排序方式: 共有40条查询结果,搜索用时 15 毫秒
1.
Collettini Federico Schreiber Nadja Schnapauff Dirk Denecke Timm Wust Peter Schott Eckart Hamm Bernd Gebauer Bernhard 《Strahlentherapie und Onkologie》2015,191(5):405-412
Strahlentherapie und Onkologie - The purpose of the present study was to evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) in patients with unresectable... 相似文献
2.
3.
Dirk Schnapauff MD Elke Zimmermann MD Marc Dewey MD 《Seminars in Ultrasound, CT and MRI》2008,29(3):167-175
Coronary computed tomography angiography is an emerging imaging technique that has attracted much scientific attention over the past years. Improved scanner technology and dedicated protocols have made noninvasive coronary a reliable diagnostic test in patients with suspected coronary artery disease (CAD). Several technical steps such as the introduction of 64-slice scanners, multisegment reconstruction, and dual-source computed tomography have substantially improved temporal and spatial resolution. With these sophistications, coronary computed tomography angiography enables reliable exclusion of CAD in patients with low to intermediate pretest probability of having CAD or with inconsistent ischemia test results. 相似文献
4.
5.
6.
7.
8.
Jan Holger Rothe Christian Grieser Lukas Lehmkuhl Dirk Schnapauff Carmen Perez Fernandez Martin H. Maurer Axel Mussler Bernd Hamm Timm Denecke Ingo G. Steffen 《European journal of radiology》2013
Objective
To compare different three-dimensional volumetric algorithms (3D-algorithms) and RECIST for size measurement and response assessment in liver metastases from colorectal and pancreatic cancer.Methods
The volumes of a total of 102 liver metastases in 45 patients (pancreatic cancer, n = 22; colon cancer, n = 23) were estimated using three volumetric methods (seeded region growing method, slice-based segmentation, threshold-based segmentation) and the RECIST 1.1 method with volume calculation based on the largest axial diameter. Each measurement was performed three times by one observer. All four methods were applied to follow-up on 55 liver metastases in 29 patients undergoing systemic treatment (median follow-up, 3.5 months; range, 1–10 months). Analysis of variance (ANOVA) with post hoc tests was performed to analyze intraobserver variability and intermethod differences.Results
ANOVA showed significant higher volumes calculated according to the RECIST guideline compared to the other measurement methods (p < 0.001) with relative differences ranging from 0.4% to 41.1%. Intraobserver variability was significantly higher (p < 0.001) for RECIST and threshold based segmentation (3.6–32.8%) compared with slice segmentation (0.4–13.7%) and seeded region growing method (0.6–10.8%). In the follow-up study, the 3D-algorithms and the assessment following RECIST 1.1 showed a discordant classification of treatment response in 10–21% of the patients.Conclusions
This study supports the use of volumetric measurement methods due to significant higher intraobserver reproducibility compared to RECIST. Substantial discrepancies in tumor response classification between RECIST and volumetric methods depending on applied thresholds confirm the requirement of a consensus concerning volumetric criteria for response assessment. 相似文献9.
This study was performed to prospectively compare multidetector computed tomography (MDCT) with 16 simultaneous sections and
magnetic resonance imaging (MRI) for the assessment of global right ventricular function in 50 patients. MDCT using a semiautomatic
analysis tool showed good correlation with MRI for end-diastolic volume (EDV, r = 0.83, p < 0.001), end-systolic volume (ESV, r = 0.86, p < 0.001) and stroke volume (SV, r = 0.74, p < 0.001), but only a moderate correlation for the ejection fraction (EF, r = 0.67, p < 0.001). Bland Altman analysis revealed a slight, but insignificant overestimation of EDV (4.0 ml, p = 0.08) and ESV (2.4 ml, p = 0.07), and underestimation of EF (0.1%, p = 0.92) with MDCT compared with MRI. All limits of agreement between both modalities (EF: ±15.7%, EDV: ±31.0 ml, ESV: ±18.0 ml)
were in a moderate but acceptable range. Interobserver variability of MDCT was not significantly different from that of MRI.
For MDCT software, the post-processing time was significantly longer (19.6 ± 5.8 min) than for MRI (11.8 ± 2.6 min, p < 0.001). Accurate assessment of right ventricular volumes by 16-detector CT is feasible but still rather time-consuming. 相似文献
10.
Dirk Schnapauff MD Martin Zeile MD Manuel Ben Niederhagen MD Barbara Fleige MD Per‐Ulf Tunn MD Bernd Hamm MD Oliver Dudeck MD 《Journal of magnetic resonance imaging : JMRI》2009,29(6):1355-1359