Introduction: Allergic rhinitis is a common condition with increasing prevalence and is associated with several comorbid disorders such as bronchial asthma and atopic dermatitis. If allergen avoidance is not possible, allergen-specific immunotherapy is the only causal treatment option.
Areas covered: This review focuses on current treatments and the future outlook for allergic rhinitis. Pharmacotherapy includes mast cell stabilizers, antihistamines, glucocorticosteroids (GCSs), leukotriene receptor antagonists, and nasal decongestants. Nasal GCSs are currently regarded as the most effective treatment and are considered first-line therapy together with non-sedating antihistamines. The new formulation MP29-02 combines the nasal GCS fluticasone propionate with azelastine in one single spray and has achieved greater improvements than those under monotherapy with modern GCSs or antihistamines. Furthermore, this review discusses allergen immunotherapy alone and in combination with modern monoclonal antibodies.
Expert opinion: Despite the variety of medications for allergic rhinitis, ranging from general symptomatic agents like GCSs or decongestants, to more specific ones like histamine receptor or leukotriene blockers, to causal therapy like immunotherapy, many patients still experience treatment failures or unsatisfactory results. The ultimate goal may be to endotype every downstream pathway separately in order to offer patients individualized, targeted therapy with specific antibodies against the respective pathway. 相似文献
Motion is a major confound in diffusion‐weighted imaging (DWI) in the body, and it is a common cause of image artefacts. The effects are particularly severe in cardiac applications, due to the nonrigid cyclical deformation of the myocardium. Spin echo‐based DWI commonly employs gradient moment‐nulling techniques to desensitise the acquisition to velocity and acceleration, ie, nulling gradient moments up to the 2nd order (M2‐nulled). However, current M2‐nulled DWI scans are limited to encode diffusion along a single direction at a time. We propose a method for designing b‐tensors of arbitrary shapes, including planar, spherical, prolate and oblate tensors, while nulling gradient moments up to the 2nd order and beyond. The design strategy comprises initialising the diffusion encoding gradients in two encoding blocks about the refocusing pulse, followed by appropriate scaling and rotation, which further enables nulling undesired effects of concomitant gradients. Proof‐of‐concept assessment of in vivo mean diffusivity (MD) was performed using linear and spherical tensor encoding (LTE and STE, respectively) in the hearts of five healthy volunteers. The results of the M2‐nulled STE showed that (a) the sequence was robust to cardiac motion, and (b) MD was higher than that acquired using standard M2‐nulled LTE, where diffusion‐weighting was applied in three orthogonal directions, which may be attributed to the presence of restricted diffusion and microscopic diffusion anisotropy. Provided adequate signal‐to‐noise ratio, STE could significantly shorten estimation of MD compared with the conventional LTE approach. Importantly, our theoretical analysis and the proposed gradient waveform design may be useful in microstructure imaging beyond diffusion tensor imaging where the effects of motion must be suppressed. 相似文献
Fine‐needle aspiration cytology using a novel ultrasound needle guidance system on the basis of standard needle magnetization was consecutively performed in 30 (15 in‐plane and 15 out‐of‐plane) suspicious thyroid nodules. Nondedicated, commercially available needles were used. The technical effectiveness and safety of the system were satisfying; system failures were observed in 2 cases. The needle tip could be (at least occasionally) visualized inside the thyroid nodule in 96%, and the subjective procedure ratings were excellent in 57%. The out‐of‐plane technique was significantly superior in both respects (P = .021 and .027, respectively). Standard needle magnetization ultrasound needle guidance was easy to apply and cost‐effective and has the potential to improve fine‐needle aspiration cytology performance. 相似文献
Terpenes, especially 3-carene, may irritate the skin and mucous membranes and prolonged exposure may result in allergic contact dermatitis or chronic lung function impairment. The toxicokinetics of 3-carene were studied in human volunteers exposed by inhalation (2 hr 50 W) in an exposure chamber on three occasions. The exposure concentrations were approximately 10, 225, and 450 mg/m3 3-carene. The relative pulmonary uptake was high, approximately 70% for the higher exposure levels. Total uptake increased linearly with increasing exposure. The blood clearance of 3-carene observed in this study, 0.9 liter.kg-1.hr-1, indicates that 3-carene is fairly readily metabolized. About 3% of the total uptake was eliminated unchanged via the lungs while less than 0.001% was eliminated in the urine after the end of exposure. A long half time in blood was observed in the terminal phase which indicates a high affinity to adipose tissues. A statistically significant divergence between ratings of irritation during the high exposure level and during the medium and control levels was observed. The difference in airway resistance after exposure to a high concentration of 3-carene compared to control level was not significant (P = 0.02). 相似文献
OBJECTIVES: Intraoperative cone-beam computerized tomography (CBCT) imaging has been introduced in oral and maxillofacial surgery. Using midfacial fractures as the pioneer model, this study describes the spectrum of further promising clinical indications for intraoperative CBCT and a clinical combination with intraoperative navigation. STUDY DESIGN: One hundred seventy-nine patients admitted for surgical treatment of the facial skeleton were included in the study. Intraoperatively, 3-dimensional images were generated with the mobile CBCT scanner Arcadis Orbic 3D, obtained from Siemens Medical Solutions, in a variety of indications. RESULTS: The acquisition of the data sets was uncomplicated, and image quality was sufficient to assess the postoperative result in all cases. In the example of a facial gunshot injury, a navigation system for intraoperative localization of the metal foreign bodies was used. 相似文献
Rats were exposed to daily 3-hr schedule-induced polydipsia sessions (fixed-time 1-min food-pellet delivery) with two drinking fluids available: cocaine solution and water. Fluid position was alternated daily. Polydipsia occurred mostly from a preferred-side spout (position preference) until cocaine solution concentration was increased to between 0.52 and 1.04 mg/ml and animals drank mostly water. Within a lower concentration range (0.28-0.6 mg/ml) maximum session cocaine intakes ranged from 54.3 to 120.1 mg/kg. Postsession serum cocaine levels were about 200 ng/ml. At individually chosen cocaine solution concentrations, the addition of saccharin to the solution did not increase cocaine intake, but a compound solution (saccharin plus glucose) did. With progressive dilution of the compound vehicle, an almost complete preference for cocaine solution was maintained. But with a return to water as the vehicle, animals reverted to a position preference after a few sessions, although one maintained a clear cocaine preference. Schedule-induced polydipsia produced chronic, oral self-administration of cocaine resulting in pharmacologically significant intakes and serum levels. 相似文献
Glycation (nonenzymatic glucosylation) of collagen may play a role in the primary pathology of the vitreous in diabetes. The extent of glycation is determined by the glucose concentration in the tissue. In this study glucose concentration was assayed in blood and vitreous samples obtained from three patient groups undergoing vitrectomy: nondiabetic patients (ND), diabetic patients with insulin-dependent diabetes mellitus (IDDM) and diabetic patients with non-insulin-dependent diabetes mellitus (NIDDM). In the ND group the glucose concentration in the vitreous (3.5 +- 1.8 mM/1) was always lower than in the blood (9.1 +- 3.5 mM/1). In the diabetic groups the vitreous glucose concentration was, with a few exceptions, generally lower than the blood glucose concentration. The vitreous glucose concentration in these groups was generally higher (IDDM 9.4+-3.3 mM/1, NIDDM 7.2+-3.9 mM/1) than in the ND group, and in 15 specimens exceeded 11 mM/1, a level increasing the probability of collagen glycation in the vitreous of diabetic patients.This study was given financial support by the Herman Järnhardt Foundation, the Inez and Joel Carlsson Foundation and by Diabetesföreningen in Malmö 相似文献