首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   1篇
临床医学   3篇
内科学   2篇
皮肤病学   1篇
药学   1篇
  2016年   1篇
  2012年   1篇
  2003年   1篇
  2001年   1篇
  1994年   1篇
  1988年   1篇
  1986年   1篇
排序方式: 共有7条查询结果,搜索用时 31 毫秒
1
1.
Several analogues of N3-fumaramoyl-L-2,3-diaminopropanoic acid were synthesized and evaluated for inhibition of glucosamine-6-phosphate synthetase activity. The syntheses were accomplished by acylation reaction of N2-tert.-butoxycarbonyl-L-2,3-diaminopropanoic acid (Boc-A2pr) or N2-tert.-butoxy-carbonyl-L-2,4-diaminobutanoic acid (Boc-A2-bu) with the N-succinimidoyl esters of several derivatives of α, β-unsaturated acids 2a-d followed by deprotection of the Boc groups. The obtained compounds were tested for inhibition of glucosamine synthetase isolated from Salmonella typhimurium and Saccharomyces cerevisiae. The results indicated that among the synthesized compounds, N3-4-methoxyfumaroyl-L-2,3-diaminopropanoic acid (FMDP) was the most powerful inhibitor of glucosamine synthetase.  相似文献   
2.
Ventricular Oversensing:   总被引:8,自引:1,他引:7  
WERETKA, S., et al. : Ventricular Oversensing: A Study of 101 Patients Implanted with Dual Chamber Defibrillators and Two Different Lead Systems . Modern dual chamber ICD systems are able to overcome various sensing problems. However, improvement of their performance is still required. The aim of this study was to assess the sensing function in 101 consecutive patients (84 men, 17 women; mean age 63 ± 12 years; mean follow-up 24 ± 4 months) implanted with dual chamber defibrillators and integrated (IB) or dedicated bipolar (DB) lead systems. Follow-up data were analyzed for the presence of ventricular oversensing. Oversensing occurred in 25 (25%) patients, significantly more frequent in patients implanted with IB compared to DB lead systems (21/52 vs 4/49, P = 0.0002). Patients with cardiomyopathies (CMs) were more prone to sensing malfunctions than patients with no CM (12/30 vs 13/71, P = 0.04). T wave oversensing (n = 14), respirophasic ventricular oversensing (n = 4), and P wave oversensing (n = 6) were the most common pitfalls of ventricular sensing. P wave oversensing was unique to the IB lead system. CT scans performed in these patients disclosed the position of the RV coil to be proximal to the tricuspid area. Four patients received inappropriate ICD shocks due to oversensing. In all but two patients who received lead revision, oversensing was resolved by noninvasive means. In conclusion: (1) ventricular oversensing is a common problem occurring in up to 25% of patients with dual chamber ICDs; (2) P wave oversensing is a ventricular sensing problem affecting function of 11% of dual chamber devices with IB lead systems; (3) IB leads are significantly more susceptible to T wave and P wave oversensing than DB leads; and (4) patients with cardiomyopathies are more prone to oversensing than patients with other heart diseases. (PACE 2003; 26[Pt. I]:65–70)  相似文献   
3.
WERETKA, S., et al. : Far-Field R Wave Oversensing in a Dual Chamber Arrhythmia Management Device: Predisposing Factors and Practical Implications. Initial experience with the Medtronic Jewel 7250, the ICD designed to detect and treat ventricular and supraventricular tachyarrhythmias, is very promising. Its effectiveness, however, depends on sensing performance, which has not yet been systematically examined. The aim of the study was to determine the incidence of, predisposing factors for, and practical implications of far-field R wave oversensing (FFRWOS) in this dual chamber ICD. During a total follow-up of 797 months in 48 patients who had the Jewel 7250, follow-up strip charts, 12-channel Holter recordings and, in particular cases, Holter recordings with intracardiac markers were analyzed for the presence of FFRWOS. FFRWOS was documented in ten (21.3%) patients. Compared to other lead locations, the right atrial appendage lead position was most frequently associated with FFRWOS (  7/27 vs 3/21, P < 0.05  ). Patients with FFRWOS had significantly more treated and nontreated atrial episodes, many of which were judged to have been detected inappropriately. In one case, inappropriate atrial antitachycardia pacing due to R wave oversensing triggered sustained ventricular tachycardia, terminated eventually with a high energy shock. In dual chamber ICDs, FFRWOS may represent a frequent phenomenon possibly leading to serious consequences. For atrial leads, a lateral atrial wall position seems to be preferable. In most cases, FFRWOS can be eliminated by optimization of atrial sensing parameters. Given the possibility of ventricular proarrhythmia with atrial pacing therapy, the capability of ventricular backup defibrillation in respective devices is at least reassuring.  相似文献   
4.
5.
Cardiac implantable electronic devices (CIEDs) have been in use for over 50 years and their therapeutic value is undisputable. With the rapidly aging population, it is estimated that the number of CIEDs will grow dramatically over the next 2 decades. Given these predictions, the topic of management of concomitant conditions associated with older age becomes more relevant than ever. In particular, the number of patients with an implanted CIED diagnosed with cancer is expected to rise by about 70%, from 14 million in 2012 to 22 million within the next 2 decades. Treatment of most of these tumors and tumor metastases requires radiation therapy. However, the necessary high doses of radiation can potentially interact with the function, longevity, and integrity of the CIEDs and/or cause harm to the patient. The impact of an absence of clear therapeutic guidelines for oncology patients with CIEDs who should undergo radiation therapy is vast; and due to the fear of possible complications related to device failure, many of these patients may not be treated adequately to their needs, which can strongly affect their prognosis. This article summarizes the available data on the management of patients with CIEDs undergoing radiotherapy. It systematically presents possible causes and consequences of direct and scattered radiation on CIEDs, highlights possible complications that may occur during this kind of treatment, and provides practical guidance for this challenging real life clinical setting.  相似文献   
6.
Background. The basic phenomenon in psoriasis appears to be a directed leukocyte migration that in a great part, depends on the cell-extracellular matrix (ECM) interactions. Methods. To evaluate the leukocyte-ECM interactions in psoriasis, we investigated the adherence of peripheral blood mononuclear cells (PBMC) and polymorphonuclear leukocytes (PMNL) to ECM components (collagen type I, IV, laminin, and fibronectin), using crystal violet staining and measuring absorbance at 570 nm. Results. In the most active cases of psoriasis (pin-point and guttate type) of short duration, we found a decreased adherence of PBMC to collagen type IV. In a majority of cases of actively spreading plaque psoriasis of large extent and longer duration, there was decreased adherence to all ECM components, especially to collagen type IV and laminin. The adhesion of PMNL to collagen type IV (but not to other ECM components) was increased only in cases of short duration. Preliminary data suggest that etretinate treatment may modulate leukocyte adherence to the ECM components in patients with psoriasis. Conclusions. The decreased in vitro adherence of PBMC to ECM components, especially those of the basement membrane, may reflect their in vivo activation and migration to the epidermis, which is a basic phenomenon in psoriasis that could be affected by etretinate therapy.  相似文献   
7.
Summary. Aims: Blood cell infiltration and inflammation are involved in atrial remodelling during atrial fibrillation (AF) although the exact mechanisms of inflammatory cell recruitment remain poorly understood. Platelet‐bound stromal cell‐derived factor‐1 (SDF‐1) is increased in cases of ischemic myocardium and regulates recruitment of CXCR4+ cells on the vascular wall. Whether platelet‐bound SDF‐1 expression is differentially influenced by non‐valvular paroxysmal or permanent atrial fibrillation (AF) in patients with stable angina pectoris (SAP) or acute coronary syndrome (ACS) has not been reported so far. Methods and results: A total of 1291 consecutive patients with coronary artery disease (CAD) undergoing coronary angiography were recruited. Among the patients with SAP, platelet‐bound‐SDF‐1 is increased in patients with paroxysmal AF compared with SR or to persistent/permanent AF (P < 0.05 for both). Platelet‐bound SDF‐1 correlated with plasma SDF‐1 (r = 0.488, P = 0.013) in patients with AF and ACS, which was more pronounced among patients with persistent AF (r = 0.842, P = 0.009). Plasma SDF‐1 was increased in persistent/permanent AF compared with SR. Patients with ACS presented with enhanced platelet‐bound‐SDF‐1 compared with SAP. Interestingly, among patients with ACS, patients with paroxysmal or persistent/permanent AF presented with an impaired platelet‐bound SDF‐1 expression compared with patients with SR. Conclusions: Differential expression of platelet‐bound and plasma SDF‐1 was observed in patients with AF compared with SR which may be involved in progenitor cell mobilization and inflammatory cell recruitment in patients with AF and ischemic heart disease. Further in vivo studies are required to elucidate the role of SDF‐1 in atrial remodeling and the atrial fibrillation course.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号