STUDY OBJECTIVE: To evaluate the safety and efficacy of small-bore, silastic drains for patients undergoing general thoracic surgery. PATIENTS AND METHODS: Twenty-five patients who received soft, small-bore, silastic drains were compared with 17 patients who received semi-rigid double lumen (DL) tubes retrospectively. RESULTS: The pain score was significantly lower in patients who received the silastic tubes in video-assisted thoracoscopic surgery (VATS) cases on postoperative days 5 and 6 , after continuous epidural analgesia had finished (P=0.018). No specific morbidity was seen in the patients who received silastic tubes. CONCLUSION: We considered that soft, small-bore silastic drains were just as effective as traditional DL tubes, but caused less pain especially in VATS cases. 相似文献
Abstract: Prevention of hyperacute rejection is a difficult and unsolved problem in xenotransplantation. Natural antibodies and complement activation have been known to play an important role in the xenotransplantation between discordant species pairs. In the present study, total blood exchange (TBE) was performed with pyridox-alated-hemoglobin-polyoxyethylene conjugate (PHP) solution (Ajinomoto Co., Inc., Kawasaki, Japan) before cardiac xenotransplantation in order to remove the immunoglobulins and prolong xenograft survival time. Guinea pigs and rats were used as the discordant species combination for donor and recipient. Two groups were established: Group 1, untreated control (n = 8) and Group 2, TBT with PHP solution (n = 8). The exchange blood transfusion was carried out at the rate of 15–20 ml/h utilizing PHP solution using a blood pump. After the blood exchange was processed, hematocrit (Ht) levels dropped to 4 or 5%, and a cardiac xenotransplantation was performed within 24 h. The levels of serum IgA, IgM, and IgG were decreased to less than 25, 25, and 10% of the base line, respectively, after blood exchange. A mean xenograft survival time in Group 2 was prolonged to 472 ± 74 min and to 10.4 ± 1.8 min in Group 1 (p < 0.01). A titer of the anti-guinea pig lymphocytotoxic antibody in rat serum was decreased to almost nil. The data from this study suggest that total blood exchange with PHP solution may be useful in preoperative removal of xenograft antibodies in xenotransplantation. 相似文献
Background: Some anesthetics relax airway smooth muscle in part by inhibiting acetylcholine-induced increases in Ca2+ sensitivity, an effect associated with inhibition of guanosine nucleotide exchange at the [alpha] subunit of the Gq/11 (G[alpha]q/11) heterotrimeric G protein. This study tested the hypothesis that these anesthetic effects are not unique to the muscarinic receptor but are a general property of the heptahelical receptors that increase Ca2+ sensitivity in airway smooth muscle.
Methods: Anesthetic effects on agonist-induced increases in Ca2+ sensitivity were measured in porcine airway smooth muscle strips permeabilized with S. aureus [alpha]-toxin. Anesthetic effects on basal (without agonist stimulation) and agonist-promoted G[alpha]q/11 guanosine nucleotide exchange were determined in crude membranes prepared from porcine airway smooth muscle. The nonhydrolyzable, radioactive form of guanosine 5'-triphosphate was used as the reporter for nucleotide exchange at G[alpha]q/11.
Results: Acetylcholine, endothelin-1, and histamine caused a concentration-dependent increase in Ca2+ sensitivity. Halothane (0.67 +/- 0.07 mm) and hexanol (10 mm) significantly inhibited the increase in Ca2+ sensitivity induced by each agonist. Each agonist also caused a time- and concentration-dependent increase in G[alpha]q/11 nucleotide exchange. Neither anesthetic had an effect on basal G[alpha]q/11 nucleotide exchange, whereas halothane and hexanol significantly inhibited the increase in G[alpha]q/11 nucleotide exchange promoted by each agonist. 相似文献
OBJECTIVES: Graft failure has been reported when the arterial conduit, such as the internal thoracic artery (ITA) or the right gastroepiploic artery (GEA), is grafted to a lower grade coronary artery stenosis. The shear stress as a significant factor affecting graft patency was compared between the arterial conduit and the saphenous vein graft (SVG) after surgery. METHODS: In 101 patients, 40 ITAs, 27 GEAs and 34 SVGs were examined using a Doppler-tipped guide wire during postoperative angiography. The graft flow volume and shear stress were calculated from velocity and diameter data. The study grafts were classified according to the grade of native coronary artery stenosis: group L had more than 50 up to 75% stenosis, and group H had more than 75% stenosis. Group H consisted of 25 ITAs, 17 GEAs and 21 SVGs, while group L consisted of 15 ITAs, 10 GEAs and 13 SVGs. RESULTS: In group H, graft flow volume did not significantly differ among the ITA (34+/-11 ml/min), GEA (36+/-16 ml/min) and SVG (41+/-15 ml/min), and graft shear stress significantly (ITA vs. GEA P<0.0001; GEA vs. SVG P<0.01) differed among the ITA (16.0+/-4.8dyn/cm(2)), GEA (9.1+/-3.2dyn/cm(2)) and SVG (4.8+/-1.6dyn/cm(2)). In group L, flow volume was lower (P<0.001) in the ITA (18+/-6 ml/min) and GEA (13+/-8 ml/min) than in the SVG (35+/-16 ml/min), and shear stress was significantly (P<0.001) greater in the ITA (13.7+/-4.9dyn/cm(2)) than the GEA (5.6+/-2.0dyn/cm(2)) or SVG (4.6+/-2.0dyn/cm(2)). CONCLUSIONS: These data suggest that shear stress of the ITA is superior and maintained despite the flow volume being reduced by flow competition. Lower shear stress of the GEA for intermediate stenosis may be associated with the development of conduit failure. 相似文献
Abstract: Suitable evaluation systems are critical for ranking various biomaterials in order to develop a method to design and synthesize nonthrombogenic biomaterials. We have recently developed an in vitro test system to evaluate platelet/biomaterial interactions in whole blood. The system consists of a parallel plate flow cell and epifluorescent video microscopy (EVM). A glass coverslip coated with a polymer was incorporated into the flow cell, and blood was perfused using a syringe pump via a polymer–coated PVC tubing connected to the flow cell. Whole human blood was anticoagulated with heparin (2 U/ml), and the platelets were labeled with the fluorescent dye mepacrine (5 μM). This system permitted real–time and dynamic observations of platelet/biomaterial interactions in whole blood under a defined flow condition. In order to evaluate the feasibility of this system, two different segmented polyether–polyurethanes (SPEUs), PU–PTMG(650) and PU–PTMG(2000), were chosen as test polymers. Surface characteristics verified with electron spectroscopy for chemical analysis (ESCA) and contact angle measurements showed similar results in both SPEUs. Blood was perfused at a wall shear rate of 200 s–1 for 20 min. Excitation light was applied for 2 s at 1 min intervals. The real–time image was then analyzed at each time point for the percentage of surface area of platelet coverage. Plasma β–thromboglobulin (β–TG) levels were also measured before and after each run. PU–PTMG(650) showed a significantly higher number of adhered platelets than PU–PTMG(2000) at each time point. β–TG levels of PU–PTMG(650) were also higher than those of PU–PTMG(2000), which is comparable to the results of EVM. Thus, this EVM system has been proven to be an excellent and highly sensitive in vitro analytical method for evaluating platelet/biomaterial interactions. 相似文献
Prostaglandin E1 (PGE1) was used in renal transplant recipients with living related donors. The drug was given intravenously from day 1 to day 7 after transplantation at a dose of 40 µg/kg twice a day. A total of 45 patients were studied divided into two groups: 25 patients were treated with PGE1 (group B) and the remaining 20 patients did not receive the drug (group A). In group B, 24-h creatinine clearance (Ccr) was 66 ± 12.8 ml/min compared with 40.3 ± 13.4 ml/min in group A on the fifth postoperative day (P < 0.05). Urinary levels of N-acetyl-β-d -glucosaminidase (NAG) and serum levels of platelet factor 4 (PF4) in group B were significantly lower than in group A. On the fourth postoperative day, the urinary excretion of thromboxan B2 (TxB2) in group A was higher than in group B, but not significantly (5.1 ± 3.0 ng/day and 2.8 ± 1.1 ng/day, respectively). Acute rejection occurred in four patients in group B and in 10 patients (40%) in group A. The percentage of Leu2a-positive lymphocytes in group B was higher than in group A. We conclude that postoperative administration of PGE1 improves graft function in kidneys from living related donors. 相似文献
Continuous recirculating peritoneal dialysis (CRPD) was introduced to enhance solute removal efficiency in conventional peritoneal dialysis (PD) therapies such as continuous ambulatory peritoneal dialysis (CAPD). In CRPD, a portion of the dwell dialysate in the patient's peritoneal cavity is drained through a double-lumen catheter and purified by an extracorporeal dialyzer. In this study, solute removal characteristics and safety of CRPD are examined in ex vivo and clinical studies. Recirculation dialysis experiments using nine dogs (13.6 +/- 2.5 kg of body weight) were carried out for 240 min in the ex vivo study, whereas another seven dogs (12.1 +/- 2.8 kg) received conventional peritoneal dialysis (CPD) (120 min dwelling x 2) and six additional dogs (11.9 +/- 2.7 kg) received a Tidal PD (20 min dwelling x 12; 50% of tidal volume ratio) as controls. The ex vivo study revealed that CRPD has a higher efficiency for solute removal than CPD and is equivalent to Tidal PD. In the BUN reduction rate, the 19.4 +/- 5.5% in 240 min CRPD (n = 9) was significantly higher (p < 0.05) than the 3.5 +/- 3.6% in 240 min CPD (n = 7) and equivalent to the 17.3 +/- 4.7% in 240 min Tidal PD (n = 6). Continuous recirculating peritoneal dialysis maintained a low UN level in the peritoneal cavity due to dialysis with an extracorporeal dialyzer. This tendency was also seen in creatinine removal. In the clinical study, CRPD (n = 10) and CPD (n = 5) treatments were used in three renal failure patients. Higher solute removal efficiency was shown in CRPD than in CPD treatments, and the urea peritoneal clearance was 14.1 +/- 4.4 ml/min in CRPD (n = 10), significantly higher (p < 0.05) than the 7.3 +/- 2.1 ml/min in CPD (n = 5). No fibrin formation occurred during CRPD treatments. 相似文献
A broad range of chronic conditions, including heart failure (HF), have been associated with vitamin D deficiency. Existing clinical trials involving vitamin D supplementation in chronic HF patients have been inconclusive. We sought to evaluate the outcomes of patients with vitamin D supplementation, compared with a matched cohort using real-world big data of HF hospitalization. This study was based on the Diagnosis Procedure Combination database in the Japanese Registry of All Cardiac and Vascular Datasets (JROAD-DPC). After exclusion criteria, we identified 93,692 patients who were first hospitalized with HF between April 2012 and March 2017 (mean age was 79 ± 12 years, and 52.2% were male). Propensity score (PS) was estimated with logistic regression model, with vitamin D supplementation as the dependent variable and clinically relevant covariates. On PS-matched analysis with 10,974 patients, patients with vitamin D supplementation had lower total in-hospital mortality (6.5 vs. 9.4%, odds ratio: 0.67, p < 0.001) and in-hospital mortality within 7 days and 30 days (0.9 vs. 2.5%, OR, 0.34, and 3.8 vs. 6.5%, OR: 0.56, both p < 0.001). In the sub-group analysis, mortalities in patients with age < 75, diabetes, dyslipidemia, atrial arrhythmia, cancer, renin-angiotensin system blocker, and β-blocker were not affected by vitamin D supplementation. Patients with vitamin D supplementation had a lower in-hospital mortality for HF than patients without vitamin D supplementation in the propensity matched cohort. The identification of specific clinical characteristics in patients benefitting from vitamin D may be useful for determining targets of future randomized control trials. 相似文献
BACKGROUND: In organ transplantation, the grafts must be carefully monitored, but it is often difficult to make a quick and accurate diagnosis of unusual changes. Extensive research has failed to identify a useful marker for rejection. We investigated the clinical utility of sialyl Lewis(X) (CD15s) monitoring in 17 renal transplant patients with acute rejection. METHODS: The expression of CD15s on peripheral lymphocytes was examined using flow cytometry in renal transplant recipients with rejection (n=17), without rejection (n=23), recipients infected with cytomegalovirus (n=7), recipients with other diseases (n=7), and healthy volunteers (n=18). CD15s expression was compared with histological findings, and was also examined before and after steroid pulse therapy to investigate the effects of steroids on CD15s antigen expression on the surface of the peripheral lymphocytes. RESULTS: CD15s was strongly expressed in all patients with rejection, but was not expressed in any of the patients without rejection or in any healthy volunteers. Histologically, cell infiltration into the rejected graft was moderate or severe in all patients with strong expression of CD15s. In contrast, no or only mild infiltration was observed in patients with weak expression of CD15s. In addition, 14 of 17 patients (14/17, 82%) with strong CD15s expression improved upon administration of steroid pulse therapy, although there was no benefit from steroids in any of the patients with weak expression of CD15s. CONCLUSIONS: The CD15s antigen is expressed strongly on the peripheral lymphocytes at the time of rejection. It is interesting that the efficacy of steroid therapy in the patients with elevated creatinine could be predicted by CD15s expression on the peripheral lymphocytes before graft biopsy. There have been only few reports showing the relationship between CD markers and the efficacy of the treatment in patients with elevated creatinine. We report that the detection of CD15s on the peripheral lymphocytes by flow cytometry was an easy, helpful, and noninvasive means for the diagnosis and treatment of patients with elevated creatinine after renal transplantation. 相似文献