship experiences and current scope of practice across three pathways.MethodsAn online survey was disseminated to 654 surgeons. These included active Americas Hepato-Pancreato-Biliary Association (AHPBA) members and recent graduates of HPB, transplant–HPB and HPB–heavy surgical oncology fellowships.ResultsA total of 416 (64%) surgeons responded. Most respondents were male (89%) and most were practising in an academic setting (83%). 290 (70%) respondents underwent formal fellowship training. Although fellowship experiences varied, current practice was largely similar. Minimally invasive surgery (MIS) and ultrasound were the most commonly identified areas of training deficiencies and were, respectively, cited as such by 47% and 34% of HPB-, 49% and 50% of transplant-, and 52% and 25% of surgical oncology-trained respondents. Non-HPB cases performed in current practice included gastrointestinal (GI) and general surgery cases (56% and 49%, respectively) for HPB-trained respondents, transplant and general surgery cases (87% and 21%, respectively) for transplant-trained respondents, and GI surgery and non-HPB surgical oncology cases (70% and 28%, respectively) for surgical oncology-trained respondents.ConclusionsFellowship training in HPB surgery varies by training pathway. Training in MIS and ultrasound is deficient in each pathway. The ultimate scope of non-transplant HPB practice appears similar across training pathways. Thus, training pathway choice is best guided by the training experience desired and non-HPB components of anticipated practice. 相似文献