首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   43篇
  免费   0篇
儿科学   1篇
口腔科学   20篇
临床医学   11篇
内科学   3篇
皮肤病学   1篇
神经病学   1篇
外科学   1篇
综合类   1篇
预防医学   4篇
  2020年   1篇
  2017年   1篇
  2013年   3篇
  2012年   1篇
  2011年   1篇
  2010年   1篇
  2007年   2篇
  2006年   1篇
  2005年   1篇
  2004年   4篇
  2003年   3篇
  2002年   1篇
  2001年   2篇
  2000年   4篇
  1999年   2篇
  1997年   1篇
  1996年   1篇
  1994年   1篇
  1993年   1篇
  1990年   1篇
  1989年   1篇
  1987年   1篇
  1986年   4篇
  1985年   3篇
  1984年   1篇
排序方式: 共有43条查询结果,搜索用时 31 毫秒
1.
2.
Two studies were conducted to investigate the relative effects of sustained release methylphenidate (Ritalin [SR-20]) and standard methylphenidate (Ritalin, 10 mg, administered twice daily). In the first study, 13 boys with attention deficit disorder participating in a summer treatment program went through a double-blind, within-subject trial of each form of methylphenidate and placebo. Measures of social and cognitive behavior were gathered in classroom and play settings. Although group analyses of the data showed that both drugs were effective and there were few differences between them, standard methylphenidate was superior to SR-20 on several important measures of disruptive behavior. Furthermore, analyses of individual responsivity showed clearly that most boys responded more positively to standard methylphenidate than to SR-20. The second study involved a partially overlapping group of nine boys with attention deficit disorder participating in the same summer treatment program. Also double-blind, within-subject, and placebo controlled, this study tracked the time courses of the two forms of methylphenidate. Both were shown to have similar time courses on the Abbreviated Conners Rating Scale and other measures, but SR-20 had a slower onset than did the standard drug form on a continuous performance task. Effects of SR-20 were still evident eight hours after ingestion.  相似文献   
3.
The virucidal spectrum of a high concentration alcohol mixture (80% ethanol and 5% isopropanol) was determined for a broad series of lipid-enveloped (LE) and non-lipid-enveloped (NLE) viruses covering all relevant blood-borne viruses. LE viruses were represented by human immunodeficiency virus (HIV), bovine viral diarrhoea virus (BVDV), a specific model virus for hepatitis C virus (HCV), pseudorabies virus (PRV), and vaccinia virus. For the NLE viruses hepatitis A virus, canine parvovirus (a model for human parvovirus B19), and reovirus type 3 (Reo-3) were used. PRV, vaccinia, and Reo-3 served as general model viruses. The alcohol mixture was spiked with 5% (v/v) virus, mixed and tested for residual virus after 5 min treatment. Complete clearance (reduction by a factor of >10(6)) was observed for LE viruses, whereas incomplete to insignificant clearance (ranging from no reduction up to a maximum factor of 10(4)) was found for NLE viruses. In a second series of spiking experiments using the LE viruses BVDV, HIV, and PRV, complete clearance (reduction by a factor of >10(6)) was found after 20 s treatment. These data strongly suggest that treatment with a high concentration alcohol mixture has a high virucidal potential in particular for the blood-borne LE-viruses HIV, hepatitis B virus, and HCV. Such mixtures are well suited for rapid and frequent disinfection in dental practice being non-hazardous and non-toxic.  相似文献   
4.
The removal of gutta-percha and sealer from endodontically treated root canals may prompt the use of organic solvents. In the present article a number of possible solvents are described and, based upon the literature, their efficacy is assessed. Some solvents, amongst which chloroform, xylene and halothane are almost equally efficient, although all leave a debris of gutta-percha and sealer in the root canals behind. Only chloroform solves AH26 and most probably AH-plus, but very slowly. Eucalyptol and turpentine oil are slow dissolvers. Orange oil and limonene are promising. The data on other solvents, if candidates at all, are scarce. The choice of a solvent is co-determined by factors such as toxicity and sensitisation, which will be described in a second publication.  相似文献   
5.
This double-blind study used a split-mouth design to investigate the microbiological and clinical effects of 0.2% chlorhexidine enclosed in fixtures. Twelve patients had 46 fixtures implanted. At second-stage surgery, a microbiological sample (baseline sample) of the inner parts of the fixtures was taken. Then, a 0.2% chlorhexidine solution was applied into the inner space of 23 fixtures (test group), and in 23 fixtures saline was applied (control group). Abutments were installed and gingival index, plaque index and crevicular fluid flow were monitored weekly. After 6 weeks, a second microbiological sample of the inner part of the fixtures was taken. At baseline, viable bacteria were detected within 46% of the fixtures. After weeks, bacteria were found in 87% of the fixtures. The numbers of bacteria in the control group were significantly higher than those in the test group. The results indicate that, after first-stage surgery, contamination of the inner spaces of the fixtures is commonplace. Application of a 0.2% chlorhexidine solution at second-stage surgery inhibits growth or acquisition of bacteria in the fixtures. In both test and control groups, the crevicular fluid flow as well as the gingival index decreased during the experimental period. At 4, 5, and 6 weeks after chlorhexidine application, these values in the test group appeared lower, but did not attain statistical significance.  相似文献   
6.
A number of polluting chemicals in the ecosystems must be characterized as hormone disruptors. Among others, male animals appear to become feminized by the action of the so-called pseudo-estrogens and under their influence mens' fertility is said to decrease. Composites and sealants based on Bis-GMA resin may contain bisphenol-A as an impurity and Bis-DMA, from which in saliva bisphenol-A will be formed by hydrolytic degradation. Therefore, in extreme circumstances a weak estrogenic effect is not impossible on the short-term. However, the amounts of these probably not very potent estrogenic compounds are small, thereby resulting in a tolerable risk on the short term. Long-term-effects and synergism with pseudo-estrogens from other sources prompt further studies in order to verify the safety of the Bis-GMA containing products.  相似文献   
7.
8.
PURPOSE: The purpose of this study was to evaluate three alignment systems based on two alignment theories that can be utilized in the fabrication of monolimb prostheses that have acceptable alignment. A second goal was to assess the feasibility of technology transfer for providing prosthetic services to remote areas of landmine-affected countries. METHOD: Five prosthetists and five healthy transtibial amputees participated in the study. Each prosthetist was trained and then used each of the three systems to capture alignment measurements for one subject. Three monolimbs identified as X, Y and Z were fabricated for each subject and assessed during clinical static and dynamic gait conditions. Training materials and methods were also evaluated. RESULTS: All three systems captured acceptable alignments fairly well, although the two systems that incorporated weight-bearing into the alignment process had slightly better outcomes. Each system has its own advantages in terms of ease of use, required equipment, and ease of technology transfer. CONCLUSION: All three systems have the potential for application in outreach prosthetic services and warrant continued evaluation. Minor changes need to be incorporated into the alignment systems and procedures to make them easier to use and more effective.  相似文献   
9.
Purpose. The purpose of this study was to evaluate three alignment systems based on two alignment theories that can be utilized in the fabrication of monolimb prostheses that have acceptable alignment. A second goal was to assess the feasibility of technology transfer for providing prosthetic services to remote areas of landmine-affected countries.

Method. Five prosthetists and five healthy transtibial amputees participated in the study. Each prosthetist was trained and then used each of the three systems to capture alignment measurements for one subject. Three monolimbs identified as X, Y and Z were fabricated for each subject and assessed during clinical static and dynamic gait conditions. Training materials and methods were also evaluated.

Results. All three systems captured acceptable alignments fairly well, although the two systems that incorporated weight-bearing into the alignment process had slightly better outcomes. Each system has its own advantages in terms of ease of use, required equipment, and ease of technology transfer.

Conclusion. All three systems have the potential for application in outreach prosthetic services and warrant continued evaluation. Minor changes need to be incorporated into the alignment systems and procedures to make them easier to use and more effective.  相似文献   
10.
Dental Unit Water Systems (DUWS) are used in dental practices to provide water for cooling of dental equipment and irrigation of the oral cavity. However, they have been demonstrated to be contaminated with micro-organisms. There are currently no European Union (EU) Commission guidelines for the microbial quality of water discharged by DUWS. This study was part of an EU research programme to investigate the microbial contamination of DUWS in general dental practice (GDP) in the UK, Denmark, Germany, The Netherlands, Ireland, Greece and Spain. OBJECTIVE: To undertake a questionnaire survey on the type of DUWS in use and determine the attitude of GDPs to the risk of microbial infection from DUWS. MATERIALS AND METHODS: The questionnaire was written and translated into the language of each country before being posted to each participating dentist. Dentists were asked to complete the questionnaire survey and return it by post. RESULTS AND CONCLUSIONS: The major findings were that the majority of dentists did not clean, disinfect or determine the microbial load of their DUWS, and that dentists would welcome regular monitoring and advice on maintaining their DUWS; the introduction of guidelines; and recommendations on controlling the microbial load of DUWS.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号