排序方式: 共有35条查询结果,搜索用时 15 毫秒
1.
A Decrease in Pulmonary Vein Diameter After Radiofrequency Ablation Predicts the Development of Severe Stenosis 总被引:3,自引:0,他引:3
ALEXANDER BERKOWITSCH THOMAS NEUMANN OKAN EKINCI HARALD GREISS THORSTEN DILL KLAUS KURZIDIM MALTE KUNISS HANS J. SCHNEIDER HEINZ F. PITSCHNER 《Pacing and clinical electrophysiology : PACE》2005,28(S1):S83-S85
A decrease in ostial pulmonary vein (PV) diameter was observed in patients on the day after radiofrequency ablation of atrial fibrillation (AF). This study examined whether a relative reduction in PV diameter on day 1 (RRPVD1) after the procedure predicts the late development of severe PV stenosis (PVS). The study included 104 consecutive patients (mean age = 55 years, range 46–61, 34 women) with drug refractory AF. Pulmonary vein diameter was measured using MR angiography (MRA) on the day before and on day 1 after the ablation procedure. The MRA was repeated every 3 months after the procedure. Severe PVS was defined as a >70% diameter reduction from the initial ostial diameter. The cut-off of RRPVD1 was prespecified as 25% decrease in initial diameter. The data are presented as medians and interquartile range. A total of 357 PV were treated. The RRPVD1 was 0.0% (0.0–11.1%). Severe PVS was found in 18 PV during a follow-up of 12 months (range 6–13). The log-rank analysis confirmed a strong association between a RRPVD1 ≥25% and the development of PVS (hazard ratio: 7.1; 95% confidence interval 3.8–13.5, P < 0.0001). By multivariate Cox regression model, after adjustment of procedure variables, RRPVD1 was the strongest predictor of development of severe PVS. RRPVD1 ≥25% was a strong independent predictor of development of severe PVS. 相似文献
2.
WERNER PETERS PETER KOWALLIK KARIN WILHELM MALTE MEESMANN 《Pacing and clinical electrophysiology : PACE》1996,19(11):1918-1922
It has been demonstrated that successful thrombolytic therapy is associated with a reduction of late potentials in the signal-averaged electrocardiogram (SAECG) recorded within 48 hours after hospital admission. This study extends these observations, using for the first time a longitudinal design investigating whether ischemia and its potential reversal by thrombolytic therapy are associated with dynamic changes in SAECG recordings obtained continuously for 8 hours after the start of therapy in patients with acute myocardial infarction (MI). SAECGs were obtained from 12 patients (2 women and 10 men; ages 63 ± 13 years) with acute MI. The SAECG (X2 + Y2 + Z2 )1/2 was generated with a high pass filter of 40 Hz, noise ≤ 0.3 μV. Comparing the SAECG recordings during the first and eighth hours, there was a significant decrease in filtered QRS duration (fQRS; 119.5 ± 17.1 vs 106.3 ± 15.3 ms) and duration of the low amplitude signals ≤ 40 μV of the terminal QRS (LAS40; 48.8 ± 18 vs 34.2 ± 14.2 ms), and increase of root mean square voltage of the last 40 ms of the QRS (t-RMS; 14.8 ± 9.3 vs 37.8 ± 34.4 μV) (rank test, P ≤ 0.05). In this patient series, there was a significant improvement of fQRS, t-RMS, and LAS40 during the first 8 hours of acute MI, perhaps indicating reversal of ischemia with thrombolysis. Even during acute MI, these markers of delayed conduction allow investigation of intervention induced changes in myocardial conduction and possibly prediction of the patency of the infarct related artery using signal-averaging techniques. 相似文献
3.
Ventricular Oversensing: 总被引:8,自引:1,他引:7
SLAWOMIR WERETKA JOCHEN MICHAELSEN RUEDIGER BECKER CHRISTOPH A. KARLE FREDERIK VOSS THOMAS HILBEL BRIGITTE R. OSSWALD† MALTE L. BAHNER‡ JULIA C. SENGES WOLFGANG KUEBLER WOLFGANG SCHOELS 《Pacing and clinical electrophysiology : PACE》2003,26(1P1):65-70
WERETKA, S., et al. : Ventricular Oversensing: A Study of 101 Patients Implanted with Dual Chamber Defibrillators and Two Different Lead Systems . Modern dual chamber ICD systems are able to overcome various sensing problems. However, improvement of their performance is still required. The aim of this study was to assess the sensing function in 101 consecutive patients (84 men, 17 women; mean age 63 ± 12 years; mean follow-up 24 ± 4 months) implanted with dual chamber defibrillators and integrated (IB) or dedicated bipolar (DB) lead systems. Follow-up data were analyzed for the presence of ventricular oversensing. Oversensing occurred in 25 (25%) patients, significantly more frequent in patients implanted with IB compared to DB lead systems (21/52 vs 4/49, P = 0.0002). Patients with cardiomyopathies (CMs) were more prone to sensing malfunctions than patients with no CM (12/30 vs 13/71, P = 0.04). T wave oversensing (n = 14), respirophasic ventricular oversensing (n = 4), and P wave oversensing (n = 6) were the most common pitfalls of ventricular sensing. P wave oversensing was unique to the IB lead system. CT scans performed in these patients disclosed the position of the RV coil to be proximal to the tricuspid area. Four patients received inappropriate ICD shocks due to oversensing. In all but two patients who received lead revision, oversensing was resolved by noninvasive means. In conclusion: (1) ventricular oversensing is a common problem occurring in up to 25% of patients with dual chamber ICDs; (2) P wave oversensing is a ventricular sensing problem affecting function of 11% of dual chamber devices with IB lead systems; (3) IB leads are significantly more susceptible to T wave and P wave oversensing than DB leads; and (4) patients with cardiomyopathies are more prone to oversensing than patients with other heart diseases. (PACE 2003; 26[Pt. I]:65–70) 相似文献
4.
5.
6.
MEESMANN A 《Medizinische Klinik》1956,51(28):1184-1186
7.
8.
MEESMANN A 《Medizinische Klinik》1956,51(27):1146-1148
9.