Post-induction hypotension is common and associated with postoperative complications. We hypothesised that pneumatic leg compression reduces post-induction hypotension in elderly patients undergoing robot-assisted laparoscopic prostatectomy. In this double-blind randomised study, patients were allocated randomly to the pneumatic leg compression group (n = 50) or control (n = 50). In the intervention group, pneumatic leg compression was initiated before induction of anaesthesia. In the control group, pneumatic leg compression was initiated 20 min after anaesthesia induction. The primary outcome was the incidence of post-induction hypotension in these groups. Post-induction hypotension was defined as systolic blood pressure < 90 mmHg during the first 20 min after induction. Haemodynamic variables and area under the curve of post-induction systolic blood pressure over time were assessed. Complications associated with pneumatic leg compression were recorded, including: peripheral neuropathy; compartment syndrome; extensive bullae beneath the leg sleeves; and pulmonary thromboembolism. The incidence of post-induction hypotension decreased in the pneumatic leg compression group compared with that in the control group; 5 (10%) vs. 29 (58%), respectively, p < 0.001. In the pneumatic leg compression group, the lowest systolic, diastolic and mean blood pressures 20 min after induction of anaesthesia were significantly greater than the control group. Pneumatic leg compression resulted in an increased area under the curve of systolic blood pressure in the first 20 min after induction, p = 0.001. There were no pneumatic leg compression-related complications. Pneumatic leg compression reduced post-induction hypotension in elderly patients undergoing robot-assisted laparoscopic prostatectomy, suggesting that it is an effective and safe intervention to prevent post-induction hypotension among elderly patients undergoing general anaesthesia. 相似文献
Etodolac is a nonsteroidal anti-inflammatory drug with selective cyclooxygenase-2 inhibition to treat pain and inflammation associated with osteoarthritis in humans and dogs. The aim of the study was to investigate the pharmacokinetics of etodolac following single oral administration of 200?mg to 10 healthy beagle dogs.
The plasma concentrations of etodolac were detected using liquid chromatography-tandem mass spectrometry. Pharmacokinetic analysis was conducted using the noncompartmental method and modeling approaches.
Etodolac was rapidly absorbed (Tmax?=?0.85?h, Ka?=?1.49?h?1) and slowly eliminated (T1/2?=?39.55?h) following oral administration to the dogs. A two-compartment pharmacokinetic model with first-order absorption and elimination rate constants was successfully explained for the pharmacokinetic aspects of etodolac in dogs. From a Monte Carlo simulation (1000 repetitions), the accumulation index and AUCτ at steady state were predicted as 1.60 [90% confidence intervals (CI), 1.24–2.81] and 408.18?ng·hr/mL [90% CI, 271.26–590.58?ng·hr/mL], respectively.
This study will help to enact a more accurate optimal dosing regimen of etodolac in dogs with osteoarthritis, and may be useful in developing a novel formulation of etodolac for human in the future.
Direct peroral cholangioscopy (POC) using an ultra‐slim upper endoscope is one modality of POC for intraductal endoscopic evaluation and treatment of the bile duct. Choledochoduodenostomy (CDS) is one modality of biliary bypass surgery that provides a new route to the bile duct. We carried out direct POC using an ultra‐slim upper endoscope without the use of accessories in 10 patients (four sump syndromes, three bile duct strictures and three intrahepatic duct stones) previously undergoing surgical CDS. Direct POC was successful in all patients. The use of an intraductal balloon catheter was required in one patient for advancement of the endoscope into the bile duct. Distal bile ducts with sump syndromes were cleared using baskets and water irrigation under direct POC. Cholangiocarcinoma was diagnosed in one patient with hilar bile duct stricture after cholangioscopic evaluation and a targeting forceps biopsy under direct POC. Intrahepatic duct stones were successfully extracted after intraductal fragmentation under direct POC. Oozing bleeding occurred during intraductal lithotripsy but stopped spontaneously. Direct POC using an ultra‐slim upper endoscope without the assistance of accessories can easily be carried out in patients undergoing CDS. 相似文献
A classic pilomatricoma, which usually presents with an asymptomatic, solitary, firm, subcutaneous nodule in the head, neck, or extremities of the paediatric population, is easily diagnosed based on its characteristic clinical and histopathological features. However, its variants often pose particular diagnostic challenges to clinicians due to their rarity and diverse clinicopathological features. We present a new pseudocystic variant, manifesting as solid lesions floating in a fluid‐filled sac. 相似文献
BackgroundIn the field of transplantation, inducing immune tolerance in recipients is of great importance. Blocking co-stimulatory molecule using anti-CD28 antibody could induce tolerance in a rat kidney transplantation model. Myeloid-derived suppressor cells (MDSCs) reveals strong immune suppressive abilities in kidney transplantation. Here we analyzed key genes of MDSCs leading to transplant tolerance in this model.MethodsMicroarray data of rat gene expression profiles under accession number {"type":"entrez-geo","attrs":{"text":"GSE28545","term_id":"28545"}}GSE28545 in the Gene Expression Omnibus (GEO) database were analyzed. Running the LIMMA package in R language, the differentially expressed genes (DEGs) were found. Enrichment analysis of the DEGs was conducted in the Database for Annotation, Visualization and Integrated Discovery (DAVID) database to explore gene ontology (GO) annotation and their Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways. Their protein-protein interactions (PPIs) were provided by STRING database and was visualized in Cytoscape. Hub genes were carried out by CytoHubba.ResultsThree hundred and thirty-eight DEGs were exported, including 27 upregulated and 311 downregulated genes. The functions and KEGG pathways of the DEGs were assessed and the PPI network was constructed based on the string interactions of the DEGs. The network was visualized in Cytoscape; the entire PPI network consisted of 192 nodes and 469 edges. Zap70, Cdc42, Stat1, Stat4, Ccl5 and Cxcr3 were among the hub genes.ConclusionsThese key genes, corresponding proteins and their functions may provide valuable background for both basic and clinical research and could be the direction of future studies in immune tolerance, especially those examining immunocyte-induced tolerance. 相似文献
ObjectiveTo compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS).Materials and MethodsThe Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods. Bland-Altman plots were used to evaluate the agreement between the measurements.ResultsLumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 mm3; 95% confidence interval [CI], 4.9–24.3 mm3); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, −0.7 mm3; 95% CI, −9.1–7.7 mm3). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 mm2; 95% CI, 0.89–1.25 mm2) but not in the larger lumen area group (mean of difference, −0.07 mm2; 95% CI, −0.22–0.08 mm2). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 mm2; 95% CI, 0.27–0.65 mm2) than in that of IVUS and SATM (1.53 mm2; 95% CI, 1.27–1.79 mm2).ConclusionSATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM. 相似文献