We report a case of mediastinal liposarcoma, recurrent after 20 years. A 58-year-old man who presented with dyspnea on exertion was found to have a large mediastinal tumor in chest computed tomography (CT), and he was referred to our hospital. He had undergone an extirpation of a mediastinal liposarcoma about 20 years earlier, and we suspected its recurrence. Because the tumor was very large, it was removed in two stages. Histologically it was diagnosed as a recurrence of the previous well-differentiated liposarcoma. Although liposarcoma is one of the most common soft-tissue sarcomas in adults, a mediastinal liposarcoma is rare. Because the recurrence rate is very high, it is necessary to follow up carefully over a long term. 相似文献
BACKGROUND: Pathological changes in vein grafts begin immediately after arterial circulation is applied to the grafts. Chemical mediator stimulation and mechanical strain induce neointimal hyperplasia and medial thickening of the vein grafts, resulting in their failure. We investigated the inhibitory effect of locally applied cilostazol, an inhibitor of cyclic adenosine monophosphate phosphodiesterase III, on neointimal hyperplasia and medial thickening of the grafts. METHODS AND RESULTS: We established a distal anastomotic stricture model of femoral vein-abdominal aorta interposition grafting in rats. In this model, neointimal hyperplasia was observed not only at the distal anastomotic sites, but also in the graft body at postoperative day 14 and was markedly progressed at day 28. A strong expression of tenascin-C was found in the media and neointima of the graft body. In the grafts around which cilostazol was administered locally using Pluronic gel, neointimal hyperplasia was significantly suppressed compared with control grafts treated with the gel alone, with the mean neointimal cross-sectional area reduced by 87.1% for the graft body and by 78.9% for the distal anastomotic sites and mean medial cross-sectional area of the graft body reduced by 54.2% at day 28 versus the control. Cilostazol treatment decreased cell proliferation and the number of tenascin-C-producing cells seen by in situ hybridization, but the expression of tenascin-C protein was not suppressed. CONCLUSION: We concluded that a single perivascular application of cilostazol inhibits neointimal hyperplasia and medial thickening of vein grafts in a rat model. 相似文献
Since humans are under ceaseless orthostatic stress, the mechanism to maintain arterial pressure (AP) under orthostatic stress against gravitational fluid shift is of great importance. We hypothesized that (1) orthostatic stress resets the arterial baroreflex control of sympathetic nerve activity (SNA) to a higher SNA, and (2) resetting of the arterial baroreflex contributes to preventing postural hypotension. Renal SNA and AP were recorded in eight anaesthetized, vagotomized and aortic-denervated rabbits. Isolated intracarotid sinus pressure (CSP) was increased stepwise from 40 to 160 mmHg with increments of 20 mmHg (60 s for each CSP level) while the animal was placed supine and at 60 deg upright tilt. Upright tilt shifted the CSP–SNA relationship (the baroreflex neural arc) to a higher SNA, shifted the SNA–AP relationship (the baroreflex peripheral arc) to a lower AP, and consequently moved the operating point to marked high SNA while maintaining AP. A simulation study suggests that resetting in the neural arc would double the orthostatic activation of SNA and increase the operating AP in upright tilt by 10 mmHg, compared with the absence of resetting. In addition, upright tilt did not change the CSP–AP relationship (the baroreflex total arc). A simulation study suggests that although a downward shift of the peripheral arc could shift the total arc downward, resetting in the neural arc would compensate this fall and prevent the total arc from shifting downward to a lower AP. In conclusion, upright tilt increases SNA by resetting the baroreflex neural arc. This resetting may compensate for the reduced pressor responses to SNA in the peripheral cardiovascular system and contribute to preventing postural hypotension. 相似文献
BACKGROUND: Myocardial perfusion single photon emission computed tomography (SPECT) occasionally fails to detect coronary stenosis in patients with coronary artery disease (CAD). We evaluated coronary flow reserve (CFR) using oxygen 15-labeled water in areas with and without ischemia on technetium 99m tetrofosmin stress perfusion SPECT in patients with angiographically documented CAD. METHODS AND RESULTS: Twenty-seven patients with CAD and eleven age-matched normal subjects were studied. Baseline myocardial blood flow (MBF) and MBF during hyperemia induced by intravenous adenosine triphosphate infusion (0.16 mg. kg(-1). min(-1)) were determined with the use of O-15-labeled water positron emission tomography, and the CFR was calculated. Tc-99m tetrofosmin stress/rest SPECT was performed for comparison. On the basis of the results of coronary angiography and SPECT, coronary segments were divided into 3 types: segments with coronary stenosis and a perfusion abnormality on stress SPECT imaging (group A, n = 16), segments with coronary stenosis without a perfusion abnormality (group B, n = 42), and remote segments with no coronary stenosis or perfusion abnormality (group C, n = 18). Baseline MBF values were similar among the 3 groups. CFR in group A was lower (1.82 +/- 0.54) than in group B (2.22 +/- 0.87, P <.05), in group C (2.92 +/- 1.21, P <.01), and in normal segments (3.86 +/- 1.24, P <.001). CFR in group B was lower than in group C (P <.02) and in normal segments (P <.001). CFR in group C was lower than in normal segments (P <.02). CONCLUSIONS: Areas with a perfusion abnormality on stress SPECT had reduced CFR. In the areas without a perfusion abnormality and with coronary stenosis, lowering of CFR was intermediate between the areas with a perfusion abnormality and remote segments. Moreover, CFR was slightly, but significantly, lower in remote segments in patients with CAD compared with normal segments. 相似文献
A 52-year-old woman who had had 6 months of chemotherapy using mitomycin C and cisplatin for cervical cancer presented with
hemolytic uremic syndrome. Conventional plasmapheresis using whole-plasma fraction was ineffective. However, plasmapheresis
using the cryosupernatant fraction dramatically improved symptoms of hemolytic anemia and thrombocytopenia in this case. The
activity of factor VIII in the cryosupernatant fraction of plasma as a replacement fluid decreased after removal of cryoprecipitate,
indicating effective removal of von Willebrand factor. The pathogenesis of her hemolytic uremic syndrome may have been associated
with von Willebrand factor multimers contained in the cryoprecipitate of plasma. Similar use of the cryosupernatant fraction
of plasma could not be found in other reports of cases of hemolytic uremic syndrome. Plasmapheresis using the cryosupernatant
fraction of plasma may improve refractory hemolytic uremic syndrome. 相似文献
Summary: In situ hybridization of mRNA for collagen IV, collagen VI, stromelysin (MMP-3) and TIMP1 was examined in renal biopsy specimens from patients with IgA nephropathy (IgAN) or diabetic nephropathy with various degrees of tissue damage. The majority of cells in the glomeruli expressed these mRNA almost simultaneously, but a few cells demonstrated positive expression for only one of these probes. There was a parallel relationship between the degree of tissue damage and that of mRNA expressions of these probes in patients with IgAN, while patients with diabetic nephropathy showed a reverse relationship between these two parameters. It is concluded that patients with mesangial proliferative glomerulonephritis expressed mRNA for collagen collagenase and its inhibitor in the glomeruli in parallel with the progress of tissue damage. In contrast, glomerular samples from patients with diabetic nephropathy showed that there was an inverse relationship between tissue damage and expression of mRNA. It is concluded that expression of collagen, collagenase and its inhibitor parallels the progression of glomerular changes in IgAN, but such parallel expression was not observed in patients with diabetic nephropathy. 相似文献
The present study assessed neuropsychological functions related to attention, executive function and everyday memory in a group of men with a diagnosis of combat-related posttraumatic stress disorder (PTSD). Twenty Bosnian male combat veterans with a diagnosis of PTSD were tested using the Sustained Attention to Response Task, the Hayling Sentence Completion Test, the Trail Making Test, Rivermead Behavioral Memory Test and Wechsler Adult Intelligence Scale (verbal scales). Their performance was compared with age- and IQ-matched male war veterans with no PTSD. The study disclosed pervasive cognitive impairments with large effect sizes pertaining to attention, working memory, executive function, and memory. The effects did not appear to be attributable to alcohol abuse, loss of consciousness, or educational level. We speculate that, in the present group of combat veterans, PTSD was associated with dysfunction of a higher-level attentional resource which in turn affected the activity in other systems concerned with memory and thought. 相似文献
Background. A membrane oxygenator consisting of a microporous polypropylene hollow fiber with a 0.2-μm ultrathin silicone layer (cyclosiloxane) was developed. Animal experimental and preliminary clinical studies evaluated its reliability in bypass procedures.
Methods. Five 24-hour venoarterial bypass periods were conducted on dogs using the oxygenator (group A). In 5 controls, bypass periods were conducted using the same oxygenator without silicone coating (group B). As a preliminary clinical study, 14 patients underwent cardiopulmonary bypass with the silicone-coated oxygenator.
Results. Eight to 16 hours (mean, 12.2 hours) after initiation of bypass, plasma leakage occurred in all group B animals, but none in group A. The O2 and CO2 transfer rates after 24 hours in group A were significantly higher than at termination of bypass in group B (p < 0.005 and p < 0.03, respectively). Scanning electron microscopy of silicone-coated fibers after 24 hours of bypass revealed no damage to the silicone coating of the polypropylene hollow fibers. In the clinical study, the oxygenator showed good gas transfer, acceptable pressure loss, low hemolysis, and good durability.
Conclusions. This oxygenator is more durable and offers greater gas transfer capabilities than the previous generation of oxygenators. 相似文献