排序方式: 共有29条查询结果,搜索用时 15 毫秒
1.
Functional mapping of color processing by magnetic resonance imaging of responses to selective P- and M-pathway stimulation 总被引:2,自引:0,他引:2
Andreas Kleinschmidt Barry B. Lee Martin Requardt Jens Frahm 《Experimental brain research. Experimentelle Hirnforschung. Expérimentation cérébrale》1996,110(2):279-288
Magnetic resonance imaging sensitized to activity-related changes in cerebral blood oxygenation was performed to map responses to selective stimulation of the parvo- and magnocellular visual pathways in calcarine and adjacent ventral occipital cortex of human subjects. In a repetitive stimulation protocol isoluminant chromatic or isochromatic luminance modulation was alternated with steady light of the same mean chromaticity and luminance as a reference condition. While no significant effects were observed for diffuse luminance modulation, two consistent cortical foci responded to isoluminant chromatic stimulation. A strong response was obtained in calcarine cortex at both 2 and 10 Hz, and even for selective S-cone stimulation. A second weaker colorsensitive response was seen bilaterally in the collateral sulcus. Thus, the data not only confirm color-sensitive activation in the collateral sulcus elicited in previous studies by selective cognitive tasks, but additionally demonstrate color-sensitive activation in primary visual cortex. With stimuli defined according to electrophysiological response properties of early visual processing stages, this study complements phenomenological or cognitive approaches in functional mapping of the human visual system. 相似文献
2.
R Janka F Fellner M Requardt C Fellner H Greess W Lang W Bautz 《R?ntgenpraxis; Zeitschrift für radiologische Technik》1999,52(1):15-18
Magnetic resonance angiography (MRA) is increasingly used as a non-invasive alternative to digital subtraction angiography (DSA). Besides plain time-of-flight (TOF) and phase contrast (PC) MRA a new MRA technique using positive contrast agent has been introduced recently. A fast 3D gradient-echo sequence is applied to reach a significant reduction of measurement time for acquisition of the MRA within the first pass of the contrast agent, thereby avoiding venous overlap. A significant progress was yielded by MR systems allowing manual table movement for examination of the pelvis and the lower limbs in one examination with a single contrast agent bolus. However, in this case it is necessary to have a coworker in the examination room moving the table manually. In this paper we report a prototype system which allows automatic table movement ("floating table"). Using this novel system we examined a patient with an aneurysm of the abdominal aorta and peripheral arterial occlusive disease (PAOD). Diagnostic results of contrast enhanced MRA and DSA were equivalent. In summary, the automatic floating table system introduced in this paper allows comfortable non-invasive examination of pelvic and lower limb arteries. The value of this technique in comparison to DSA has to be determined in future studies. 相似文献
3.
Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths 总被引:1,自引:0,他引:1
RATIONALE AND OBJECTIVES: To characterize and compare commercially available contrast media (CM) for magnetic resonance imaging (MRI) in terms of their relaxivity at magnetic field strengths ranging from 0.47 T to 4.7 T at physiological temperatures in water and in plasma. Relaxivities also were quantified in whole blood at 1.5 T. METHODS: Relaxivities of MRI-CM were determined by nuclear magnetic resonance (NMR) spectroscopy at 0.47 T and MRI phantom measurements at 1.5 T, 3 T, and 4.7 T, respectively. Both longitudinal (T1) and transverse relaxation times (T2) were measured by appropriate spin-echo sequences. Nuclear magnetic resonance dispersion (NMRD) profiles were also determined for all agents in water and in plasma. RESULTS: Significant dependencies of relaxivities on the field strength and solvents were quantified. Protein binding leads to both increased field strength and solvent dependencies and hence to significantly altered T1 relaxivity values at higher magnetic field strengths. CONCLUSIONS: Awareness of the field strength and solvent associated with relaxivity data is crucial for the comparison and evaluation of relaxivity values. Data observed at 0.47 T can thus be misleading and should be replaced by relaxivities measured at 1.5 T and at 3 T in plasma at physiological temperature. 相似文献
4.
Our purpose was to investigate the potential of an experimental animal coil using a commercial MRI unit to delineate the anatomical structure of the human brain stem. Three formaldehyde-fixed brain-stem specimens were examined by MRI and sectioned perpendicular to their longitudinal axis. The images were compared with gross anatomy and myelin-stained histological sections. Fibre tracts and nuclei which were not evident on examination of the unstained specimen were readily identified by MRI. Due to its inherent grey/white matter contrast, MRI with a highresolution coil delineates anatomical structures in a way comparable to the myelin-stained histological sections. However, pigmented structures, readily visible on examination of the unstained specimen were discernible on neither MRI nor on myelin-stained sections. The excellent anatomical detail and grey/white matter contrast provided by these images could make MRI a useful adjunct to the pathologist investigating brain disease. 相似文献
5.
A switchable-array surface coil for magnetic resonance (MR) imaging of the spine has been built that enables the user to change the working size of the coil depending on the volume of interest. The prototype has achieved similar image quality to that obtained with conventional coils of equal size. This type of antenna may reduce the number of individual coils necessary for a high-quality MR imaging study. 相似文献
6.
János Martos Dirk Petersen Uwe Klose Hermann Requardt Rainer Buchholz Petra Ohneseit Martin Schabet Karsten Voigt 《Journal of neuro-oncology》1992,14(3):207-211
MR imaging of the rat brain has become an increasingly frequently used method in experimental neuroradiology. On a generally available 1.5 T whole body tomograph, supplemented with an individually made small coil and a special SE sequence we obtained fairly fine images of the structures of the rat brain. With gadolinium-DTPA, we were able to visualize posterior fossa and cervical leptomeningeal growth of intrathecally injected B16 melanoma in nude rats. Using MRI to follow experimental leptomeningeal metastasis, may provide a new means for diagnostic evaluation and preclinical testing of treatment modalities. 相似文献
7.
Elisabeth Schültke Stefan Fiedler Lissa Ogieglo Paul Crawford Thierry Brochard Herwig Requardt Bernhard Juurlink 《European journal of radiology》2010,73(3):677-681
Background
K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients.Materials and methods
This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France.Results
After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix®), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5 mm diameter. 相似文献8.
Requardt H 《The British journal of radiology》2006,79(937):17-23
The challenges to healthcare systems around the world are primarily impacted by two topics: demographic factors and progress in medicine. An ageing population inherently needs more medical services which add financial burdens, in particular, to public healthcare. Since the level of medical education is growing at the same time, we are observing an increased demand for sophisticated (in general expensive) medicine. Drastic changes in financing seem unavoidable. Multiple diagnoses, repeated examinations, trial-and-error, overcapacities and other signs of missing economical considerations are reinforced by reimbursement systems. In a world where, in principle, all information is available everywhere, more than a patient's history should be accessible. Other industries have knowledge management systems in place that make state-of-the-art expertise available everywhere. Intelligent patient databases could consist of learning cycles that (i) enable the individual to benefit from structured knowledge, in addition to personal experience of the physician, and (ii) use the knowledge generated from the individual to extend the database. The novel area of molecular medicine fits perfectly well into these scenarios. Only attached to an IT backbone can the flood of information be managed in a beneficial way. Efficiency improvements in healthcare address the needs of all parties in the system: patients, providers, and payers. The opportunities, however, can only materialize if everyone is prepared to change. IT will set the standards for the biggest challenge in healthcare: The paradigm shift in medicine. 相似文献
9.
Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience 总被引:8,自引:0,他引:8
Fenchel M Requardt M Tomaschko K Kramer U Stauder NI Naegele T Schlemmer HP Claussen CD Miller S 《Journal of magnetic resonance imaging : JMRI》2005,21(5):596-603
PURPOSE: To demonstrate the feasibility of detecting atherosclerotic vascular disease using an innovative magnetic resonance angiography (MRA) protocol in combination with a dedicated whole-body MR scanner with new surface coil technology. MATERIALS AND METHODS: A total of 10 volunteers and eight patients with peripheral arterial occlusive disease (PAOD) were examined at 1.5 T. Conventional digital subtraction angiography (DSA) of the symptomatic region was available as a reference standard in all eight patients. Depending on subjects' size, four to five three-dimensional data sets were acquired using an adapted injection protocol. Images were assessed independently by two readers for vascular pathology. Additionally, signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were measured. RESULTS: Whole-body MRA yielded excellent sensitivity and specificity of more than 95% for both readers with high interobserver agreement (k = 0.93). Surface coil signal reception rendered a high SNR (mean 151.28 +/- 54.04) and CNR (mean 120.75 +/- 46.47). Despite lower SNR and CNR of the cranial and cervical vessels, a two-step injection protocol exhibited less venous superposition and therefore proved to be superior compared to single-bolus injection. CONCLUSION: Our approach provides accurate noninvasive high-resolution imaging of systemic atherosclerotic disease, covering the arterial vasculature from intracranial arteries to distal runoff vessels. The recently introduced MR scanner and coil technology is feasible to significantly increase the performance of whole-body MRA. 相似文献
10.
Janka R Fellner F Fellner C Requardt M Reykowski A Lang W Bautz W 《European radiology》2000,10(11):1745-1749
In this paper we introduce a phased-array coil dedicated for MRA of peripheral arteries which covers the upper and lower
legs. The structure of this coil includes a solid cabinet with four flexible wings forming a “T.” The flexibility of the wings
allows adaptation to the individual leg size. There are eight circularly polarized channels, four on each side. This coil
is compatible with other surface coils. For MRA of peripheral arteries, it is combined with the body phased-array coil and
the spine array coil which cover the lower abdomen and the pelvis. We examined six patients using this coil combination. The
image quality, the signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of these examinations were compared with
that of peripheral MRA examinations obtained with the body resonator. Image quality with the array coil was considerably improved
in comparison with the body resonator examinations. The SNR and CNR increased approximately 100 %. The handling of this coil
was very quick and simple, similar to the procedure with other surface coils. The use of dedicated phased-array coils for
peripheral MRA may be an important step toward the establishment of MR digital subtraction angiography (DSA) as a non-invasive
alternative to intra-arterial DSA in the visualization of peripheral arteries. Its potential has to be evaluated in future
studies.
Received: 27 October 1999; Revised: 10 April 2000; Accepted: 14 April 2000 相似文献