首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   2篇
基础医学   1篇
口腔科学   1篇
临床医学   1篇
特种医学   1篇
外科学   7篇
综合类   1篇
肿瘤学   3篇
  2022年   1篇
  2021年   6篇
  2018年   4篇
  2017年   2篇
  2011年   1篇
  2004年   1篇
排序方式: 共有15条查询结果,搜索用时 15 毫秒
1.
Disposable N95 respirator masks are the current standard for healthcare worker respiratory protection in the COVID-19 pandemic. In addition to shortages, qualitative fit testing can have low sensitivity for detecting poor fit, leading to inconsistent protection. Multiple groups have developed alternative solutions such as modified snorkel masks to overcome these limitations, but validation of these solutions has been lacking. We sought to determine if N95s and snorkel masks with attached high-efficiency filters provide consistent protection levels in healthcare workers and if the addition of positive pressure via an inexpensive powered-air purifying respirator to the snorkel mask would provide enhanced protection. Fifty-one healthcare workers who were qualitatively fitted with N95 masks underwent quantitative mask fit testing according to a simulated workplace exercise protocol. N95, snorkel masks with high-efficiency filters and snorkel masks with powered-air purifying respirators were tested. Respiratory filtration ratios were collected for each step and averaged to obtain an overall workplace protocol fit factor. Failure was defined as either an individual filtration ratio or an overall fit factor below 100. N95s and snorkel masks with high-efficiency filters failed one or more testing steps in 59% and 20% of participants, respectively, and 24% and 12% failed overall fit factors, respectively. The snorkel masks with powered-air purifying respirators had zero individual or overall failures. N95 and snorkel masks with high-efficiency filter respirators were found to provide inconsistent respiratory protection in healthcare workers.  相似文献   
2.
As the clinical advantages of vapor anesthesia (VA) for sedation of patients in ICU become more apparent, the ergonomics, economy and safety issues need to be better addressed. Here we describe the use of a new commercial digital in-line anesthetic vaporizer that can be attached to the inspiratory limb of a ventilator. If used with a simple, and easily assembled secondary circuit and anesthetic reflector, the circuit remains remote from the patient, the VA consumption approaches a physical minimum, VA level is controlled and monitored, and the tidal volume size is not limited.  相似文献   
3.
Objective:A new Bayesian penalized likelihood reconstruction algorithm for positron emission tomography (PET) (Q.Clear) is now in clinical use for fludeoxyglucose (FDG) PET/CT. However, experience with non-FDG tracers and in special patient populations is limited. This pilot study aims to compare Q.Clear to standard PET reconstructions for 18F sodium fluoride (18F-NaF) PET in obese patients.Methods:30 whole body 18F-NaF PET/CT scans (10 patients with BMI 30–40 Kg/m2 and 20 patients with BMI >40 Kg/m2) and a NEMA image quality phantom scans were analyzed using ordered subset expectation maximization (OSEM) and Q.Clear reconstructions methods with B400, 600, 800 and 1000. The images were assessed for overall image quality (IQ), noise level, background soft tissue, and lesion detectability, contrast recovery (CR), background variability (BV) and contrast-to-noise ratio (CNR) for both algorithms.Results:CNR for clinical cases was higher for Q.Clear than OSEM (p < 0.05). Mean CNR for OSEM was (21.62 ± 8.9), and for Q.Clear B400 (31.82 ± 14.6), B600 (35.54 ± 14.9), B800 (39.81 ± 16.1), and B1000 (40.9 ± 17.8). As the β value increased the CNR increased in all clinical cases. B600 was the preferred β value for reconstruction in obese patients. The phantom study showed Q.Clear reconstructions gave lower CR and lower BV than OSEM. The CNR for all spheres was significantly higher for Q.Clear (independent of β) than OSEM (p < 0.05), suggesting superiority of Q.Clear.Conclusion:This pilot clinical study shows that Q.Clear reconstruction algorithm improves overall IQ of 18F-NaF PET in obese patients. Our clinical and phantom measurement results demonstrate improved CNR and reduced BV when using Q.Clear. A β value of 600 is preferred for reconstructing 18F-NaF PET/CT with Q.Clear in obese patients.Advances in knowledge:18F-NaF PET/CT is less susceptible to artifacts induced by body habitus. Bayesian penalized likelihood reconstruction with18F-NaF PET improves overall IQ in obese patients.  相似文献   
4.
5.
6.
7.
8.
Older patients with lower-risk hormone receptor-positive (HR+) breast cancer are frequently offered both radiotherapy (RT) and endocrine therapy (ET) after breast-conserving surgery (BCS). A survey was performed to assess older patients’ experiences and perceptions regarding RT and ET, and participation interest in de-escalation trials. Of the 130 patients approached, 102 eligible patients completed the survey (response rate 78%). The median age of respondents was 74 (interquartile range 71–76). Most participants (71%, 72/102) received both RT and ET. Patients felt the role of RT and ET, respectively, was to: reduce ipsilateral tumor recurrence (91%, 90/99 and 62%, 61/99) and improve survival (56%, 55/99 and 49%, 49/99). More patients had significant concerns regarding ET (66%, 65/99) than RT (39%, 37/95). When asked which treatment had the most negative effect on their quality of life, the results showed: ET (35%, 25/72), RT (14%, 10/72) or both (8%, 6/72). Participants would rather receive RT (57%, 41/72) than ET (43%, 31/72). Forty-four percent (44/100) of respondents were either, “not comfortable” or “not interested” in participating in potential de-escalation trials. Although most of the adjuvant therapy de-escalation trials evaluate the omission of RT, de-escalation studies of ET are warranted and patient centered.  相似文献   
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号