首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   66篇
  免费   0篇
儿科学   1篇
妇产科学   1篇
基础医学   3篇
口腔科学   3篇
临床医学   31篇
内科学   17篇
神经病学   1篇
外科学   3篇
预防医学   3篇
眼科学   1篇
药学   2篇
  2021年   1篇
  2014年   3篇
  2013年   4篇
  2012年   1篇
  2010年   3篇
  2009年   5篇
  2007年   1篇
  2006年   3篇
  2003年   4篇
  2001年   1篇
  2000年   1篇
  1999年   4篇
  1998年   9篇
  1997年   5篇
  1996年   4篇
  1995年   1篇
  1994年   1篇
  1993年   1篇
  1992年   2篇
  1990年   1篇
  1983年   1篇
  1980年   1篇
  1979年   1篇
  1972年   2篇
  1956年   1篇
  1955年   1篇
  1954年   2篇
  1948年   2篇
排序方式: 共有66条查询结果,搜索用时 453 毫秒
1.
2.
3.
4.
Catheter Ablation of Ventricular Tachycardia.   Introduction: Ventricular tachycardia (VT) late after myocardial infarction is an important contributor to morbidity and mortality. This prospective multicenter study assessed the efficacy and safety of electroanatomical mapping in combination with open-saline irrigated ablation technology for ablation of chronic recurrent mappable and unmappable VT in remote myocardial infarction.
Methods and Results: In 8 European institutions, 63 patients (89% males) were enrolled in the study. All patients had remote myocardial infarction and presented with a median number of 17 (range 1–380) VTs in the preceding 6 months. Incessant VT was present in 14 patients (22%). Left ventricular ejection fraction measured 30 ± 13%. A mean of 3 VTs were targeted per patient and 22% of all patients had only unmappable VT. The mean follow-up period was 12 ± 3 months. A total of 164 VTs were targeted during catheter ablation. Ablation was acutely successful in 51 patients (81%). One patient (1.5%) experienced a major complication with degeneration of VT into ventricular fibrillation necessitating cardiopulmonary resuscitation maneuvers. However, no death occurred acutely or within the first 30 days after catheter ablation. During the follow-up, 19 of the initially successful ablated patients (37%) and 31 of all ablated patients (49%) developed some type of VT recurrence.
Conclusions: The results of this multicenter study demonstrate the high acute success rate and a low complication rate of irrigated tip catheter ablation of all clinical relevant VTs in remote myocardial infarction. However, during the follow-up a relevant number of recurrences occurred. (J Cardiovasc Electrophysiol, Vol. 21, pp. 47–53, January 2010)  相似文献   
5.
6.
It has been hypothesized that during radiation treatment a reoxygenation of hypoxic tumor tissue takes place. To test this hypothesis, we have investigated whether reoxygenation in lymph node metastases could be determined by invasive PO (2) measurements. Through a hypodermic needle inserted transcutaneously into tumor-positive lymph nodes, polarographic oxygen determinations were made in 18 patients with advanced squamous cell carcinomas of the oropharynx and hypopharynx. These measurements were performed before therapy and a week after the onset of radiotherapy or radiochemotherapy, respectively. Low PO (2) values before treatment (mean value of the patient's median was 12.6 mm Hg PO (2)) and a mean hypoxic fraction (PO (2) < 5 mm Hg) of 39.6% indicated manifest tumor hypoxia. After 1 week of treatment, a significant increase in the median PO (2) (mean value of shift: 7.3 mm Hg) and a reduction in the hypoxic fraction (mean value of shift: 13.4% PO (2) < 5 mm Hg, P < 0.03) were observed after both radiotherapy and radiochemotherapy. Thus invasive PO (2) histography fulfills the requirements for a method to confirm tumor hypoxia in head and neck tumors. The results obtained indicate that reoxygenation occurs during the initial phases of radiotherapy and radiochemotherapy, and they will form the basis for future comparative investigations on the possible influence of hypoxic parameters on tumor responsiveness toward radiation and radiochemotherapy.  相似文献   
7.
Early or localized forms of arrhythmogenic right ventricular dysplasia (ARVD) have been proposed as the arrhythmogenic substrate of repetitive monomorphic ventricular tachycardia (RMVT) originating in the right ventricular outflow tract in patients without any underlying cardiac abnormality on clinical examination and echocardiography. To further examine this hypothesis, magnetic resonance imaging (MRI) and signal-averaged electrocardiography (SAECG) were performed on 23 patients with RMVT and normal 12-lead standard ECG of conducted sinus beats. MRI was performed using ECG-gated turbo spin-echo images of the heart in order to detect signs of early or localized forms of ARVD, such as localized wall thickness reductions, signal intensity increase indicating adipose tissue infiltrates, and regional bulgings or aneurysms. MRI was normal in 22 (96%) of 23 study patients. In the remaining patient (4%), MRI demonstrated signal intensity increase in the intraventricular septum but not in the right ventricular outflow tract. Time-domain analysis of the SAECG was normal in 21 (91 %) of 23 patients and revealed ventricular late potentials in 2 study patients (9%). Frequency-domain analysis of the SAECG was normal in 22 (96%) of 23 patients and revealed ventricular late potentials in one study patient (4 %). We conclude that normal MRI findings of the heart and absence of ventricular late potentials in the SAECC in most patients with RMVT and otherwise normal ECG do not support the hypothesis that early or localized forms of ARVD create the arrhythmogenic substrate in the majority of these patients.  相似文献   
8.
This study investigates the influence of various lead geometry on intracardial signals like the monophasic action potential (MAP) to optimize the geometry of implantable MAP leads. The experimental results were compared with a field theoretical approach to the origin of MAP from the transmembrane potential (TAP). During the experiments several lead geometries (tip surface: 1.3 to 12 mm2; tip-ring distance: 0.8 mm to 25 cm; ring surface: 1.8mm2 to 40 mm2) were investigated in endo- and epicardial positions in 12 dogs (17±9 kg). The electrodes were fixed passively (tines) or actively (screws). MAP was recorded during several interventions and correlated with MAP measured using an Ag-AgCl MAP catheter. The experimental results showed that small tips provided high MAP amplitudes with less pressure. No difference was observed using active and passive fixations. A tip-ring distance smaller than 5 mm with a ring surface smaller than the tip (<5 mm2) avoided artifacts in the repolarization course. For the theoretical approach the quasistatic, anisotropic bidomain model was calculated in smalt unity volumes Vi where the TAP φm was constant and represented by the current density J. Two solutions for electrode positions at and outside the heart were achieved. By superposition of each solution φei the summed potential at the electrode position was calculated. The theoretical findings show in good correlation with the experimental results that a larger distance than 10 mm leads to distortions in repolarization course by signals proportional to φout.  相似文献   
9.
COMMMENTS     
Germ cell tumours (CT) are no true carcinomas; therefore the term testicular intraepithelial neoplasia (IN) is probably more appropriate than “CIS”. The diagnostic accuracy of a single‐site biopsy is an open question. We experienced 9 false‐negative biopsies among 1859 cases. Thus, the proportion of a failed diagnosis is 0.5%. The main reason for diagnostic failure is the non‐random distribution of TIN within the testicle. Currently we are investigating whether a two‐site biopsy is more accurate than a single biopsy. In the ongoing trial, the over‐all prevalence of TIN is around 5.3%, so far. In one quarter of the positive cases the lesion was found in only one of the two specimens. Thus, a double biopsy appears to be more favourable than the traditional single biopsy. Surgical complications amount to 2.5% in that double biopsy study. Only one surgical re‐intervention was required among 983 patients. Serial imaging studies with scrotal sonography and magnetic resonance imaging (MRI) disclosed a transient intratesticular haematoma/oedema postoperatively. So, testicular biopsy, even when performed at two sites is in fact a low‐complication procedure. Low dose radiotherapy to the testis is the treatment of choice for TIN. However, more than one quarter of patients require testosterone supplementation secondary to androgen‐deficiency. Two dose‐reduction studies (Denmark and Germany) had to be terminated prematurely because unexpected relapse of TIN was encountered at 14 Gy and 16 Gy. Possibly, hyperfragmentation schedules can overcome the antagonism of androgenic compromise and oncological safety. In a nation‐wide survey, it was shown that contralateral biopsies were routinely performed in 66% of the urological departments in Germany. Another 19% offered the biopsy to particular “risk‐cases”; only 15% never did a biopsy. Among those refusing biopsies, there was a higher proportion of small hospitals and a significantly lower annual case‐number of GCT, when compared to those doing the biopsy. Thus, the contralateral biopsy is a well‐established procedure among German urologists; those with a high caseload of GCT particularly appreciate it.  相似文献   
10.
Even with the use of biphasic shocks, up to 5% of patients need an additional subcutaneous lead to obtain a defibrillation safety margin of at least 10 J. The number of patients requiring additional subcutaneous leads may even increase, because recent generation devices have a < 34 J maximum output in order to decrease their size. In 20 consecutive patients, a single element subcutaneous array lead was implanted in addition to a transvenous lead system consisting of a right ventricular (RV) and a vena cava superior lead using a single infraclavicular incision. The RV lead acted as the cathode; the subcutaneous lead and the lead in the subclavian vein acted as the anode. The biphasic defibrillation threshold was determined using a binary search protocol. Patients were randomized as to whether to start them with the transvenous lead configuration or the combination of the transvenous lead and the subcutaneous lead. In addition, a simplified assessment of the defibrillation field was performed by determining the interelectrode area for the transvenous lead only and the transvenous lead in combination with the subcutaneous lead from a biplane chest X ray. The intraoperative defibrillation threshold was reconfirmed after 1 week, after 3 months, and after 12 months. The mean defibrillation threshold with the additional subcutaneous lead was significantly (P = 0.0001) lower (5.7 ± 2.9 J) than for the transvenous lead system (9.5 ± 4.6 J). With the subcutaneous lead, the impedance of the high voltage circuit decreased from 48.9 ± 7.4 Ω to 39.2 ± 5.0 Ω. In the frontal plane, the interelectrode area increased by 11.3%± 5.5% (P < 0.0001) and in the lateral plane by 29.5%± 12.4% (P < 0.0001). The defibrillation threshold did not increase during follow-up. Complications with the subcutaneous electrode were not observed during a follow-up of 15.8 ± 2 months. The single finger array lead is useful in order to lower the defibrillation threshold and can be used in order to lower the defibrillation threshold.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号