Previously, the lower generation (DAB 8-generation 2 and DAB 16-generation 3) polypropylenimine dendrimers have been shown to be effective gene delivery systems in vitro. In the current work, we sought to: (a) test the effect of the strength of the carrier, DNA electrostatic interaction on gene transfer and (b) to study the in vivo gene transfer activity of these low molecular weight (<1687 Da) non-amphiphilic plain and quaternary ammonium gene carriers. Towards this aim, methyl quaternary ammonium derivatives of DAB 4 (generation 1), DAB 8, DAB 16 and DAB 32 (generation 4) were synthesised to give Q4, Q8, Q16 and Q32, respectively. Quaternisation of DAB 8 proved to be critical in improving DNA binding, as evidenced by data from the ethidium bromide exclusion assay and dendrimer-DNA colloidal stability data. This improved colloidal stability had a major effect on vector tolerability, as Q8-DNA formulations were well tolerated on intravenous injection while a similar DAB 8-DNA dose was lethally toxic by the same route. Quaternisation also improved the in vitro cell biocompatibility of DAB 16-DNA and DAB 32-DNA dendrimer complexes by about 4-fold but not that of the lower generation DAB 4-DNA and DAB 8-DNA formulations. In contrast to previous reports with non-viral gene delivery systems, the intravenous administration of DAB 16-DNA and Q8-DNA formulations resulted in liver targeted gene expression as opposed to the lung targeted gene expression obtained with the control polymer-Exgen 500 [linear poly(ethylenimine)] and a lung avoidance hypothesis is postulated. We conclude that the polypropylenimine dendrimers are promising gene delivery systems which may be used to target the liver and avoid the lung and also that molecular modifications conferring colloidal stability on gene delivery formulations have a profound effect on their tolerability on intravenous administration. 相似文献
Background: Recent reports indicate increased incidence of Clostridium botulinum infections, particularly among drug abusers and tissue allograft recipients. Botulinum toxin also has potential application in biochemical warfare. The neurotoxin-induced paralysis often requires mechanical ventilation with and without muscle relaxants. The authors investigated the long-term effects of botulinum toxin on muscle function, expression of nicotinic acetylcholine receptors (nAChRs), and their interaction with muscle relaxant, atracurium.
Methods: Rats (n = 30) were injected with varying doses (0.625, 2.5, and 10 U) of botulinum toxin into the tibialis muscle. Control animals (n = 9) received an equivalent volume of saline. At 128 days after injection, neuromuscular function, pharmacodynamics of atracurium, and nAChRs were evaluated.
Results: Nerve-evoked tensions, including tetanic tension and muscle mass, were decreased on the toxin-injected side in a dose-dependent manner relative to saline-injected controls as well as the contralateral side. Specific muscle tension and specific tetanic muscle tension (tensions/muscle mass) were not reduced. The ED10 of atracurium was reduced, the ED50 was unchanged, and the ED90 was increased in the highest (10-U) dose of toxin group. The atracurium plasma concentration to maintain a steady state 50% paralysis was significantly reduced in the 10-U toxin group. The nAChR concentrations in the tibialis muscle were significantly increased in a dose-dependent manner in all experimental groups. 相似文献
BACKGROUND: Our aims in the present study were to estimate the influences of pain and urinary symptoms on quality of life, and to determine which of these two variables has the most predictive power with respect to quality of life in young men with chronic prostatitis-like symptoms. METHODS: Chronic prostatitis-like symptoms were measured by the National Institutes of Health-Chronic Prostatitis Symptom Index. Of the 28,841 men aged 20 years who lived in the study community, 18,495 men (a response rate 64.1%) agreed to participate in the study. A total of 1057 men who complained of symptoms indicative of chronic prostatitis were included in the study. The influences of pain and urinary symptoms on quality of life were determined using logistic regression analysis. The receiver operating characteristic (ROC) curve was used to estimate the predictive ability of each of these variables with respect to quality of life. RESULTS: Results from multivariate analysis showed that both pain and urinary symptoms were associated with an increased likelihood of impaired quality of life, although pain contributed more to a reduced quality of life than urinary symptoms. Relative to men who experienced mild pain, men who experienced moderate pain had a 3.9-fold risk of poor quality of life (odds ratio [OR], 3.87; 95% confidence interval [CI], 2.86-5.23; P < 0.001) and those who experienced severe pain had a 15.7-fold risk of reduced quality of life (OR, 15.68; 95% CI, 6.59-37.35; P < 0.001). Moderate urinary symptoms were associated with a 1.4-fold risk of bother (OR, 1.41; 95% CI, 1.01-1.99; P < 0.001) and severe urinary symptoms were associated with 2.4-fold risk (OR, 2.39; 95% CI, 1.37-4.12; P < 0.001), relative to mild urinary symptoms. Comparison of the effects of pain and urinary symptoms showed that pain severity had the most predictive power for bother, quality of life, and quality-of-life impact. The areas under the ROC curves for bother, quality of life, and quality-of-life impact were 71.3%, 69.3% and 72.5%, respectively. CONCLUSION: Urinary symptoms and pain might be associated with an increased likelihood of impaired quality of life in young men with chronic prostatitis-like symptoms. In addition, our findings suggest that pain severity is the most influential variable for determining quality of life in this population. 相似文献
Self-etching primers have recently been introduced to simplify the orthodontic bonding process. The aim of this study was to compare the effectiveness of such a product with conventional 2-stage etching and priming with 37% o-phosphoric acid and a conventional unfilled primer. Twenty consecutive patients having orthodontic bonds placed were selected to participate in this cross-mouth control study. Diagonally opposite quadrants were randomly allocated to either the self-etching primer group or the conventional etching and priming group. A total of 364 teeth were bonded with a light-cured diacrylate adhesive; bond failures were then monitored over 6 months. There were 20 bond failures (10.99%) in the self-etching primer group and 9 bond failures (4.95%) in the conventional etch and priming group over this period. The results were analyzed with the McNemar test and 95% confidence interval. The difference between the failure proportions was -0.06 with an associated 95% confidence interval of -0.121 to 0.001. This study produced weak evidence to suggest that bond failures with a self-etching primer will be higher than those with conventional etching and priming. This increased likelihood of bond failure must be weighed against the time advantage of the self-etching primer when used at the initial bonding appointment. 相似文献