首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   0篇
临床医学   2篇
内科学   7篇
特种医学   1篇
外科学   2篇
综合类   1篇
预防医学   1篇
  2021年   3篇
  2015年   2篇
  2012年   1篇
  2010年   1篇
  2004年   1篇
  2003年   2篇
  2002年   1篇
  2001年   1篇
  1997年   1篇
  1996年   1篇
排序方式: 共有14条查询结果,搜索用时 15 毫秒
1.
The International Journal of Cardiovascular Imaging - Abnormal atrial mechanics in biventricular circulations have been associated with elevated left heart filling pressures. Similar associations...  相似文献   
2.
3.
We report a 12-year-old girl who had multiple congenital cardiac lesions, specifically an arterial duct, left pulmonary arterial stenosis, an atrial septal defect in the oval fossa, and mild Ebstein's malformation of the tricuspid valve. Therapeutic transcatheter intervention was performed to stent the left pulmonary artery, occlude the arterial duct with a coil, and place a device to close the atrial septal defect. Subsequent to the catheterization, she complained of hoarseness, which was shown to be due to entrapment of the left recurrent laryngeal nerve between the coil used to close the arterial duct and the stent placed in the left pulmonary artery. Laryngoscopy confirmed paralysis of the recurrent laryngeal nerve.  相似文献   
4.
Abstract   Objectives: We report results of left atrioventricular valve reoperations (LAVVR) following atrioventricular septal defect (AVSD) repair and examine variables predictive of outcome. Methods: Multiple demographics and operative variables were analyzed to determine factors affecting survival and reoperation. Results: Forty patients following partial (n = 9) or complete (n = 31) AVSD repair underwent 47 LAVVR (1992-2005). Median age was 0.87 years (24 days-7.7 years) at initial AVSD repair and 3.15 years (84 days-13.6 years) at subsequent LAVVR with median interval between AVSD repair and LAVVR of 1.76 years (1 day-12.9 years). First LAVVR included repair (n = 20) or replacement (n = 20). Operative mortality was 10% and five-year survival was 76 ± 6%. Significant risk factors were complete AVSD (p < 0.001), valve replacement (p < 0.001) for early death, and young age at time of LAVVR (p = 0.03) for late death. Five-year freedom from LAVV re-intervention was 100% for replacement versus 55 ± 13% for repair (p = 0.006). Overall, ejection fraction increased to 61 ± 3% versus 42 ± 2% preoperatively (p < 0.01), and left-ventricle end-diastolic dimension Z-score decreased to 0.05 ± 0.36 versus 3.1 ± 0.3 preoperatively (p < 0.01). Eighty-seven percent of children were in New York Heart Association class I/II at latest follow-up. Conclusions: LAVVR results in significant clinical improvement and lasting recovery in ventricular chamber function and size. Valve repair offers survival advantage and should be aggressively attempted; however, it is only achievable in 50% of cases. Valve replacement is necessary in cases associated with complex LAVV morphology or following repair failure. At intermediate follow-up, patients continue to be at risk of major valve-related morbidity, requirement for re-intervention, and cardiac death. (J Card Surg 2010;25:74-78)  相似文献   
5.
We describe the clinical history of a nine years old girl with Shone's syndrome. She underwent balloon angioplasty of the aortic coarctation in infancy, and later developed severe sub-aortic stenosis and moderate mitral valvar stenosis. The mitral valve was therefore replaced with a mechanical prosthesis, and the sub-aortic shelf was resected. Immediately after the operation, she developed signs of myocardial ischemia. Coronary angiography showed compression of the middle part of the circumflex artery by the mechanical prosthesis, the obstructed segment being successfully dilated using a coronary arterial stent.  相似文献   
6.
We report a unique case of left ventricular noncompaction (LVNC), tetralogy of Fallot, and multiples biventricular thrombi in a Down''s syndrome. Of interest, speckle tracking analysis detected an abnormal LV myocardial longitudinal deformation, despite the normal ejection fraction and absence of NC at the baseline evaluation.  相似文献   
7.
IntroductionRadiologists and radiographers play a complementary role in providing an optimal image quality with decrease radiation dose and proper diagnosis during chest radiographs. We aim Investigate years of experience among radiologists and radiographers on perception of image quality and its impact on repeat rate when evaluating portable pediatric chest radiographs.MethodsIRB approved retrospective study consisted of randomly selected images (n = 131) of pediatric portable chest radiographs. Images were blindly assessed by four radiologists and four radiographers. Readers were asked to assess qualitative and quantitative image quality by rating: image quality, decision to repeat and image technique. All data was compared employing Pearson's Correlation, Visual grading characteristic (VGC) and Cohens' kappa analyses.ResultsImage quality: Radiologists (88.4%) rated images as excellent significantly more than radiographers (11.6%), and radiographers (90.1%) as poor significantly more than radiologists (9.9%) (p < 0.05). Repeat: Radiologists (57%) decided not to repeat images significantly more than radiographers (43%) (p < 0.05). Image technique: Radiologists rated images as acceptable (65%) and excellent (97.7%) significantly more than radiographers (35% and 2.3% respectively) (p < 0.05), whereas radiographers (84%) assessed image technique as poor significantly more than radiologists (16%) (p < 0.05). VGC: radiographers had slightly better qualitative evaluation of image quality than radiologists. An association between image quality (p < 0.002) and repeat decision (p < 0.044) with years of experience was established when comparing years of experience with image assessment rubric, while no association was noted with image technique (p < 0.9).ConclusionRadiologists demonstrated more decisiveness than their fellow radiographers in reducing the repeat rate of portable pediatric chest radiographs. Interestingly, years of experience only seem to affect image technique and image quality assessment among radiologists.Implications for practiceContinuous education of radiographers and close collaboration with radiologists is crucial to achieve optimal image quality and low radiation doses.  相似文献   
8.
This report describes a 1-day-old infant with valvar pulmonary atresia with intact ventricular septum in whom we were successful in performing transcatheter guidewire perforation and balloon pulmonary valvuloplasty to establish right ventricle-to-pulmonary artery continuity and flow. Also described is implantation of a 4 mm coronary stent into ductus arteriosus in lieu of surgical aortopulmonary shunt to treat pulmonary oligemia and systemic arterial hypoxemia. Details of transcatheter guidewire perforation are presented and it is suggested that this method be used as an alternative to Laser/radio frequency wires, especially in the absence of approval of the latter wires by the regulatory agencies. Stenting of the ductus may be considered an alternative to surgical aortopulmonary shunt. Role of transcatheter technology in the management of selected patients with pulmonary atresia and intact ventricular septum is discussed. Cathet. Cardiovasc. Diagn. 42:395–402, 1997. © 1997 Wiley-Liss, Inc.  相似文献   
9.
Journal of Public Health - This study aimed to explore the knowledge, attitude, and practice that community pharmacists of Lebanon hold with regard to checking for drug interactions. This...  相似文献   
10.

Aims:

Three-dimensional speckle-tracking echocardiography (3D-STE) is a promising new technique to evaluate left ventricular (LV) mechanics. The feasibility and normal values of LV strain using 3D-STE have recently been established in adults and children. Unfortunately, no data are available in neonates. The aims of this study were to evaluate the feasibility and establish normal values of 3D LV volumes, ejection fraction (EF), and the 4 normal strains in healthy neonates.

Materials and Methods:

Of 50 consecutive newborns who were delivered at our hospital or returned to their first newborn follow-up within the first 3 weeks of life, 38 babies underwent full echocardiographic evaluation, including the acquisition of at least 3 full volume data sets from the apical window, while naturally sleeping. Data sets were analyzed offline. Global LV longitudinal, circumferential, and radial strain, as well as 3D LV volumes and EF, were measured using 3D-STE.

Results:

Of the 50 newborns, 2 patients were excluded because of significant intra-cardiac shunts, and in another 10 subjects, parents did not give consent. At least one data set was adequate for analysis in all the remaining subjects. Mean indexed LV diastolic, systolic volumes, and EF were 24.7 ± 3.6 ml/m2, 9.2 ± 1.3 ml/m2, and 63% ± 3.7%, respectively. Normal global longitudinal, circumferential, radial, and tangential 4D strain were −20.9% ± 2.8%, −32.4% ± 3.1%, 44.3% ± 3.4%, and −39.7% ± 3.4%, respectively.

Conclusions:

3D-STE is feasible in newborns without the needed for sedation. Reference values of normal, regional, and global LV 4D strain and volumes were obtained.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号