首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   26篇
  免费   11篇
耳鼻咽喉   5篇
儿科学   1篇
基础医学   3篇
口腔科学   4篇
神经病学   3篇
特种医学   5篇
外科学   9篇
综合类   1篇
药学   1篇
肿瘤学   5篇
  2020年   1篇
  2019年   1篇
  2017年   1篇
  2016年   1篇
  2015年   2篇
  2014年   3篇
  2013年   2篇
  2012年   3篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2008年   2篇
  2007年   5篇
  2005年   3篇
  2003年   1篇
  2002年   3篇
  2001年   3篇
  1997年   1篇
  1996年   2篇
排序方式: 共有37条查询结果,搜索用时 31 毫秒
1.
The aim was to develop a comprehensive screening instrument for evaluation of orofacial dysfunction that was easy to perform for different health professionals without special equipment. The Nordic Orofacial Test--Screening (NOT-S), consisting of a structured interview and clinical examination,was developed with a picture manual illustrating the different tasks in the examination. It was first tested in a Swedish version, and later translated to other Nordic languages, and to English. The interview reflected six domains, (I) Sensory function, (II) Breathing, (III) Habits, (IV) Chewing and swallowing, (V) Drooling, and (VI) Dryness of the mouth, and the examination included six domains representing (1) The face at rest, and tasks regarding (2) Nose breathing, (3) Facial expression, (4) Masticatory muscle and jaw function, (5) Oral motor function, and (6) Speech. One or more "yes" for impairment in a domain resulted in one point (maximum NOT-S score 12 points). The mean NOT-S score (+/- SD) in 120 patients (3-86 yr), referred to five centers for specialized dental care or speech and language pathology in Sweden, Norway and Denmark, was 4.1 +/- 2.6, and 0.4 +/- 0.6 in 60 control subjects (3-78 yr). The screening was easy to administer and the time spent 5-13 min. The scores from the clinic-referred sample differed significantly from the controls, and the sensitivity of the screening was 0.96 and specificity 0.63. Repeated evaluations of videotapes of 200 patients by 3 examiners, speech-language pathologists and dentists, with at least two-week intervals, showed inter- and intraexaminer agreement on the points given in the domains at respectively 83% and 92-95% which increased after recalibration to 85% and 95-99%. Kappa values for interexaminer agreement on the NOT-S scores were 0.42-0.44 (i.e. fair), and the method error was 5.3%. To conclude, NOT-S gave a reliable and valid screening for orofacial dysfunction.  相似文献   
2.
Myotonic dystrophy or dystrophia myotonica (DM) is a hereditary neuromuscular multisystem disease with a varying clinical expressivity and severity. The objective of this study was to assess the oral health in children with myotonic dystrophy and to compare it with a control group. Fifty-six DM patients, aged 2.7-18.0 yr, were compared with age- and gender-matched control patients with respect to caries, plaque, and gingivitis. Oral function and signs of temporomandibular dysfunction (TMD) were assessed, and the ability to co-operate in dental treatment was estimated. Questionnaires concerning eating habits, dental care, traumatic injuries to teeth, and orofacial function were also used. The DM patients had significantly more caries, plaque, and gingivitis than did control patients. They had more TMD problems and lower co-operation ability than the healthy control persons. General sedation was frequently needed to carry through dental treatment. DM patients are at risk of caries, gingivitis and TMD problems, and need intensified prophylactic care. Behavior management problems are common.  相似文献   
3.
Objective. The Nordic Orofacial Test-Screening (NOT-S) was developed as a comprehensive method to assess orofacial function. Results from the screening protocol have been presented in 11 international publications to date. This study reviewed these publications in order to compile NOT-S screening data and create profiles of orofacial dysfunction that characterize various age groups and disorders. Materials and methods. NOT-S results of nine reports meeting the inclusion criteria were reviewed. Seven of these studies not only provided data on the mean and range of total NOT-S scores, but also on the most common domains of orofacial dysfunction (highest rate of individuals with dysfunction scores), allowing the construction of orofacial dysfunction profiles based on the prevalence of dysfunction in each domain of NOT-S. Results. The compiled data comprised 669 individuals, which included healthy control subjects (n = 333) and various patient groups (n = 336). All studies reported differences between individuals with diagnosed disorders and healthy control subjects. The NOT-S data could measure treatment effects and provided dysfunction profiles characterizing the patterns of orofacial dysfunction in various diagnoses. Conclusions. This review corroborates previous results that the NOT-S differentiates well between patients and healthy controls and can also show changes in individuals after treatment. NOT-S could be used as a standard instrument to assess orofacial dysfunction, evaluate the outcomes of oral habilitation and rehabilitation and improve comparability in clinical practice and research.  相似文献   
4.
5.
Dosimetry is important in the evaluation of new radiopharmaceuticals and in radionuclide therapy treatment planning. The base is an accurate in vivo measurement of the spatial and temporal distribution of the administered radioactivity. This can be made by planar whole-body activity quantification using the conjugate-view method where a geometrical-mean image is corrected for attenuation by a measured transmission image. We present a new method to measure whole-body transmission images using the X-ray unit on a single photon emission computed tomography/computed tomography (SPECT/CT) scintillation system. METHOD: Two general problems are associated with this method: (1) the divergence of the X-ray beam and (2) the scaling of the resulting image. We have applied linear transformations and scale by a system-generated factor to obtain images corresponding to a radiological depth at 70 keV. We validated the method by measurements of the radiological depth for different types of phantoms, and in terms of activity quantification accuracy when applying the method for attenuation correction. RESULTS: An accuracy of within +/-4% was found for both the radiological depth measurements and for the activity-quantification measurements. CONCLUSIONS: The advantage with the proposed method is that it is fast (2 minutes for a 2-minute scan), it has good spatial resolution and signal-to-noise ratio, and it is easy to carry out for the patient.  相似文献   
6.
A new method for absorbed-dose assessment in radionuclide therapy is presented in this paper. The method is based on activity quantification by the conjugate-view methodology, applied to serial whole-body, anterior-posterior, scintillation-camera scans. The quantification method is an extension of previous studies, and includes separate corrections for attenuation, scatter, and overlapping organs. Further development has now been undertaken to take into account the capabilities of new dual-head camera systems with a built-in X-ray tube for anatomical imaging. Furthermore, the modeling of time-activity data is included, and dosimetric calculations based on the formalism by the Medical Internal Radiation Dose (MIRD) committee. To streamline absorbed-dose assessments for a large number of patient studies, the programs for quantification, image registration, and absorbed-dose calculations have been embedded in an envelop program termed LundADose, where calculations, to a great extent, are performed automatically. Evaluation of the whole-body activity quantification is performed for patients undergoing radioimmunotherapy by monoclonal antibodies labeled with (111)In or (90)Y.  相似文献   
7.
Swedish patients with the oculo-auriculo-vertebral (OAV) spectrum participated in a prospective multidisciplinary investigation. The aims of the study were to describe their systemic and functional defects, especially autism spectrum disorders, and to search for possible etiologic risk factors. Available medical records were studied and the mothers answered a questionnaire on history of prenatal events. A clinical examination evaluating systemic findings, vision, hearing, speech, oral and swallowing function, and neuropsychiatric function, especially autism, was made. Eighteen patients, (11 males, 7 females) aged 8 months to 17 years with OAV were studied. Most frequent systemic malformations included, ear abnormalities (100%), ocular malformations (72%), vertebral deformities (67%), cerebral anomalies (50%), and congenital heart defects (33%). Functional defects consisted of hearing impairment (83%), visual impairment (28%), both visual and hearing impairment (28%), difficulties in feeding/eating (50%), speech (53%), mental retardation (39%), and severe autistic symptoms (11%). Three children were born following assisted fertilization (two intracytoplasmatic sperm injection, one in vitro fertilization), two mothers reported early bleedings, and six (33%) mothers had smoked during pregnancy.  相似文献   
8.
Abnormal processing of β-amyloid precursor protein (APP) and precipitation of amyloidogenic βA4 peptide have been implicated in the pathogenesis of Alzheimer’s disease (AD). In an attempt to generate an in vivo model of APP-associated pathology, we have introduced recombinant retroviral vectors harboring normal and mutant cDNAs for human neuron-specific APP 695 into fetal rat brain transplants. A minor population of recombinant neural cells with expression of APP was identified immunohistochemically in the grafts. The expression was maintained during an observation period of 9 months. Neurons with strong immunoreactivity for human APP exhibited markedly swollen perikarya and showed signs of cell degeneration. At 6 months post-transplantation, recombinant grafts developed APP-positive neuropil deposits with morphological features of neuritic plaques, but without βA4 peptide immunoreactivity. No difference was observed between wild-type APP and the mutant APP construct derived from a family with autosomal dominant AD. These observations indicate that long-term neuronal overexpression of human APP has the potential to generate APP plaques in the rodent brain. Received: 22 January 1996 / Accepted: 5 February 1996  相似文献   
9.
In SPECT imaging of pure beta emitters, such as (90)Y, the acquired spectrum is very complex, which increases the demands on the imaging protocol and the reconstruction. In this work, we have evaluated the quantitative accuracy of bremsstrahlung SPECT with focus on the reconstruction algorithm including model-based attenuation, scatter and collimator-detector response (CDR) compensations. The scatter and CDR compensation methods require pre-calculated point-spread functions, which were generated with the SIMIND MC program. The SIMIND program is dedicated for simulation of scintillation camera imaging and only handles photons. The aim of this work was therefore twofold. The first aim was to implement simulation of bremsstrahlung imaging into the SIMIND code and to validate simulations against experimental measurements. The second was to investigate the quality of bremsstrahlung SPECT imaging and to evaluate the possibility of quantifying the activity in differently shaped sources. In addition, a feasibility test was performed on a patient that underwent treatment with (90)Y-Ibritumomab tiuxetan (Zevalin). The MCNPX MC program was used to generate bremsstrahlung photon spectra which were used as source input in the SIMIND program. The obtained bremsstrahlung spectra were separately validated by experimental measurement using a HPGe detector. Validation of the SIMIND generated images was done by a comparison to gamma camera measurements of a syringe containing (90)Y. Results showed a slight deviation between simulations and measurements in image regions outside the source, but the agreement was sufficient for the purpose of generating scatter and CDR kernels. For the bremsstrahlung SPECT experiment, the RSD torso phantom with (90)Y in the liver insert was measured with and without background activities. Projection data were obtained using a GE VH/Hawkeye system. Image reconstruction was performed by using the OSEM algorithm with and without different combinations of model-based attenuation, scatter and CDR compensations. The reconstructed images were then evaluated in terms of the accuracy of the total activity estimate in the liver insert. It was found that the activity in a large source such as the liver was estimated with a bias of around -70%, when no compensations were included in the reconstruction, whereas when compensations were included the bias obtained was between -10 and 16%. It is concluded that although the (90)Y bremsstrahlung spectrum is continuous with no pronounced peak and the count rate is low, it is possible to achieve reasonably accurate activity estimates from bremsstrahlung SPECT images if proper compensations are applied in the reconstruction. This conclusion was also confirmed by the patient study.  相似文献   
10.
In this paper, we extend the high order finite-difference method with subcell resolution (SR) in [34] for two-species stiff one-reaction models to multispecies and multireaction inviscid chemical reactive flows, which are significantly more difficult because of the multiple scales generated by different reactions. For reaction problems, when the reaction time scale is very small, the reaction zone scale is also small and the governing equations become very stiff. Wrong propagation speed of discontinuity may occur due to the underresolved numerical solution in both space and time. The present SR method for reactive Euler system is a fractional step method. In the convection step, any high order shock-capturing method can be used. In the reaction step, an ODE solver is applied but with certain computed flow variables in the shock region modified by the Harten subcell resolution idea. Several numerical examples of multispecies and multireaction reactive flows are performed in both one and two dimensions. Studies demonstrate that the SR method can capture the correct propagation speed of discontinuities in very coarse meshes.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号