全文获取类型
收费全文 | 55篇 |
免费 | 6篇 |
专业分类
耳鼻咽喉 | 5篇 |
基础医学 | 1篇 |
口腔科学 | 2篇 |
临床医学 | 12篇 |
内科学 | 19篇 |
皮肤病学 | 2篇 |
神经病学 | 2篇 |
外科学 | 11篇 |
预防医学 | 2篇 |
药学 | 4篇 |
肿瘤学 | 1篇 |
出版年
2016年 | 4篇 |
2015年 | 4篇 |
2014年 | 7篇 |
2013年 | 6篇 |
2010年 | 2篇 |
2009年 | 4篇 |
2008年 | 1篇 |
2003年 | 2篇 |
2001年 | 2篇 |
1998年 | 2篇 |
1996年 | 2篇 |
1995年 | 1篇 |
1994年 | 4篇 |
1992年 | 3篇 |
1991年 | 2篇 |
1989年 | 2篇 |
1986年 | 2篇 |
1985年 | 5篇 |
1958年 | 1篇 |
1957年 | 1篇 |
1956年 | 1篇 |
1955年 | 2篇 |
1954年 | 1篇 |
排序方式: 共有61条查询结果,搜索用时 15 毫秒
1.
Renal Denervation for Treatment of Cardiac Arrhythmias: State of the Art and Future Directions 下载免费PDF全文
JEDRZEJ KOSIUK M.D. SEBASTIAN HILBERT M.D. EVGENY POKUSHALOV M.D. GERHARD HINDRICKS M.D. Ph.D. JONATHAN S. STEINBERG M.D. ANDREAS BOLLMANN M.D. Ph.D. 《Journal of cardiovascular electrophysiology》2015,26(2):233-238
Renal Denervation for Treatment of Cardiac Arrhythmias . It has now been more than a quarter of a century since modulation of the sympathetic nervous system was proposed for the treatment of cardiac arrhythmias of different origins. But it has also been some time since some of the early surgical attempts have been abandoned. With the development of ablation techniques, however, new approaches and targets have been recently introduced that have revolutionized our way of thinking about sympathetic modulation. Renal nerve ablation technology is now being successfully used for the treatment of resistant hypertension, but the indication spectrum might broaden and new therapeutic options might arise in the near future. This review focuses on the possible impact of renal sympathetic system modulation on cardiac arrhythmias, the current evidence supporting this approach, and the ongoing trials of this method in electrophysiological laboratories. We will discuss the potential roles that sympathetic modulation may play in the future. 相似文献
2.
CATHRIN THEIS M.D. HANKE MOLLNAU M.D. SEBASTIAN SONNENSCHEIN M.D. TORSTEN KONRAD M.D. EWALD HIMMRICH M.D. KARSTEN BOCK M.D. EBERHARD SCHULZ M.D. DENISE KÄMPFNER M.D. SIMON GERHARDT M.D. BLANCA QUESADA OCETE M.D. THOMAS MÜNZEL M.D. THOMAS ROSTOCK M.D. 《Journal of cardiovascular electrophysiology》2014,25(8):889-895
3.
ANDREAS METZNER M.D. PETER RAUSCH M.D. CHRISTINE LEMES M.D. BRUNO REISSMANN M.D. ALEXANDER BARDYSZEWSKI M.D. ROLAND TILZ M.D. ANDREAS RILLIG M.D. SHIBU MATHEW M.D. SEBASTIAN DEISS M.D. MASASHI KAMIOKA M.D. TOBIAS TOENNIS M.D. TINA LIN M.D. FEIFAN OUYANG M.D. KARL‐HEINZ KUCK M.D. ERIK WISSNER M.D. 《Journal of cardiovascular electrophysiology》2014,25(5):466-470
4.
5.
6.
SEBASTIAN GLOBITS M.D. SUZANNE RODLER M.D. HARALD MAYR M.D. ANTON MORITZ M.D. JOHANNES MLCZOCH M.D. DIETMAR GLOGAR M.D. ERNST WOLNER M.D. 《Journal of cardiac surgery》1992,7(1):9-16
Between April 1989 and March 1991, 237 CarboMedics bileaflet valve prosthesis carriers (165 aortic and 72 mitral valves, mean age 54.4 years) were studied prospectively with pulsed- and continuous-wave Doppler at a mean interval of 11.4 months following surgery in order to establish ranges of normal flow velocities and pressure gradients. Physical examination revealed no signs of prosthetic dysfunction or heart failure. Postoperative left ventricular function as measured by fractional shortening was 37% for aortic valve carriers and 30% for mitral valve carriers (p = NS). Mean peak velocity (+/- SD) across the aortic valve was 2.6 m/sec (+/- 0.4) and calculated instantaneous peak pressure gradient ranged from 11 to 58 mmHg (mean 28.1 +/- 10.3). It has to be emphasized that occasional patients with normally functioning valve prostheses can show unusual high gradients. Ring diameters between 21 and 27 mm showed no significant difference with regard to flow velocities and pressure gradients, whereas in 19-mm valves, significantly higher values could be demonstrated. The 123 aortic valve carriers with normal left ventricular function (fractional shortening greater than 25%) showed significantly higher pressure gradients than the 19 patients with reduced left ventricular function (28.6 +/- 11.6 mmHg vs 16.2 +/- 5.1 mmHg, p less than 0.05). In the mitral position, the mean of peak velocity (+/- SD) was 1.7 +/- 0.4 m/sec and pressure half-time was 108 +/- 26 msec, representing a calculated valve area between 1.4 to 3.1 cm2 (mean orifice size 2.1 +/- 0.5 cm2). No significant difference between valves of different sizes was found.(ABSTRACT TRUNCATED AT 250 WORDS) 相似文献
7.
8.
Primary Persistent Atrial Fibrillation: A Distinct Arrhythmia Subentity of an Ablation Population 下载免费PDF全文
9.
10.
RICHARD G. TROHMAN BRUCE L. WILKOFF TIMOTHY BYRNE SEBASTIAN COOK 《Pacing and clinical electrophysiology : PACE》1991,14(10):1448-1451
This report describes a patient with a chronic endocardial left ventricular pacing lead. To avoid the risk of future embolization, it was felt that the lead should be removed and right ventricular pacing established. The lead was carefully evaluated by transesophageal echocardiography to exclude adherent thrombus. Successful percutaneous lead extraction was accomplished without sequelae, thus avoiding the morbidity of a thoracotomy. 相似文献