BACKGROUND: Computer-assisted image analysis has been proposed for human hair growth studies. METHODS: The performances of Trichoscan, a commercially available automated system combining epiluminiscence microscopy with digital image analysis, developed for office-based hair growth measurements, have been evaluated comparatively on the same skin sites using standardized photographic equipment and calibrated processing for contrast-enhanced phototrichogram (CE-PTG) analysis. This reference method has been validated with scalp biopsies and histological examination of serial sectioning. RESULTS: Besides edge effects, hair fibres escaped the Trichoscan analysis for various reasons including, but not limited to, thickness, pigmentation, closeness and crossing. CONCLUSION: Most of these problems have been identified in the late 1980s and remain largely unsolved by the processing software that was evaluated in 2004. Therefore claims promoting the Trichoscan method for accurate hair measurements in clinical trials on scalp and body hair are not supported by the present investigation. The speed at which the analysis is performed is outweighed by the errors in signal detection. Therefore we suggest that improvements must be clearly documented before Trichoscan is established for quantified diagnostic purposes and detailed hair cycle monitoring during hair trials. 相似文献
Considering that the 1.32-μm Nd-YAG laser should have physicothermal properties close to those of the CO2 laser, a series of experiments were conducted on rat cortex (N = 51). Three laser wavelengths were compared: CO2 laser (10.6 μm), 1.06-μm Nd-YAG, and 1.32-μm Nd-YAG lasers. For each shot, temperature measurements were recorded with an infrared thermographic videocamera. The digitized signals were figured as thermal profiles and temperature developments. Ninety-five shots were correctly studied and analyzed: CO2, N = 29; 1.06-μm Nd-YAG, N = 20; 1.32-μm Nd-YAG, N = 46. The histological lesions produced by these three lasers were compared on animals killed 24 hours (N = 20), 8 days (N = 20), and 30 days (N = 5) after the laser impacts. For equivalent densities of energy, the depth of cortical necrosis was comparable for the CO2 laser (200–250 μm) and the 1.32-μm Nd-YAG laser (210–260μm) whatever the date of death; the 1.06-μm Nd-YAG laser shots were responsible for much more important damage (400–550μm). Because of its important absorption in water and nervous tissue, the authors consider the 1.32-μm Nd-YAG laser most suitable for neurosurgery, particularly because it is conducted through optic fibers, and therefore is easy to handle during neurosurgical procedures. 相似文献
The effects of nedrocromil sodium and disodium cromoglycate were studied on the anaphylactic contraction of guinea-pig trachea in two models of active sensitization (IgE and IgG models). The influence of epithelial removal on the effects of nedocromil sodium and disodium cromoglycate was examined because several studies have shown that the epithelial layer can modulate agonist- or antigen-induced contractile responses. Disodium cromoglycate (10(-4) M) and nedocromil sodium (10(-4) M) provided significant protection against antigen-induced contractions of guinea-pig tracheal smooth muscle in the IgG model. But only nedocromil sodium had an effect at this concentration in the IgG model and was also effective at 10(-5) M in the epithelium-denuded tracheal strips. At this concentration, disodium cromoglycate lost its protective effect. Comparison with the results obtained with FPL-55712, AA-861 and mepyramine suggested that these drugs affect histamine and particularly leukotriene synthesis and/or release by mast cells or other immunocompetent cells. These findings indicate that nedocromil sodium inhibits the IgE- and IgG-related antigen-induced contraction in guinea-pig airways, whereas disodium cromoglycate inhibits only the IgG-related processes. This study supports the hypothesis that these drugs modulate antigen-induced mediator synthesis and/or release from immunocompetent cells. 相似文献
Background: Residual neuromuscular blockade remains a problem even after short surgical procedures. The train-of-four (TOF) ratio at the adductor pollicis required to avoid residual paralysis is now considered to be at least 0.9. The incidence of residual paralysis using this new threshold is not known, especially after a single intubating dose of intermediate-duration nondepolarizing relaxant. Therefore, the aim of the study was to determine the incidence of residual paralysis in the postanesthesia care unit after a single intubating dose of twice the ED95 of a nondepolarizing muscle relaxant with an intermediate duration of action.
Methods: Five hundred twenty-six patients were enrolled. They received a single dose of vecuronium, rocuronium, or atracurium to facilitate tracheal intubation and received no more relaxant thereafter. Neuromuscular blockade was not reversed at the end of the procedure. On arrival in the postanesthesia care unit, the TOF ratio was measured at the adductor pollicis, using acceleromyography. Head lift, tongue depressor test, and manual assessment of TOF and DBS fade were also performed. The time delay between the injection of muscle relaxant and quantitative measurement of neuromuscular blockade was calculated from computerized anesthetic records.
Results: The TOF ratios less than 0.7 and 0.9 were observed in 16% and 45% of the patients, respectively. Two hundred thirty-nine patients were tested 2 h or more after the administration of the muscle relaxant. Ten percent of these patients had a TOF ratio less than 0.7, and 37% had a TOF ratio less than 0.9. Clinical tests (head lift and tongue depressor) and manual assessment of fade showed a poor sensitivity (11-14%) to detect residual blockade (TOF < 0.9). 相似文献
Five hundred and thirty-three women attending a genitourinary medicine clinic underwent concurrent cytology and Chlamydia trachomatis screening using a Cytobrush (Medscand AB). In each case, the same Cytobrush was used to give a sample for direct immunofluorescence and culture. 11.1% of samples were positive by immunofluorescence, while 10.6% were positive by culture. This was a close agreement (Kappa = 0.875). The ability of the same instrument to be used for both cytology and chlamydial screening, where direct immunofluorescence is used for detection of chlamydiae, may allow more widespread screening for chlamydia to be practical. 相似文献