Background and purpose — Total ankle arthroplasties (TAAs) have larger revision rates than hip and knee implants. We examined the survival rates of our primary TAAs, and what different factors, including the cause of arthritis, affect the success and/or revision rate.Patients and methods — From 2004 to 2016, 322 primary Hintegra TAAs were implanted: the 2nd generation implant from 2004 until mid-2007 and the 3rd generation from late 2007 to 2016. A Cox proportional hazards model evaluated sex, age, primary diagnosis, and implant generation, pre- and postoperative angles and implant position as risk factors for revision.Results — 60 implants (19%) were revised, the majority (n = 34) due to loosening. The 5-year survival rate (95% CI) was 75% (69–82) and the 10-year survival rate was 68% (60–77). There was a reduced risk of revision, per degree of increased postoperative medial distal tibial angle at 0.84 (0.72–0.98) and preoperative talus angle at 0.95 (0.90–1.00), indicating that varus ankles may have a larger revision rate. Generation of implant, sex, primary diagnosis, and most pre- and postoperative radiological angles did not statistically affect revision risk.Interpretation — Our revision rates are slightly above registry rates and well above those of the developer. Most were revised due to loosening; no difference was demonstrated with the 2 generations of implant used. Learning curve and a low threshold for revision could explain the high revision rate.Arthritis in the ankle often develops earlier than in the hip or knee, and 70% have a traumatic etiology (Saltzman et al. 2005, Brown et al. 2006). Total ankle arthroplasty (TAA) can be indicated for severe arthritis in the ankle joint, but the anatomical preconditions, like a small surface area and high stress from compression and torque (Bouguecha et al. 2011, Kakkar and Siddique 2011), makes it less durable than hip and knee prosthetics. The Hintegra TAA, a 3-component mobile bearing, uncemented implant (Hintermann et al. 2004) is widely used and results from the development center demonstrate survival rates of 94% and 84% after 5 and 10 years’ follow-up (Barg et al. 2013). This is considerably more than the survival rates from national registries. Labek et al. (2011) demonstrated that development centers report only half of the revision rate that can be found in the few existing national registers. In a systematic review of primary Agility total ankle arthroplasty (DePuy Synthes Orthopedics, Warsaw, IN, USA), the author (Roukis 2012) found that the incidence of complications increased from 7% to 12%, in studies where the inventor was excluded. Similar results were found by Prissel and Roukis (2013), who found an increased incidence of complications from 6% to 13% in studies where the inventor or faculty consultants were excluded. These studies indicated the risk of selection (inventor) and publication (conflict of interest) bias.Planning and surgical technique, including significant experience, are mandatory for a successful outcome. The better result from development centers may reflect, besides the above-mentioned bias, that there is a long learning curve and that the indication for revision surgery varies.We examined the survival rates of primary Hintegra TAAs performed at Hvidovre Hospital, with revision rate as outcome. We report primary diagnosis for primary TAA and examine whether sex, generation of the implant, preoperative angles and implant position affect the revision rate. 相似文献
BackgroundA venous leg ulcer is a chronic leg wound caused by poor venous blood circulation in the lower limbs. It is a recurring condition causing pain, malodour, reduced mobility, and depression. Randomised controlled trials evaluating treatments for venous leg ulcers provide important evidence to inform clinical decision-making. However, for findings to be useful, outcomes need to be clinically meaningful, consistently reported across trials, and fully reported. Research has identified the large number of outcomes reported in venous leg ulcer trials, impacting both synthesis of results, and clinical decision-making. To address this, a core outcome set will be developed. A core outcome set is an agreed standardised set of outcomes which should be, as a minimum, measured and reported in all trials which evaluate treatment effectiveness for a given indication. A core outcome set has the potential to reduce research waste, improve the utility of RCTs, reduce reporting bias, facilitate treatment comparisons across different sources of evidence and expedite the production of systematic reviews, meta-analyses and evidence-based clinical guidelines.AimThe aim of this project is to develop a core outcome set for research evaluating the effectiveness of interventions for treating venous leg ulceration.MethodsThrough a scoping review of the literature on venous leg ulceration, we will firstly identify a list of candidate outcome domains (broad categories in relation to what is being measured) from randomised controlled trials and qualitative research, and outcomes (specific methods in relation to what is being measured). In two further stages, we will use the resulting lists of outcome domains and outcomes to design two online surveys. A range of stakeholders will be invited to participate in the surveys and they will be asked to indicate which outcome domains and outcomes are most important and should be considered as core in future research reports. 相似文献
Physicians treating nonvalvular atrial fibrillation (AF) assess stroke and bleeding risks when deciding on anticoagulation. The agreement between empirical and physician-estimated risks is unclear. Furthermore, the association between patient and physician sex and anticoagulation decision-making is uncertain.
Methods
We pooled data from 2 national primary care physician chart audit databases of patients with AF (Facilitating Review and Education to Optimize Stroke Prevention in Atrial Fibrillation and Coordinated National Network to Engage Physicians in the Care and Treatment of Patients with Atrial Fibrillation Chart Audit) with a combined 1035 physicians (133 female, 902 male) and 10,927 patients (4567 female and 6360 male).
Results
Male physicians underestimated stroke risk in female patients and overestimated risk in male patients. Female physicians estimated stroke risk well in female patients but underestimated the risk in male patients. Risk of bleeding was underestimated in all. Despite differences in risk assessment by physician and patient sex, > 90% of patients received anticoagulation across all subgroups. There was modest agreement between physician estimated and calculated (ie, CHADS2 score) stroke risk: Kappa scores were 0.41 (0.35-0.47) for female physicians and 0.34 (0.32-0.36) for male physicians.
Conclusions
Our study is the first to examine the association between patient and physician sex influences and stroke and bleeding risk estimation in AF. Although there were differences in agreement between physician estimated stroke risk and calculated CHADS2 scores, these differences were small and unlikely to affect clinical practice; further, despite any perceived differences in the accuracy of risk assessment by sex, most patients received anticoagulation. 相似文献
We have recently shown that human epididymis protein 4 (HE4) levels correlate with the severity of cystic fibrosis (CF) lung disease. However, there are no data on how HE4 levels alter in patients receiving CFTR modulating therapy.
Methods
In this retrospective clinical study, 3 independent CF patient cohorts (US-American: 29, Australian: 12 and Irish: 19 cases) were enrolled carrying at least one Class III CFTR CF-causing mutation (p.Gly551Asp) and being treated with CFTR potentiator ivacaftor. Plasma HE4 was measured by immunoassay before treatment (baseline) and 1–6?months after commencement of ivacaftor, and were correlated with FEV1 (% predicted), sweat chloride, C-reactive protein (CRP) and body mass index (BMI).
Results
After 1?month of therapy, HE4 levels were significantly lower than at baseline and remained decreased up to 6?months. A significant inverse correlation between absolute and delta values of HE4 and FEV1 (r?=??0.5376; P?<?.001 and r?=??0.3285; P?<?.001), was retrospectively observed in pooled groups, including an independent association of HE4 with FEV1 by multiple regression analysis (β?=??0.57, P?=?.019). Substantial area under the receiver operating characteristic curve (ROC-AUC) value was determined for HE4 when 7% mean change of FEV1 (0.722 [95% CI 0.581–0.863]; P?=?.029) were used as classifier, especially in the first 2?months of treatment (0.806 [95% CI 0.665–0.947]; P?<?.001).
Conclusions
This study shows that plasma HE4 levels inversely correlate with lung function improvement in CF patients receiving ivacaftor. Overall, this potential biomarker may be of value for routine clinical and laboratory follow-up of CFTR modulating therapy. 相似文献
Background: Previous studies have shown that propofol and sevoflurane enhance the function of [gamma]-aminobutyric acid type A (GABAA) receptors. However, it is not known whether these two drugs modulate the same molecular pathways. In addition, little is known about receptor function in the presence of both propofol and sevoflurane. The aim of this study was to better understand the interactions of propofol and sevoflurane with the GABAA receptor.
Methods: Wild-type [alpha]1, [beta]2, [gamma]2s GABAA receptor subunit complementary DNAs were transfected into human embryonic kidney cells grown on glass coverslips using a calcium phosphate transfection method. After transfection (36-72 h), cells were whole cell patch clamped and exposed to combinations of the following: 0.3-1,000 [mu]m [gamma]-aminobutyric acid (GABA), 0-10 [mu]m propofol, and 0-1,650 [mu]m sevoflurane. Chemicals were delivered to the cells using two 10-channel infusion pumps and a rapid solution exchanger.
Results: Both propofol and sevoflurane alone enhanced the amplitude of GABAA receptor responses to submaximal concentrations of GABA in a dose-dependent manner. The enhancement was underpinned by an increase in the apparent affinity of the receptor for GABA. Coapplication of both anesthetics further enhanced the apparent affinity of the receptor for GABA. 相似文献
Electrophysiologic technology developed over the past 20 years has improved the life expectancy of patients who have survived sudden cardiac death events. Use of an implantable cardioverter defibrillator (ICD) continues to increase as more indications for the device are researched. Patients with ICDs will be cared for in the postanesthesia care unit following cardiac and noncardiac surgery and require PACU nurses to be knowledgeable about this advanced and changing technology as well as provide for emotional and psychological needs. 相似文献