Suppression of respiratory movement of the liver would be desirable for high-precision radiation therapy for liver tumors. We aimed to investigate the effect of our original device-free compressed shell fixation method and breathing instruction on suppression of respiratory movement. The characteristics of liver motion based on the movement of a fiducial marker were also analyzed.
Methods and Materials
First, respiratory amplitudes of the liver with the device-free compressed shell were analyzed from the data of 146 patients. The effect of this shell fixing method on liver movement was evaluated. Second, as another cohort study with 166 patients, interfractional internal motion of the liver for patients fixed in the shell was calculated using the fiducial marker coordinate data of images for position setting before daily irradiation. Third, in another 12 patients, intrafractional internal motion was calculated from the fiducial marker coordinate data using x-ray images before and after irradiation.
Results
The median respiratory movement without the shell, after fixing with the shell, and after instructing on the breathing method with the shell was 14.2 (interquartile range, 10.7-19.8), 11.5 (8.6-17.5), and 10.4 mm (7.3-15.8), respectively. Systematic and random errors of interfractional internal motion were all ≤2 mm in the left-right and anteroposterior directions and 3.7 and 3.0 mm, respectively, in the craniocaudal direction. Systematic and random errors of intrafractional internal motion were all ≤1.3 mm in the left-right and anteroposterior directions and 0.8 and 2.4 mm, respectively, in the craniocaudal direction.
Conclusions
The device-free compressed shell fixation method was effective in suppressing the respiratory movement of the liver. Irradiation position matching using the fiducial marker can correct the interfractional internal motion on each day, which would contribute to the reduction of the margin to be given around the target. 相似文献
Sentinel lymph node biopsy (SLNB) is a widely accepted standard procedure for patients with clinically localized melanoma. Melanoma prevalence and Clark's subtype differ between Asians and Caucasians. Here, we evaluated our experience on SLNB for cutaneous melanoma in a Japanese population. SLNB was performed for patients with melanoma between July 2000 and June 2014. We retrospectively analyzed 102 patients regarding association of clinicopathological features with sentinel lymph node (SLN) status, melanoma‐specific survival (MSS) and disease‐free survival (DFS). A positive SLN was significantly associated with primary Breslow thickness. Compared with 43 patients with negative SLN, 59 patients with positive SLN had significantly shorter MSS (5‐year survival rate, 94.3% vs 63.2%; P =0.0002) and DFS (5‐year survival rate, 92.7% vs 63.4%; P =0.0004). According to our subgroup analyses, nine patients with positive non‐SLN had significantly shorter MSS compared with 32 patients with negative non‐SLN (5‐year survival rate, 32.4% vs 68.5%; P =0.0273). The survival of 51 Japanese patients with acral lentiginous melanoma (ALM) was not inferior to the survival of patients with other Clark's subtype. Breslow thickness is an important factor for both MSS and DFS, and the status of SLN is the most predictive prognostic factor in Japanese patients with clinically localized melanomas, as in case of Caucasians. Features of ALM may be different between Asians and Caucasians. 相似文献
We report a case of a diaphragmatic hernia after a heart transplant operation. A 43-year-old woman, who underwent orthotropic heart transplantation for hypertrophic cadiomyopathy two year earlier, presented with vomiting and epigastric pain. A computed tomography scan showed that the stomach and transverse colon were dislocated in the left thoracic cavity. We diagnosed left diaphragmatic hernia incarceration and performed laparoscopic repair of the diaphragmatic hernia. A 12 × 8 cm diaphragmatic defect was found intraoperatively on the ventrolateral aspect of the left diaphragm, and the stomach with volvulus had herniated into the thorax through the defect. The hernia was considered to be iatrogenic. The diaphragmatic defect was large, and the diaphragm was thinning. We closed the defect by mesh repair. Laparoscopic mesh repair of the diaphragmatic hernia could be performed safely and with minimal invasiveness. 相似文献
Clinical and Experimental Nephrology - The association between N-terminal pro-brain natriuretic peptide (NT-proBNP) and stroke in Japanese hemodialysis (HD) outpatients is unclear. Therefore, in... 相似文献
A 23-year-old man was admitted for treatment of acute exacerbation of ileitis and perianal abscess caused by Crohn's disease. After incision and drainage of the abscess, coupled with antibiotic therapy, 6-mercaptopurine (6-MP) was commenced. His white blood cell (WBC) count on day 12 after initiation of 6-MP was not decreased. However, on day 24 he was re-admitted because of severe myelosuppression (WBC: 300/microl), which was complicated by the recurrence of the perianal abscess. Myelosuppression was prolonged and required the administration of granulocyte colony stimulating factor (G-CSF). G-CSF was continued for 17 days to achieve recovery of his WBC count to a normal level. 相似文献
BACKGROUND AND PURPOSE: Dot-like low intensity spots (dot-like hemosiderin spots: dotHSs) on gradient echo T2*-weighted MRI have been histologically diagnosed to represent old cerebral microbleeds associated with microangiopathies. They have also been correlated to the fragility of small vessels and the tendency to bleed. Therefore, a substantial number of dotHSs might be associated with a large-sized, deep intracerebral hematoma (ICH). On the other hand, dotHSs may reflect old microbleeds that did not enlarge to symptomatic size. METHODS: To investigate how dotHSs are related to the size (maximal diameter) of primary deep ICH, we analyzed the diameter and the number of dotHSs in 151 patients with deep ICH not associated with subarachnoid hemorrhage or intraventricular hemorrhage (75 males and 76 females, age ranged from 37 to 90 [65.7 +/- 11.3 years old] who were consecutively admitted to Hakodate Municipal Hospital. The hazard ratio (HR) for a maximal diameter of deep ICH < or =2 cm was estimated, using the number of dotHSs and risk factors for stroke. RESULTS: The number of dotHSs associated with the diameter < or =2 cm was 9.2 +/- 11.5, significantly larger than that with the diameter > or =2 cm (4.7 +/- 7.0, P= .012). Multivariate analysis revealed that a maximal diameter of deep ICH of < or =2 cm was found in patients with dotHS (HR, 3.7; 95% confidence interval [CI], 1.4-10.1; P= .009). CONCLUSION: Though small sample size limited the power of our analyses, these findings suggest that the number of dotHSs may be associated with a small diameter of deep ICH. 相似文献
Background: The authors previously reported that, during isoflurane anesthesia, electroencephalographic bicoherence values changed in a fairly restricted region of frequency versus frequency space. The aim of the current study was to clarify the relation between electroencephalographic bicoherence and the isoflurane concentration.
Methods: Thirty elective abdominal surgery patients (male and female, aged 34-77 yr, American Society of Anesthesiologists physical status I-II) were enrolled. After electroencephalogram recording with patients in an awake state, anesthesia was induced with 3 mg/kg thiopental and maintained with oxygen and isoflurane. Continuous epidural anesthesia with 80-100 mg/kg 1% lidocaine was also administered. Using software they developed, the authors continuously recorded the FP1-A1 lead of the electroencephalographic signal and expired isoflurane concentration to an IBM-PC compatible computer. After confirming the steady state of each isoflurane (end-tidal concentration at 0.3, 0.5, 0.7, 0.9, 1.1, 1.3, and 1.5%), electroencephalographic bicoherence values were calculated.
Results: In a light anesthetic state, electroencephalographic bicoherence values were low (generally <= 15.0%). At increased concentrations of isoflurane, two peaks of electroencephalographic bicoherence emerged along the diagonal line (f1 = f2). The peak emerged at around 4.0 Hz and grew higher as isoflurane concentration increased until it reached a plateau (43.8 +/- 3.5%, mean +/- SD) at isoflurane 0.9%. The other peak, at about 10.0 Hz, also became significantly higher and reached a plateau (32.6 +/- 9.2%) at isoflurane 0.9%; at isoflurane 1.3%, however, this peak slightly decreased. 相似文献