Background: Anesthetic preconditioning (APC) with sevoflurane reduces myocardial ischemia-reperfusion injury. The authors tested whether two brief exposures to sevoflurane would lead to a better preconditioning state than would a single longer exposure and whether dual exposure to a lower (L) concentration of sevoflurane would achieve an outcome similar to that associated with a single exposure to a higher (H) concentration.
Methods: Langendorff-prepared guinea pig hearts were exposed to 0.4 mm sevoflurane once for 15 min (H1-15; n = 8) or 0.4 mm (H2-5; n = 8) or 0.2 mm sevoflurane (L2-5; n = 8) twice for 5 min, with a 5-min washout period interspersed. Sevoflurane was then washed out for 20 min before 30 min of global no-flow ischemia and 120 min of reperfusion. Control hearts (n = 8) were not subjected to APC. Left ventricular pressure was measured isovolumetrically. Ventricular infarct size was determined by tetrazolium staining and cumulative planimetry. Values are expressed as mean +/- SD.
Results: The authors found a better functional return and a lesser percentage of infarction on reperfusion in H2-5 (28 +/- 9%) than in H1-15 (36 +/- 8%; P < 0.05), L2-5 (43 +/- 6%; P < 0.05), or control hearts (52 +/- 7%; P < 0.05). 相似文献
Endocarditis secondary to Hemophilus parainfluenzae is an uncommon entity that appears to be increasing in frequency, perhaps due to improved laboratory isolation techniques. Although controversial, most of the published literature recommends a penicillin, with or without concomitant gentamicin, as definitive therapy. We report the first successful use of the third-generation cephalosporin ceftizoxime in an ampicillin-allergic patient. A 55-year-old white female was hospitalized after 5 days of experiencing fever, chills, nausea, and vomiting. A cardiac echocardiogram revealed a large mitral valve vegetation, and the patient was treated with intravenous ampicillin, gentamicin, and clindamycin. Two weeks after emergency mitral valve replacement the patient developed spiking fevers and a macular, erythematous rash while receiving ampicillin. Ceftizoxime was initiated and continued to complete a 4-week period of intravenous antibiotics. Follow-up at 14 months showed no further evidence of infection. Ceftizoxime appears efficacious in eradicating H. parainfluenzae in patients allergic to penicillin. 相似文献
Flow cytometry is an accurate but expensive method to determine absolute CD4 cell counts. We compared different methods to measure absolute CD4 counts in blood samples from HIV-infected and uninfected subjects using a research/clinical flow cytometer (FACScan); a dedicated clinical instrument (FACSCount); and a volumetric, mobile, open-system flow cytometer equipped with 3 fluorescence and 2 light scatter detectors (Cyflow SL blue). The FACScan and Cyflow were used as single-platform instruments, but they differ in running cost, which is a central factor for resource-poor settings. Direct volumetric and bead-based CD4 measurements on the Cyflow were compared with 2 bead-based single-platform CD4 measurements on the FACSCount and on FACScan (TruCount) in "Le Dantec" Hospital, Dakar, Senegal, using whole blood samples from 102 HIV+ and 28 HIV- subjects. The agreement between the various measurement methods was evaluated by Bland-Altman analysis. Volumetric CD4 measurements on the Cyflow using a no-lyse-no-wash (NLNW) procedure and a lyse-no-wash (LNW) procedure correlated well with each other (R2 = 0.98) and with CD4 measurements on the FACSCount (R2 = 0.97) and FACScan (R2 = 0.97), respectively. Red blood cell lysis had no negative effect on the accuracy of absolute CD4 counting on the Cyflow. An excellent correlation was observed between bead-based CD4 measurements on the Cyflow and CD4 measurements on the FACSCount (R2 = 0.99) and FACScan (R2 = 0.99). Rigid internal and external quality control monitoring and adequate training of technicians were considered essential to generate accurate volumetric CD4 measurements on the Cyflow. 相似文献