首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   21篇
  免费   1篇
儿科学   1篇
妇产科学   1篇
基础医学   2篇
临床医学   7篇
内科学   2篇
皮肤病学   1篇
特种医学   3篇
外科学   1篇
预防医学   2篇
肿瘤学   2篇
  2006年   2篇
  2005年   1篇
  1998年   1篇
  1996年   3篇
  1995年   1篇
  1994年   3篇
  1993年   2篇
  1992年   1篇
  1988年   1篇
  1986年   1篇
  1959年   1篇
  1958年   1篇
  1957年   1篇
  1956年   1篇
  1954年   2篇
排序方式: 共有22条查询结果,搜索用时 31 毫秒
1.
Premature pulmonary valve opening has been described in various conditions associated with increased right ventricular end-diastolic pressure. Although cardiac amyloidosis belongs to this category of diseases, abnormalities of pulmonary valve motion have not been reported in this setting. This article describes premature pulmonary valve opening in a patient with cardiac amyloidosis.  相似文献   
2.
Sixteen patients with Medtronic 4003 steroid-eluting electrodes implanted in the ventricular position were followed over 5 years. In each patient a special type of Medtronic 2443 pacemaker was implanted to allow programming of output at 1.35 V. Chronic threshold values in these patients measured at an output of 1,35 V were stable over the first 18 months of follow-up. Mean values were: 0.06 ± 0.03 msec at 6 months and 0.08 ± 0.02 msec at 18 months; these did not differ from each other significantly. However, during the period from 18 to 36 months postimplantation, a significant increase in mean pacing threshold was observed: 0.08 ± 0.02 msec at 18 months postimplantation versus 0.14 ± 0.05 msec at 36 months (P < 0.01), After 36 months, the chronic pacing threshold remained stable until the end of the 5-year follow-up period. Further long-term study of chronic threshold behavior of steroid-eluting electrodes measured at low amplitudes is warranted.  相似文献   
3.
4.
5.
AIM: To present the results from one clinic's experience of using small intestinal submucosa (SIS) in augmentation urethroplasty for management of strictures of the bulbar urethra. METHODS: Urethral surgery was performed in nine men with strictures 4-6 cm. All of the patients were evaluated by history, physical examination, retrograde urethrogram, and uroflowmetry. Four layers of SIS were soaked in saline or Ringer's solution for 15 minutes at 37 degrees C, and the inner surface of the patch was gently fenestrated with a thin scalpel. The patch was spread-fixed onto the tunica albuginea. The mucosa was sutured to the submucosal graft first at 2-3 mm inwards from the SIS margins, then the spongiosum tissue was attached to the margins with interrupted absorbable sutures. RESULTS: Of the nine patients who underwent augmentation urethroplasty using SIS, only one had re-stricture at 6 months due to urethral infection. At 18 months after the surgery the uroflowmetry of the other eight patients was 20-21 mL/s. In terms of complications, six patients reported having post-micturition dribbling, and seven patients reported lack of morning erections for 35-69 days after surgery. CONCLUSIONS: Using SIS is a safe procedure; however, long-term follow-up is needed to substantiate the good short-term results.  相似文献   
6.
DNA-dependent protein kinase (DNA-PK) consists of a DNA binding subunit (Ku autoantigen), and a catalytic subunit (DNA-PKcs). In the present study, human autoantibodies that recognize novel antigenic determinants of DNA-PK were identified. One type of autoantibody stabilized the interaction of DNA-PKcs with Ku and recognized the DNA-PKcs–Ku complex, but not biochemically purified DNA-PKcs. Another type recognized purified DNA-PKcs. Autoantibodies to Ku (p70/p80 heterodimer), ‘stabilizing’ antibodies, and antibodies to DNA-PKcs comprise a linked autoantibody set, since antibodies recognizing purified DNA-PKcs were strongly associated with stabilizing antibodies, whereas stabilizing antibodies were strongly associated with anti-Ku. This hierarchical pattern of autoantibodies specific for components of DNA-PK (anti-Ku>stabilizing antibodies>anti-DNA-PKcs) may have implications for the pathogenesis of autoimmunity to DNA-PK and other chromatin particles. The data raise the possibility that altered antigen processing and/or stabilization of the DNA-PKcs–Ku complex due to autoantibody binding could play a role in spreading autoimmunity from Ku to the weakly associated antigen DNA-PKcs.  相似文献   
7.
8.
The effect of right ventricular pacing on left ventricular relaxation was studied in 13 patients (age 62 ± 3 years), with the atrial sensing ventricular pacing mode (VDD). A control group of similar age (64 ± 4 years) consisted of 11 patients with atrial pacing (AAI). The timing of events was determined in both groups at similar R-R intervals (921 ± 77 ms vs 967 ± 37 ms). The loading conditions as estimated by peak systolic wall stress (afterload) and end-diastolic left ventricular dimensions (preload) were approximately the same in both groups. The ratio of late to early filling velocities were similar in both groups. Dominant changes were: increased preejection period (142 ± 13 ms vs 95 ± 15 ms); and higher velocities of isovolumic relaxation flow (60 ± 34 cm/s vs 25 ± 4 cm/s) in patients with ventricular pacing. The isovolumic relaxation time was longer in patients with VDD pacing (127 ± 14 ms vs 108 ± 12 ms). Anterior systolic interventricular septal motion (paradoxal motion) was recorded in nine patients with VDD pacing and in none of the patients with AAI pacing. Isovolumic relaxation flow was detected during atrial pacing in five (45%) patients and in 13 (100%) patients during atrial sensing ventricular pacing, indicating asynchronous left ventricular relaxation. This data shows that VDD pacing compared to atrial pacing resulted in an altered activation pattern of the left ventricle, associated with delayed onset, asynchronous contraction with interventricular septal motion abnormalities and prolonged asynchronous left ventricular relaxation with abnormal motion manifested by the presence of isovolumic relaxation flow.  相似文献   
9.
Endocardial pacing system implantation has been performed in 15 children of mean age 37 months (ranging from 1 day to 89 months), Endocardial lead fixation was performed by means of slowly resorbable suture (Dexon) to allow spontaneous lead migration as the child grows. During a mean follow-up period of 61 months (range 17–108 months), none of the patients needed reintervention for correcting the lead length to allow growth.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号