Retinal fundus photographs are employed as standard diagnostic tools in ophthalmology. Serial photographs of the flow of fluorescein and indocyanine green (ICG) dye are used to determine the areas of the retinal lesions. For objective measurements of features, the registration of the images is a necessity. In this paper, we employ optimization techniques for registration with the help of 2-parameter translational motion model of retinal angiograms, based on non-linear pre-processing (Wiener filtering and morphological gradient) and computation of the similarity criteria for the alignment of the two gradient images for any given rigid transformation. The optimization methods are effectively employed to minimize the similarity criterion.
The presence of noise, the variations in the background and the temporal variation of the fluorescence level pose serious problems in obtaining a robust registration of the retinal images. Moreover, local search strategies are not robust in the case of ICG angiograms, even if one uses a multiresolution approach.
The present work makes a systematic comparison of different optimization techniques, namely the minimization method derived from the optical flow formulation, the Nelder-Mead local search and the HCIAC ant colony metaheuristic, each optimizing a similarity criterion for the gradient images. The impact of the resolution and median filtering of gradient image is studied and the robustness of the approaches is tested through experimental studies, performed on macular fluorescein and ICG angiographies.
Our proposed optimization techniques have shown interesting results especially for high resolution difficult registration problems. Moreover, this approach seems promising for affine (6-parameter motion model) or elastical registrations. 相似文献
In obstetrics and gynaecology, as well as in many other fields of medicine, ultrasound has become an indispensable diagnostic tool. Ultrasound training, however, still lacks proper quality assessment and control. In fact, in prenatal diagnostics most fetal anomalies requiring diagnosis during pregnancy are extremely rare. Therefore, effective training opportunities are limited to the very few medical centres which treat many such cases. Ultrasound simulator-based training, as performed with the Sonofit Sonotrainer, has been demonstrated to partly overcome this dilemma. In this article, the authors summarize their experience in using and evaluating various teaching concepts after the implementation of the ultrasound simulator under different conditions. Furthermore, an overview of the advantages of the Sonotrainer-based ultrasound training and its acceptance among trainees is provided. The authors also focus on aspects of quality assessment in gynaecological and prenatal ultrasound. 相似文献
A retrospective chart review of 43 patients who underwent technetium 99m (Tc-99m) sestamibi scans from June 1995 to January 1997 was performed. Only those who underwent subsequent parathyroid exploration with excision were included in the study. Twenty subjects (13 women and seven men) were included in the study. Ages ranged from 21 to 84 years (mean, 58 years). All patients had laboratory values and clinical findings consistent with primary hyperparathyroidism. Two patients had preoperative magnetic resonance imaging (MRI) scans (one patient with recurrent disease), and one had a preoperative computed tomography (CT) scan. The remaining patients had the sestamibi scan as the only preoperative localization study. There were 18 pathologic diagnoses of parathyroid adenoma and two of parathyroid hyperplasia. Sestamibi failed to correctly identify the location of the parathyroid lesion in two cases. In 18 cases the preoperative sestamibi scan correctly localized the lesion, a predictive value of 90%. We conclude that the Tc-99m sestamibi scan is an accurate preoperative tool that can be used as a single modality to localize parathyroid adenomas. 相似文献
PURPOSE: To investigate whether balloon angioplasty of the superficial femoral artery (SFA) increases serum levels of C5a and whether C5a predicts risk of restenosis. METHODS: C5a antigen was measured at baseline and 8 hours after intervention in 131 consecutive patients (76 women; median age 72 years) with intermittent claudication who underwent successful primary SFA balloon angioplasty. Patients were followed for a median 10 months [interquartile range (IQR) 6 to 14] for the occurrence of >50% restenosis by duplex ultrasound. RESULTS: Median C5a levels increased significantly from 39.7 ng/mL (IQR 27.8 to 55.0) at baseline to 53.8 ng/mL (IQR 35.6 to 85.1, p<0.001) 8 hours post intervention. During the follow-up period, 70 (53%) patients developed restenosis. Increasing levels of C5a (quartiles) at baseline were significantly associated with an increased risk for restenosis (p=0.0092). Adjusted hazard ratios (95% confidence intervals) for restenosis with increasing quartiles of baseline serum C5a levels were 1.24 (0.60 to 2.58), 1.93 (0.95 to 3.93), and 2.08 (1.02 to 4.21), respectively, compared to the lowest quartile. This effect was independent of nonspecific inflammation as reflected by plasma levels of C-reactive protein. CONCLUSION: Inflammatory mechanisms play a major role in the development of restenosis after angioplasty. The complement component C5a exerts strong chemotactic and proinflammatory effects. Enhanced complement activation prior to PTA, as measured by higher levels of C5a, was significantly associated with restenosis after SFA balloon angioplasty. Pathways of complement inhibition thus may be worth investigating with respect to improving patency rates. 相似文献