首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   43篇
  免费   0篇
基础医学   1篇
临床医学   16篇
内科学   5篇
神经病学   1篇
特种医学   5篇
外科学   10篇
预防医学   3篇
药学   1篇
肿瘤学   1篇
  2023年   1篇
  2021年   1篇
  2019年   2篇
  2018年   1篇
  2014年   1篇
  2012年   4篇
  2011年   3篇
  2010年   1篇
  2009年   6篇
  2008年   5篇
  2007年   1篇
  2006年   4篇
  2005年   1篇
  2004年   3篇
  2003年   1篇
  1998年   1篇
  1994年   1篇
  1993年   1篇
  1992年   1篇
  1981年   1篇
  1980年   1篇
  1978年   1篇
  1967年   1篇
排序方式: 共有43条查询结果,搜索用时 15 毫秒
1.
2.
This paper describes a study of perceptions of nursing by nursing students, qualified nurses (United Kingdom and Spain), patients and non-nursing students. A survey method was used with a longitudinal panel element incorporating a 35-item version of the Nursing Dimensions Inventory translated into Spanish. Data were analysed using principal component analysis, congruence analysis, Mokken scaling, correlation, ANOVA, t-test and Cronbach's alpha. Patients may perceive nursing differently from nursing students, nurses (in the UK and Spain) and non-nurses. These findings are discussed in the context of nurse education and patient care.  相似文献   
3.
4.
OBJECTIVE: Intra-operative cell salvage is increasingly used, especially in longer cases with continuing blood loss. However it is unknown if the quality of processed blood is affected when larger quantities of blood are processed. We hypothesized that the quality of the washed blood decreases after multiple runs. METHODS: Intra-operative cell salvage was performed in 42 consecutive patients undergoing cardiac surgery. When 1250 ml of blood was collected in the blood collection reservoir, this was processed and returned to the patient. In 21 patients more than 2500 ml of blood was collected during the whole procedure, thus allowing at least two subsequent runs with the auto-transfusion device. Blood samples were drawn from the blood collection reservoir of the cell saver device before, and from the processed blood after each run. RESULTS: After the first run interleukin-6 concentrations were reduced with 85% (from 21+/-35 microg/l to 3.1+/-4.4 microg/l), whereas after the second run 72% was removed (63+/-69 microg/l to 17.6+/-25.3 microg/l). Leukocyte counts almost doubled after both processing runs (from 2.6+/-1.5 x 10(9)/l to 5+/-3.6 x 10(9)/l) and from 3.9+/-2.2 x 10(9)/l to 7.7+/-5.9 x 10(9)/l), hemoglobin concentration (14.8+/-1.6 mmol/l vs 15.0+/-1.1 mmol/l), free hemoglobin (2.3+/-1.6g/l vs 2.1+/-1.4 g/l) and platelet counts (18+/-9 x 10(9)/l vs 28+/-23 x 10(9)/l) were not different between the two runs. CONCLUSIONS: Our results suggest, based on interleukin-6 and free hemoglobin washout that the quality of the processed blood remains constant with multiple runs of the cell saver device.  相似文献   
5.
BACKGROUND: Diabetes mellitus (DM) is diagnosed and monitored worldwide by blood glucose (BG) and glycohemoglobin A(1c) (HbA(1c)) testing, respectively. Methods for quality assessment of clinician interpretations of changes in these laboratory results have been developed. This study uses survey responses from general practitioners (GPs) in different countries to investigate possible differences in interpretation of results, as well as the feasibility of performing international postanalytical external quality assessment surveys (P-EQAS). METHODS: GPs recruited from 7 countries received questionnaires requesting interpretation of changes in a potentially diagnostic capillary BG result and an HbA(1c) value obtained during monitoring of a patient with type 2 DM. GPs were asked to estimate clinically significant differences between 2 consecutive laboratory results [critical difference (CD)/reference change value] for both BG and HbA(1c). The CDs reported by GPs were used to calculate the analytical variation (CV(a)), which was taken as the quality specification for analytical imprecision. Participants received national benchmarking feedback reports after the survey. RESULTS: The study included responses from 2538 GPs. CDs in BG results showed the same pattern and were comparable among countries. Calculated median CV(a) values would be possible to attain at 80% confidence but not at the conventional 95% confidence. For HbA(1c), the same pattern was shown across countries, but with lower changes considered true when HbA(1c) increased than when it decreased. Despite the consistent pattern, variations among GPs were considerable in all countries. CONCLUSIONS: Assessments of CDs for BG and HbA(1c) were similar internationally, and quality specifications for these analytes based on clinicians' opinions are therefore interchangeable among countries. International P-EQAS may contribute to a more rational use of laboratory services and clinical guidelines.  相似文献   
6.
7.
8.
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号