全文获取类型
收费全文 | 292篇 |
免费 | 10篇 |
专业分类
耳鼻咽喉 | 4篇 |
儿科学 | 1篇 |
妇产科学 | 5篇 |
基础医学 | 62篇 |
口腔科学 | 6篇 |
临床医学 | 13篇 |
内科学 | 50篇 |
皮肤病学 | 1篇 |
神经病学 | 8篇 |
特种医学 | 18篇 |
外科学 | 21篇 |
综合类 | 27篇 |
一般理论 | 2篇 |
预防医学 | 26篇 |
药学 | 15篇 |
中国医学 | 2篇 |
肿瘤学 | 41篇 |
出版年
2022年 | 11篇 |
2021年 | 24篇 |
2020年 | 10篇 |
2019年 | 10篇 |
2018年 | 11篇 |
2017年 | 5篇 |
2016年 | 3篇 |
2015年 | 5篇 |
2014年 | 16篇 |
2013年 | 13篇 |
2012年 | 36篇 |
2011年 | 25篇 |
2010年 | 10篇 |
2009年 | 9篇 |
2008年 | 13篇 |
2007年 | 19篇 |
2006年 | 16篇 |
2005年 | 15篇 |
2004年 | 14篇 |
2003年 | 13篇 |
2002年 | 7篇 |
2001年 | 4篇 |
2000年 | 2篇 |
1999年 | 4篇 |
1992年 | 1篇 |
1991年 | 2篇 |
1989年 | 1篇 |
1983年 | 1篇 |
1980年 | 1篇 |
1979年 | 1篇 |
排序方式: 共有302条查询结果,搜索用时 15 毫秒
1.
Antimicrobial susceptibilities and plasmid contents of Neisseria gonorrhoeae isolates from commercial sex workers in Dhaka, Bangladesh: emergence of high-level resistance to ciprofloxacin 总被引:6,自引:0,他引:6 下载免费PDF全文
Bhuiyan BU Rahman M Miah MR Nahar S Islam N Ahmed M Rahman KM Albert MJ 《Journal of clinical microbiology》1999,37(4):1130-1136
Commercial sex workers (CSWs) serve as the most important reservoir of sexually transmitted diseases (STD), including gonorrhea. Periodic monitoring of the antimicrobial susceptibility profile of Neisseria gonorrhoeae in a high-risk population provides essential clues regarding the rapidly changing pattern of antimicrobial susceptibilities. A study concerning the prevalence of gonococcal infection among CSWs was conducted in Bangladesh. The isolates were examined with regards to their antimicrobial susceptibility to, and the MICs of, penicillin, tetracycline, ciprofloxacin, cefuroxime, ceftriaxone, and spectinomycin by disk diffusion and agar dilution methods. The total plasmid profile of the isolates was also analyzed. Of the 224 CSWs, 94 (42%) were culture positive for N. gonorrhoeae. There was a good correlation between the results of the disk diffusion and agar dilution methods. Some 66% of the isolates were resistant to penicillin, and 34% were moderately susceptible to penicillin. Among the resistant isolates, 23.4% were penicillinase-producing N. gonorrhoeae (PPNG). 60.6% of the isolates were resistant and 38.3% were moderately susceptible to tetracycline, 17.5% were tetracycline-resistant N. gonorrhoeae, 11.7% were resistant and 26.6% had reduced susceptibility to ciprofloxacin, 2.1% were resistant and 11.7% had reduced susceptibility to cefuroxime, and 1% were resistant to ceftriaxone. All PPNG isolates contained a 3.2-MDa African type of plasmid, and a 24.2-MDa conjugative plasmid was present in 34.1% of the isolates. Since quinolones such as ciprofloxacin are recommended as the first line of therapy for gonorrhea, the emergence of significant resistance to ciprofloxacin will limit the usefulness of this drug for treatment of gonorrhea in Bangladesh. 相似文献
2.
Andreo P Huq MS Westermark M Song H Tilikidis A DeWerd L Shortt K 《Physics in medicine and biology》2002,47(17):3033-3053
A new international Code of Practice for radiotherapy dosimetry co-sponsored by several international organizations has been published by the IAEA, TRS-398. It is based on standards of absorbed dose to water, whereas previous protocols (TRS-381 and TRS-277) were based on air kerma standards. To estimate the changes in beam calibration caused by the introduction of TRS-398, a detailed experimental comparison of the dose determination in reference conditions in high-energy photon and electron beams has been made using the different IAEA protocols. A summary of the formulation and reference conditions in the various Codes of Practice, as well as of their basic data, is presented first. Accurate measurements have been made in 25 photon and electron beams from 10 clinical accelerators using 12 different cylindrical and plane-parallel chambers, and dose ratios under different conditions of TRS-398 to the other protocols determined. A strict step-by-step checklist was followed by the two participating clinical institutions to ascertain that the resulting calculations agreed within tenths of a per cent. The maximum differences found between TRS-398 and the previous Codes of Practice TRS-277 (2nd edn) and TRS-381 are of the order of 1.5-2.0%. TRS-398 yields absorbed doses larger than the previous protocols, around 1.0% for photons (TRS-277) and for electrons (TRS-381 and TRS-277) when plane-parallel chambers are cross-calibrated. For the Markus chamber, results show a very large variation, although a fortuitous cancellation of the old stopping powers with the ND,w/NK ratios makes the overall discrepancy between TRS-398 and TRS-277 in this case smaller than for well-guarded plane-parallel chambers. Chambers of the Roos-type with a 60Co ND,w calibration yield the maximum discrepancy in absorbed dose, which varies between 1.0% and 1.5% for TRS-381 and between 1.5% and 2.0% for TRS-277. Photon beam calibrations using directly measured or calculated TPR20,10 from a percentage dose data at SSD = 100 cm were found to be indistinguishable. Considering that approximately 0.8% of the differences between TRS-398 and the NK-based protocols are caused by the change to the new type of standards, the remaining difference in absolute dose is due either to a close similarity in basic data or to a fortuitous cancellation of the discrepancies in data and type of chamber calibration. It is emphasized that the NK-ND,air and ND,w formalisms have very similar uncertainty when the same criteria are used for both procedures. Arguments are provided in support of the recommendation for a change in reference dosimetry based on standards of absorbed dose to water. 相似文献
3.
S. Peat P. Sweet Y. Miah M. Barklamb U. Larsen 《European journal of clinical pharmacology》1999,55(8):577-581
Objective: This study evaluated Repro-Dose morphine (RDM; Reliadol from Nycomed Pharma), a new once daily controlled-release morphine
formulation, against twice daily MST Continus (MST) at steady state in patients with chronic opioid responsive pain.
Methods: A randomized double-blind two-way crossover design was used to evaluate the efficacy and adverse effects of RDM once daily
or MST twice daily, at the same total daily doses, in patients with chronic stable pain (dose range 20–120 mg per day). During
the RDM limb of the study active drug was administered in the evening and placebo in the morning. Dextromoramide was provided
as escape analgesia throughout the study. Following a 5-day screening period, during which stability of oral opioid dose was
verified, patients underwent two 5-day treatment periods, (one MST, one RDM) in random sequence. Pain scores, escape analgesia
requirements and side-effects were compared using data from days 3, 4 and 5 of each treatment period. Any events or medication
changes occurring during the study period thought liable to influence analgesia were regarded as protocol violations. Overall
assessment and period preference was assessed by direct questioning. RDM treatment was regarded as successful if the amount
of escape medication required during the RDM period was equal to or less than that required during the MST period.
Results: Forty-seven patients were included in the study, of whom 40 completed both periods [the intention to treat (ITT) population],
31 in strict accordance with the protocol [the per protocol (PP) population]. Results were similar for both populations. There
was no significant difference in pain scores or incidence of adverse events occurring during the MST and RDM periods. For
the ITT population, requirements for escape medication during the RDM period were less than, equal to or greater than those
recorded during the MST period for 14, 15, and 11 patients, respectively. Twenty-nine of 40 patients (72.5%) were therefore
RDM treatment successes (95% confidence interval 56.1–85.4%). The percentage of patients preferring RDM (45%) combined with
those with no preference (32.5%) was significantly higher than those preferring MST (22.5%; P = 0.0003).
Conclusions: Oral morphine administered as RDM once daily is at least as effective and well tolerated as MST twice daily, with over 70%
of patients in this double-blind crossover study reporting that RDM was equal or superior to MST.
Received: 6 April 1998 / Accepted in revised form: 23 January 1999 相似文献
4.
5.
6.
Md. Rezwan Miah Takeo Ohsaka 《Journal of electroanalytical chemistry (Lausanne, Switzerland)》2009,633(1):71-77
Oxygen reduction reaction (ORR) was investigated using polycrystalline gold (Au (poly)) electrode modified with chemisorbed iodine (I(ads)) submonolayer (sub I(ads)) in O2-saturated 0.1 M KOH solution. The sub I(ads) was tailored by potential-dependent partial reductive desorption of I(ads) from its full monolayer. The Au (1 1 1) facet of the Au (poly) electrode was considered to remain bared at the sub I(ads)/Au (poly) electrode. The interesting finding of the present study is that (unlike the bare Au (poly) electrode) the sub I(ads)/Au (poly) electrode exhibited a quasi-reversible two-electron reduction of O2 in alkaline media. The probable origin of the observed quasi-reversible behavior of the ORR is discussed. Experimental investigations were performed using cyclic and steady-state voltammetric, amperometric and coulometric techniques. 相似文献
7.
Noor Sahirah Muhazeli Nur Azmah Nordin Ubaid Ubaidillah Saiful Amri Mazlan Siti Aishah Abdul Aziz Nurhazimah Nazmi Iwan Yahya 《Materials》2020,13(24)
Conventional polyurethane foam has non-tunable sound absorption properties. Here, a magneto-induced foam, called magnetorheological (MR) foam, was fabricated with the feature of being able to tune sound absorption properties, primarily from the middle- to higher-frequency ranges. Three different samples of MR foams were fabricated in situ by varying the concentration of Carbonyl Iron Particles (CIPs) (0, 35, and 75 wt.%). The magnetization properties and tunable sound absorption characteristics were evaluated. From the magnetic saturation properties, the results showed very narrow and small coercivity of hysteresis loops relative to the soft magnetic properties of the CIPs. MR foam with 75 wt.% CIPs showed a higher magnetic saturation at 91.350 emu/g compared to MR foam with 35 wt.% CIPs at 63.896 emu/g. For tunable sound absorption testing, the effect of ‘shifting’ to higher frequency was also observed when the magnetic field was applied, which was ~10 Hz for MR foam with 35 wt.% CIPs and ~130 Hz for MR foam with 75 wt.% CIPs. As the latest evolution of semi-active noise control materials, the results from this study are valuable guidance for the advancement of MR-based devices. 相似文献
8.
9.
Rivard MJ Butler WM DeWerd LA Huq MS Ibbott GS Meigooni AS Melhus CS Mitch MG Nath R Williamson JF;American Association of Physicists in Medicine 《Medical physics》2007,34(6):2187-2205
Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical use as of January 10, 2005, and are posted on the Joint AAPM/RPC Brachytherapy Seed Registry. Consequently, the AAPM has prepared this supplement to the 2004 AAPM TG-43 update. This paper presents the AAPM-approved consensus datasets for these sources, and includes the following 125I sources: Amersham model 6733, Draximage model LS-1, Implant Sciences model 3500, IBt model 1251L, IsoAid model IAI-125A, Mentor model SL-125/ SH-125, and SourceTech Medical model STM1251. The Best Medical model 2335 103Pd source is also included. While the methodology used to determine these data sets is identical to that published in the AAPM TG-43U1 report, additional information and discussion are presented here on some questions that arose since the publication of the TG-43U1 report. Specifically, details of interpolation and extrapolation methods are described further, new methodologies are recommended, and example calculations are provided. Despite these changes, additions, and clarifications, the overall methodology, the procedures for developing consensus data sets, and the dose calculation formalism largely remain the same as in the TG-43U1 report. Thus, the AAPM recommends that the consensus data sets and resultant source-specific dose-rate distributions included in this supplement be adopted by all end users for clinical treatment planning of low-energy photon-emitting brachytherapy sources. Adoption of these recommendations may result in changes to patient dose calculations, and these changes should be carefully evaluated and reviewed with the radiation oncologist prior to implementation of the current protocol. 相似文献
10.