Although classified by the Joint Monitoring Programme (JMP) as unimproved sanitation facilities, public toilets still play a critical role in eliminating open defecation in informal settlements. We explored perspectives of toilet operators on opportunities and barriers to operation and maintenance (O&M) of public toilets in informal settlements. A cross-sectional study design was used. Up to 20 in-depth interviews were used to obtain data on the experiences of public toilet operators. Thematic content analysis was used.
Ressults show that opportunities for improving O&M include; operation of public toilets is a source of livelihood; operators are knowledgeable on occupational risks, and the community is involvedin sanitation activities. Barriers to effective O&M include; high operation costs, failure to break even and a lack of investments in occupational health Therefore, there is need to recognise the significance of public toilets as a viable alternative to open defecation in areas where ownership of private sanitation facilities is difficult. Failure to observe the health and safety of toilet operators may further compromise O&M. 相似文献
PURPOSE: To gather information regarding the global use of simulation technology in education, evaluation and research in anesthesia. METHODS: The WorldWide Web was searched and located sites with simulation centres (n = 158) were mailed a 67-item questionnaire requesting information regarding demographics, personnel, education use and research involvement. Comments were solicited. Medical school data only are reported in this article. RESULTS: Two web sites were used to generate the list of simulation centres. Sixty responses were received (38%), with 41 emanating from medical schools. Seventy-seven percent of centres were involved in undergraduate education and 85% in postgraduate education. Few centres were involved in evaluation and/or competency assessments. Sixty-one percent of centres indicated ongoing research with a further 25% interested in international collaboration. University or university departmental-based funding largely supported simulation technology used in medical schools. The lack of financial and human resources was the single most common problem identified by respondents. CONCLUSIONS: From the survey responses received, opportunities for the simulator to be used for the assessment of performance appear to be under-utilized. This may be due to the lack of research in this area, lack of standardized, valid and reliable tests and the fact that most centres have only recently acquired this technology. Further research supporting the use of the simulator in education and evaluation is required. 相似文献
The anticancer agent temozolomide labeled with 13C (8-Carbamoyl-3-13C-methylimidazo-[5,1-d]-1,2,3,5-tetrazin-4-(3H)-one), was noninvasively detected in subcutaneous RIF-1 tumors by a selective cross polarization 13C NMR method, at a field strength of 9.4T. Pharmacokinetics of the drug, at a dose of 150 mg/kg, were determined for intravenous and intraperitoneal modes of administration (three animals per mode). The half-life of the drug in the tumors was approximately 60 min. The uptake and clearance of the drug, however, varied significantly between individual hosts, for both modes of administration. These results demonstrate the feasibility of obtaining pharmacokinetics of anticancer agents for individual tumors without the need for a label that might modify drug activity (e.g., fluorine). The variability of the in vivo measurements, even within the same tumor model, demonstrates the necessity of directly monitoring the tumor to evaluate drug pharmacokinetics. 相似文献
Fifty patients with suspected intra-abdominal abscess were investigated prospectively with ultrasound and with 99mTc-hexamethylpropylene-amine oxime (HMPAO) isotope labelled mixed leucocytes, using 111-In tropolonate granulocyte scanning as the reference standard. Twenty five patients had inflammatory bowel disease (three were postoperative): 21 of these had Crohn's disease and four had ulcerative colitis. The remainder comprised nine with postoperative fever and 16 with fever and abdominal pain. An abscess was diagnosed when focal activity on serial 111-In tropolonate and 99m-Tc-HMPOA images at one, three, and 24 hours resulted in activity at least equal to liver activity at 24 hours. Thirteen abscesses were diagnosed using each type of white cell scanning, resulting in 100% sensitivity for 99m-Tc-HMPAO compared with 111-In tropolonate. Bowel inflammation was easily distinguished from abscess on serial images. Eight of these 13 abscesses were detected by ultrasound. Altogether 17 abscesses were found. Ultrasound detected 12, including four liver abscesses which were not purulent and had not been detected by white cell scanning. Ultrasound had a sensitivity of 71% (12 of 17) and a specificity of 87% (33 of 38) using all confirmed abscesses as the reference standard. White cell scanning showed a sensitivity of 76% (13 of 17: as a result of the four non-purulent liver abscesses) and a specificity of 100%. 99m-Tc-HMPAO scanning is as accurate as 111-In tropolonate scanning, and has several advantages including simplicity, availability, superior image quality, and reduced radiation dose. Both methods are more sensitive and specific than ultrasound for intra-abdominal abscess detection but ultrasound is advisable if a neutrophil infiltrate is not suspected. 相似文献