首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   75篇
  免费   3篇
内科学   1篇
特种医学   1篇
外科学   73篇
综合类   1篇
预防医学   2篇
  2023年   1篇
  2022年   1篇
  2018年   5篇
  2017年   3篇
  2016年   1篇
  2014年   1篇
  2013年   7篇
  2012年   4篇
  2011年   6篇
  2010年   1篇
  2008年   1篇
  2002年   2篇
  2001年   7篇
  2000年   2篇
  1999年   7篇
  1998年   8篇
  1997年   2篇
  1996年   2篇
  1995年   3篇
  1992年   1篇
  1989年   1篇
  1988年   4篇
  1987年   2篇
  1986年   4篇
  1984年   1篇
  1983年   1篇
排序方式: 共有78条查询结果,搜索用时 15 毫秒
1.
2.
Three cases are reported where continuous lumbosacral block was performed using a catheter through an epidural needle technique. Good unilateral lower limb surgical anaesthesia was achieved in all three cases with successful blockade of the lumbar and sacral plexuses. A 17-gauge Tuohy needle was positioned between the transverse processes of L4 and L5 and an epidural catheter inserted into the space between the quadratus lumborum and psoas muscles. Forty to seventy millilitres of local anaesthetic were injected and resulted in good surgical anaesthesia within 12-20 min. Radiographic studies in these patients confirmed placement of the catheter in close proximity to the lumbosacral plexus. Experience in a further 12 cases is also reported. There were no side-effects. The technique is successful and is recommended when unilateral lower limb anaesthetic is required and when spinal and epidural anaesthesia are contraindicated.  相似文献   
3.
4.
5.
6.
Foreign body ingestions are quite common and most often will uneventfully pass in stool, however, some ingestions, can lead to complications such as obstruction. If left untreated, this can lead to perforation and fistula formation. Hence, threshold for intervention should be low and diagnostic imaging can assist with treatment decisions. We present to you a case of 17-year-old male with non-verbal autism with an unusual hollow foreign body ingestion leading to small bowel obstruction.  相似文献   
7.
8.
9.
Summary An assessment of energy expenditure has been made in 50 male textile workers and 30 male office cleaners. There was a statistically significant difference (P < 0.001) in energy expenditure between textile workers and office cleaners amounting to 12 to 16%. While 33.3% of the textile group complained of chest disorders, none of the cleaners had such a complaint. FEV1 and FVC values of the textile workers were significantly lower (P < 0.01) compared to those of the controls. There were no differences in body weight, lean body mass and socio-economic conditions of the two groups, however, the textile workers were younger and taller than the unexposed group. Exposure to cotton dust and respiratory and ventilatory impairments are suspected of causing a reduction in the energy expenditure of the textile workers  相似文献   
10.

Study objective

The purpose of this study was to assess whether application of dorsal table tilt and body rotation to a parturient seated for neuraxial anesthesia increased the size of the paramedian target area for neuraxial needle insertion.

Setting

Labor and Delivery Room.

Patients

Thirty term pregnant women, ASA I–II, scheduled for an elective C‐section delivery.

Interventions

Lumbar ultrasonography was performed in four seated positions: (F) lumbar flexion; (FR) as in position F with right shoulder rotation; (FT) as in position F with dorsal table‐tilt; (FTR) as in position F with dorsal table‐tilt combined with right shoulder rotation.

Measurements

For each position, the size of the ‘target area’, defined as the visible length of the posterior longitudinal ligament was measured at the L3‐L4 interspace.

Main results

The mean posterior longitudinal ligament was 18.4 ± 4 mm in position F, 18.9 ± 5.5 mm in FR, 19 ± 5.3 mm in FT, and 18 ± 5.2 mm in FTR. Mean posterior longitudinal ligament length was not significantly different in the four positions.

Conclusions

These data show that the positions studied did not increase the target area as defined by the length of the posterior longitudinal ligament for the purpose of neuraxial needle insertion in obstetric patients. The maneuvers studied will have limited use in improving spinal needle access in pregnant women.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号