首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   68篇
  免费   2篇
儿科学   5篇
妇产科学   17篇
临床医学   2篇
神经病学   8篇
特种医学   1篇
外科学   2篇
预防医学   33篇
药学   1篇
肿瘤学   1篇
  2023年   1篇
  2021年   4篇
  2020年   1篇
  2019年   4篇
  2018年   5篇
  2017年   1篇
  2015年   1篇
  2014年   5篇
  2013年   4篇
  2012年   6篇
  2011年   4篇
  2010年   2篇
  2009年   4篇
  2008年   5篇
  2007年   2篇
  2006年   4篇
  2005年   3篇
  2004年   2篇
  2003年   1篇
  2000年   3篇
  1999年   5篇
  1998年   1篇
  1995年   2篇
排序方式: 共有70条查询结果,搜索用时 31 毫秒
1.
Maternal and Child Health Journal - To describe characteristics and outcomes of Group Well-Child Care programs and provide recommendations for future research. Informed by Preferred Reporting Items...  相似文献   
2.
Reaction times (RT) during the Sternberg memory paradigm generally increase with memory set size, but do not differ for positive and negative probe stimuli. Sternberg proposed that this indicated that short-term memory (STM) scanning is both exhaustive and serial. However, this notion has received much criticism, primarily because RT must also reflect response selection factors. Magnetoencephalographic (MEG) recordings of auditory alpha-suppression have previously demonstrated that suppression duration is correlated with set size, potentially providing a physiological index of memory scanning time related specifically to sensory cortices. The current study expands earlier research into this metric by separately analyzing positive and negative probes. Thirteen normal adults participated in an auditory Sternberg paradigm. Pure tones were presented in memory set/probe combinations where the probe had a 50 percent chance of being within the memory set, and RT and accuracy were measured. Magnetic alpha-band activity (8-12 Hz) was quantified for pre- and post-stimulus regions. Although RT did not differ for positive and negative probes, alpha-suppression duration was greater for negative probes than positive ones, potentially indicating that scanning time was slightly faster in the positive condition. This may indicate that STM scanning is serial, but self-terminates when matching occurs.  相似文献   
3.
4.
5.
Objectives. We assessed whether living in counties with Title X clinics and increased use of long-acting reversible contraception (LARC) in Colorado are associated with decreased risk of adverse birth outcomes.Methods. We linked Title X clinic counties to the Colorado birth data set by using the mother’s county of residence. We compared low birth weight (LBW) and preterm birth (PTB) in 2008 and 2012, in counties with and without Title X clinics. We compared the relationship between LARC use and the incidence of LBW or PTB in 2012 for women living in counties with Title X clinics.Results. For women living in counties with Title X clinics, the odds of PTB were significantly lower in 2012 compared with 2008 (odds ratio = 0.85; 95% confidence interval = 0.81, 0.89; interaction P = .02). For women living in Title X clinic counties in 2012, a higher proportion of LARC use (> 12.4%) was significantly associated with decreased risk of PTB (P = .02) compared with a low proportion of LARC use (≤ 4.96%).Conclusions. Improved access to family planning services and increased use of LARC are associated with lower risk of PTB.Unintended pregnancy is a significant public health issue in the United States. According to the most recent published estimates, 51% of pregnancies in the United States were unintended, and 60% of unintended pregnancies resulted in a live birth.1 Unintended pregnancies are associated with increased risk of adverse pregnancy outcomes, such as preterm birth (PTB) and delivery of low–birth weight (LBW) infants.2–8 In a large systematic review, Shah et al. reported increased odds of PTB (odds ratio [OR] = 1.31; 95% confidence interval [CI] = 1.09, 1.58) and LBW (OR = 1.36; 95% CI = 1.25, 1.48) among unintended pregnancies ending in live birth compared with intended pregnancies.2 The link between unintended pregnancy and poor birth outcomes is likely multifaceted, and may be associated with maternal socioeconomic risk factors, inadequate prenatal care, and preconceptual and prenatal maternal behavioral risk factors such as smoking and alcohol use.9–11 As part of the national effort to improve overall public health, increasing the proportion of pregnancies that are intended and decreasing the rates of PTB and LBW deliveries are all objectives of the Healthy People 2020 initiative.12In 2008, 37% of live births in Colorado resulted from unintended pregnancies according to the Pregnancy Risk Assessment Monitoring System.13 To address this issue, the Colorado Initiative to Reduce Unintended Pregnancy (Colorado Initiative) was developed and enacted in 2009 with the generous support of an anonymous donor.14 As part of the effort, the Colorado Family Planning Initiative was implemented through the Colorado Department of Public Health and Environment. Two of the primary goals of the initiative were (1) increasing the number of women accessing family planning services and (2) increasing the adoption of long-acting reversible contraceptive (LARC) methods such as intrauterine devices and contraceptive implants.14 Long-acting reversible contraceptive methods are safe and highly effective forms of contraception that have been shown to reduce rates of unintended pregnancy.15–18To help achieve these objectives, the Colorado Initiative provided funding to 28 Title X–funded agencies across the state of Colorado from 2009 to 2013, serving 37 of 64 Colorado counties. Those 37 counties were home to 95% of the state’s low-income population (defined as individuals with incomes at or below 150% of the federal poverty level).14 The locations of Colorado Title X clinics are shown in Figure 1. This distribution of resources in Colorado is important, in light of the known disparities of unintended pregnancy rates for women on the basis of socioeconomic status, age, race/ethnicity, and level of education.1Open in a separate windowFIGURE 1—Counties and locations of Title X clinics: Colorado, 2008 and 2012.The funding for the Colorado Initiative specifically supported the provision of intrauterine devices and contraceptive implants to women seeking care at Title X clinics, training for providers and staff on the counseling and provision of LARC methods, and technical assistance to Title X agencies related to increasing the use of these methods.14 Many of the Title X clinics across the state successfully executed the primary objectives of the Colorado Initiative, resulting in a rise in the total number of clients accessing family planning services per year from 46 201 to 64 148 and the proportion of women choosing LARC methods out of all women using contraception at Title X clinics from 0.8% to 8.6% from 2008 to 2012 (G. Klinger, Colorado Department of Public Health and Environment, e-mail communication, April 1, 2014).Although LARC use is on the rise in the United States, there is little in the published literature demonstrating an association between the use of LARC methods and rates of adverse birth outcomes.19 Given the scale of the Colorado Initiative, there is a unique opportunity to evaluate this possible association. As a result of improved use of family planning services in general and LARC use in particular, we hypothesized the following: (1) there will be a significant decrease in LBW and PTB in Colorado from 2008 to 2012; (2) for women living in Colorado counties in 2012 compared with 2008, LBW and PTB will differ by whether there is a Title X clinic in that woman’s county of residence; and (3) for women living in Colorado counties with Title X clinics in 2012, there will be a significant inverse association between LARC use at Title X clinics and LBW and PTB.  相似文献   
6.

Background:

Minimally invasive surgery has become a standard treatment for endometrial cancer and offers significant benefits over abdominal approaches. There are discrepant data regarding lymphovascular space invasion (LVSI) and positive peritoneal cytology with the use of a uterine manipulator, with previous small-scale studies demonstrating an increased incidence of these prognostically important events. We sought to determine if there was a higher incidence of LVSI in patients who underwent robot-assisted surgery for endometrial cancer.

Methods:

We performed a single-institution review of medical records for patients who underwent open abdominal or robot-assisted hysterectomy for endometrial cancer over a 24-month period. The following data were abstracted: age, tumor grade and stage, size, depth of invasion, LVSI, and peritoneal cytology. For patients with LVSI, slides were reviewed by 2 pathologists for confirmation of LVSI.

Results:

Of 104 patients identified, LVSI was reported in 39 (37.5%) and positive peritoneal cytology in 6 (4.8%). Rates of peritoneal cytology were not significantly different between the 2 groups (odds ratio, 0.55; 95% confidence interval, 0.10–3.17; P = .50). LVSI was reported in significantly fewer robot-assisted hysterectomies than open procedures (odds ratio, 0.39; 95% confidence interval, 0.17–0.92; P = .03). In subgroup analyses restricted to early-stage disease (stage ≤ II), there was no significant difference in LVSI between open and robot-assisted hysterectomies (odds ratio, 0.64; 95% confidence interval, 0.22–1.85; P = .43).

Conclusion:

In this retrospective study, we found that use of a uterine manipulator in robot-assisted surgery did not increase the incidence of LVSI.  相似文献   
7.
8.
PURPOSE: To evaluate whether the presence of metabolic syndrome (MS) in obese adolescents is associated with other comorbidities of obesity METHODS: A total of 85 obese teens (70% female and 30% male) with fasting insulin >25 microU/ml and family history of type 2 diabetes mellitus and/or acanthosis nigricans were studied. Mean age was 15.8 +/- 1.7 years and body mass index (BMI) was 39.3 +/- 6.6 kg/m(2). Of the subjects, 54% were Hispanic and 35% black, 5% white, 5% American Indian, and 1% Asian. Laboratory analysis included fasting lipids, glucose, gamma-glutamyl transpeptidase (GGT), and oral glucose tolerance testing. Additional liver transaminase levels were determined and liver ultrasound (US) was performed to evaluate the presence and severity of fatty liver. RESULTS: All subjects met MS criteria for children for waist circumference, 49% for blood pressure, 54% for high-density lipoprotein, 54% for triglycerides, and 20% for impaired fasting glucose (IFG) or impaired glucose tolerance [IGT]). In all, 47 subjects had three or more MS criteria. BMI was no different between groups with and without MS. Subjects with three or more MS criteria were more likely to have IGT (p = .004), elevated alanine aminotransferase (p = .039), elevated GGT (p = .036), fatty liver on US (p < .001), and more severe fatty liver (p = .001). CONCLUSIONS: Abnormal glucose regulation and evidence of nonalcoholic fatty liver disease (NAFLD) were more common in subjects meeting three criteria for MS than in those meeting fewer criteria. The identification of MS provides value to the primary care provider. Those patients meeting criteria for MS should be evaluated for glucose intolerance and NAFLD.  相似文献   
9.
Teal SB  Sheeder J 《Contraception》2012,85(3):270-274
BackgroundMany professional organizations recommend intrauterine device (IUD) use in adolescents, but data on performance of currently available devices in US teens are scant. We describe IUD continuation, side effect and pregnancy rates in parous adolescents.Study DesignBetween 2002 and 2008, a cohort of 136 young mothers from an adolescent pregnancy/postpartum program received either a CuT380A or LNG-IUS for contraception. A minimum of 2 years postplacement, IUD status was ascertained by records review and phone interviews. Discontinuation, side effect and pregnancy rates by IUD type were calculated and compared.ResultsMean and median survival times were 25.1 and 14.1 months, respectively, and did not differ by IUD type. Twelve-month continuation was 55%. Of the 87 removals, the most common reasons were expulsion (14.2%), pain (12.2%), bleeding (7.4%), pregnancy desire (6.8%) and pregnancy (4.7%), and rates did not differ significantly by IUD type. First-year pregnancy rates with IUD in situ was 6.2% for the CuT380A and 3.7% for the LNG-IUS (p=.5). Rates of removal for bleeding and pain were similar for both devices.ConclusionOver half of parous adolescents who choose IUDs keep them for at least 1 year. Expulsion rates and pregnancy rates are higher than reported in the general population.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号