首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   35篇
  免费   1篇
临床医学   2篇
内科学   2篇
神经病学   1篇
特种医学   24篇
外科学   6篇
预防医学   1篇
  2022年   1篇
  2019年   1篇
  2016年   1篇
  2010年   1篇
  2009年   1篇
  2007年   1篇
  2006年   2篇
  2005年   2篇
  2004年   6篇
  2003年   4篇
  2002年   5篇
  2001年   4篇
  2000年   1篇
  1999年   3篇
  1998年   1篇
  1992年   1篇
  1991年   1篇
排序方式: 共有36条查询结果,搜索用时 515 毫秒
1.
The aim of this retrospective study was to evaluate the use of digital videofluorography in the preoperative and postoperative management of esophageal achalasia surgical treatment. From 1990 to 2004, 25 patients with achalasia, diagnosed by digital videofluorography and confirmed by motility studies and endoscopy, underwent surgery. All patients underwent digital videofluorography at 1, 6 and 12 months in order to evaluate the completeness of the myotomy and the efficacy of the antireflux procedures. At postoperative videofluorography esophageal transit time was decreased in all patients (100%); esophageal motor activity was unchanged in 23 (92%), and modified in two patients (8%) with onset of peristaltic-like motor activity; 8 patients (35%) presented decreased preoperative dilatation; all patients had a WST negative for post-myotomy reflux. On the basis of our experience and the advantages of the procedure we suggest videofluorography as a first-approach diagnostic examination useful for surgical indications and postoperative follow-up in achalasic patients.  相似文献   
2.
The aim of the study was to report our experience with the use of radiology in functional disorders of the cricopharyngeal muscle and their surgical therapy using digital cineradiology. Five-hundred and seventy dysphagic patients underwent dynamic study of the oral and pharyngeal phases of swallowing (Videofluoroscopic Swallowing Study, VFSS). A motor disorder of the cricopharyngeal muscle was diagnosed by videofluorography in 19 patients: the disorder was mild in 8, moderate in 7 and severe in 4. Two of these underwent cricopharyngeal myotomy, with an improvement in their dysphagia and swallowing mechanisms. VFSS provides a morphological and functional view of the aero-digestive tracts: this is essential in the diagnosis of cricopharyngeal dysfunction and is capable of revealing the related laryngeal penetration and tracheal aspiration. VFSS must always include an oesophageal phase study because of the known clinical and physico-pathological correlations between the gastro-oesophageal junction and the upper oesophageal sphincter. On the basis of our experience we believe that VFSS could be used as a primary investigation, followed by motility studies, and that it may be a useful complementary procedure both in the diagnosis of pharyngo-oesophageal junction motor disorders and with a view to surgical indications.  相似文献   
3.
PURPOSE: To evaluate the current role of small bowel (SB) radiologic barium examinations in adult celiac disease (ACD). MATERIALS AND METHODS: Retrospective review of 61 SB barium examinations in 280 ACD patients. Sixty-one examinations in 61 patients were performed: 7/61 with small bowel 'follow-through' (SBFT) method, and 54/61 with small bowel double-contrast enteroclysis (SBE). Radiological criteria for ACD diagnosis were divided in four groups: 1) definite ACD (reversal of jejuno-ileal fold pattern); 2) possible ACD (malabsorption pattern and ileal jejunization); 3) malabsorption (fluid, dilatation, 'moulage', flocculation); 4) complicated ACD (irregular, thickened, nodular folds; wall thickening; masses). RESULTS: In 49/61 patients RX examinations were performed before ACD diagnosis. In this group, clinical presentations included one or more of the following: diarrhea, weight loss, malabsorption, anemia, abdominal pain; 7/49 had a SBFT, and 42/49 a SBE. All 7 SBFTs showed pattern 3, and 8/42 SBEs showed pattern 2 (suspected ACD). In 34/42 patients SBE allowed a definite ACD diagnosis (pattern 1); however, 6/34 were also false-positive for complicated ACD (pattern 4). Ten out of sixty-one patients were clinically suspected of having complicated ACD, correctly excluded (8/8) or confirmed (2/2) by SBE. None of these 59/61 patients had a radiologic diagnosis of normal' SB. The last 2/61 patients with ACD, examined for persisting chronic anemia, had a normal SBE. CONCLUSIONS: This study confirm that SB radiology may be of value either in ACD diagnosis or in excluding complications: SBE is currently the most accurate examination. SBE alone is however less accurate in confirming complicated ACD; further imaging techniques are always needed in this clinical context.  相似文献   
4.
PURPOSE: The aim of this study was to evaluate the role of digital cineradiography associated with the water siphon test (WST) in the diagnosis of gastroesophageal reflux and to compare the results with oesophageal motility study, pH monitoring and endoscopy associated with biopsy and histology. MATERIALS AND METHODS: One hundred and sixty consecutive patients underwent digital cineradiography with WST, motility study, pH monitoring and endoscopy with biopsy. The presence of gastroesophageal reflux, oesophagitis, Barrett's oesophagus and intestinal metaplasia was evaluated. RESULTS: WST vs. pH monitoring showed sensitivity of 71%, specificity of 31%, positive predictive value (PPV) of 53% and negative predictive value (NPV) of 50%; when middle-proximal refluxes only were considered, sensitivity decreased to 45% and specificity increased to 55%. Furthermore, the association between reflux and oesophagitis demonstrated by the chi-square (chi(2)) test proved to be statistically significant both for WST and pH monitoring, whereas the association between reflux and Barrett's oesophagus was not significant for either WST or for pH monitoring. With regard to intestinal metaplasia, WST (middle-proximal refluxes) showed higher sensitivity (64% vs. 58%) and specificity (63% vs. 51%) than pH monitoring, whereas the statistical association between reflux and metaplasia proved to be significant for WST but not for pH monitoring. CONCLUSIONS: WST is a simple, inexpensive and reliable test that might be useful in the diagnosis of gastroesophageal reflux disease (GERD). A positive WST might be an additional indication for endoscopy with biopsy.  相似文献   
5.
6.
7.
8.
PURPOSE: The obstruction of a bowel segment at both ends results in a closed loop obstruction. Progression to strangulation frequently occurs if surgical intervention is delayed. The role of plain radiography in the diagnosis of closed loop obstruction and strangulation has been shown to be limited, while the recent literature has demonstrated the growing role of computed tomography (CT). This paper reports our experience in the study of closed loop obstruction by CT. MATERIAL AND METHODS: The CT studies of 12 patients with surgically confirmed closed loop obstruction were retrospectively reviewed. The following CT signs were used for the diagnosis: a) fluid-filled distended loops, b) C-shaped incarcerated loop, c) radial distribution of several dilated bowel loops and mesenteric vessels converging toward the point of obstruction, d) triangular or fusiform tapering of the closed loop and/or whirl sign in the site of obstruction. RESULTS: On the basis of these signs, the diagnosis was made in 11 of 12 patients. Only 1 patient, who had a negative CT study, was positive at a subsequent enteroclysis. CT findings of strangulation were associated in 3 cases: slight wall thickening with vascular congestion and mesenteric ascites, confirmed at surgery. DISCUSSION AND CONCLUSIONS: Small bowel obstruction can be distinguished into simple and closed loop obstructions. The latter is a more severe condition which is often complicated by strangulation with vascular impairment, edema and intramural and mesenteric hemorrhage. Consequent arterial insufficiency rapidly leads to ischemia, infarction and necrosis. The radiologist plays a role in the early recognition of the closed loop obstruction and of any sign of strangulation. The role of CT in the diagnosis and workup of patients with suspected intestinal occlusion has been analyzed in the literature with reported 63% sensitivity, 78% specificity and 66% accuracy. CT is also capable of revealing the causes of occlusion in 73-95% of cases. The above CT signs, as confirmed in our experience, allow to identify closed loop obstruction and also small bowel strangulation, thus supplying a valuable contribution to diagnosis and accurate preoperative evaluation. We conclude that CT can accurately demonstrate the presence of closed loop obstruction and can be the technique of choice in patients in whom obstruction is associated with clinical signs suggestive of strangulation.  相似文献   
9.
Rationale, aims and objectives Gastro‐oesophageal reflux disease (GORD) is ‘a condition which develops when the reflux of gastric content causes troublesome symptoms or complications’. Instrumental diagnostic tests generally used for GORD are 24‐hour pH‐metry and upper gastrointestinal (GI) endoscopy but barium study associated with provocative manoeuvres such as the water‐siphon test (WST), has also been used for GORD. The aim of this paper was to estimate the accuracy of several tests in patients with GORD in a tertiary care setting, focusing on WST, which is rapid and non‐invasive, simple to perform and well‐tolerated by patients. Method A total of 172 consecutive patients, symptomatic for reflux referred to a tertiary medical centre, were considered and data regarding the WST, 24‐hour pH‐metry, upper GI endoscopy with histology were analysed using latent class analysis, a multivariable statistical method for estimating the accuracy of tests when a gold standard is not available. Results The overall proportion of GORD in the sample was estimated at 0.664 [95% confidence interval (CI) = (0.589; 0.731)]. WST proved to be the most sensitive [Se = 0.886; 95% CI = (0.688; 1.000)] compared with pH‐metry [Se = 0.620; 95% CI = (0.493; 0.745)] and endoscopy with histology [Se = 0.534; 95% CI = (0.273; 0.789)]. It was less specific [Sp = 0.537; 95% CI = (0.003; 1.000)] than pH‐metry [Sp = 0.547; 95% CI = (0.281; 0.813)], and even less than endoscopy with histology [Sp = 0.862; 95% CI = (0.495; 1.00)]. Positive predictive values were estimated at 0.792 [95% CI = (0.721; 0.862)] for WST, 0.731 [95% CI = (0.643; 0.819)] for pH‐metry and 0.886 [95% CI = (0.811; 0.961)] for endoscopy with histology. Negative predictive values were estimated at 0.707 [95% CI = (0.573; 0.841)] for WST, 0.422 [95% CI = (0.310; 0.534)] for pH‐metry and 0.484 [95% CI = (0.387; 0.581)] for endoscopy with histology. Conclusion Water‐siphon test might possibly be useful in patients with suspected GORD because it is highly sensitive and predictive. A positive outcome of the WST associated with a barium study can certainly justify upper GI endoscopy and support any pharmacological treatment of GORD.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号