首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   2篇
临床医学   21篇
内科学   11篇
皮肤病学   1篇
外科学   1篇
眼科学   1篇
  2015年   2篇
  2014年   2篇
  2010年   4篇
  2009年   3篇
  2005年   1篇
  2003年   1篇
  2001年   1篇
  1998年   2篇
  1997年   1篇
  1996年   1篇
  1995年   2篇
  1992年   1篇
  1985年   1篇
  1958年   1篇
  1957年   1篇
  1956年   6篇
  1955年   3篇
  1954年   1篇
  1953年   1篇
排序方式: 共有35条查询结果,搜索用时 15 毫秒
1.
A decrease in ostial pulmonary vein (PV) diameter was observed in patients on the day after radiofrequency ablation of atrial fibrillation (AF). This study examined whether a relative reduction in PV diameter on day 1 (RRPVD1) after the procedure predicts the late development of severe PV stenosis (PVS). The study included 104 consecutive patients (mean age = 55 years, range 46–61, 34 women) with drug refractory AF. Pulmonary vein diameter was measured using MR angiography (MRA) on the day before and on day 1 after the ablation procedure. The MRA was repeated every 3 months after the procedure. Severe PVS was defined as a >70% diameter reduction from the initial ostial diameter. The cut-off of RRPVD1 was prespecified as 25% decrease in initial diameter. The data are presented as medians and interquartile range. A total of 357 PV were treated. The RRPVD1 was 0.0% (0.0–11.1%). Severe PVS was found in 18 PV during a follow-up of 12 months (range 6–13). The log-rank analysis confirmed a strong association between a RRPVD1 ≥25% and the development of PVS (hazard ratio: 7.1; 95% confidence interval 3.8–13.5, P < 0.0001). By multivariate Cox regression model, after adjustment of procedure variables, RRPVD1 was the strongest predictor of development of severe PVS. RRPVD1 ≥25% was a strong independent predictor of development of severe PVS.  相似文献   
2.
It has been demonstrated that successful thrombolytic therapy is associated with a reduction of late potentials in the signal-averaged electrocardiogram (SAECG) recorded within 48 hours after hospital admission. This study extends these observations, using for the first time a longitudinal design investigating whether ischemia and its potential reversal by thrombolytic therapy are associated with dynamic changes in SAECG recordings obtained continuously for 8 hours after the start of therapy in patients with acute myocardial infarction (MI). SAECGs were obtained from 12 patients (2 women and 10 men; ages 63 ± 13 years) with acute MI. The SAECG (X2+ Y2+ Z2)1/2 was generated with a high pass filter of 40 Hz, noise ≤ 0.3 μV. Comparing the SAECG recordings during the first and eighth hours, there was a significant decrease in filtered QRS duration (fQRS; 119.5 ± 17.1 vs 106.3 ± 15.3 ms) and duration of the low amplitude signals ≤ 40 μV of the terminal QRS (LAS40; 48.8 ± 18 vs 34.2 ± 14.2 ms), and increase of root mean square voltage of the last 40 ms of the QRS (t-RMS; 14.8 ± 9.3 vs 37.8 ± 34.4 μV) (rank test, P ≤ 0.05). In this patient series, there was a significant improvement of fQRS, t-RMS, and LAS40 during the first 8 hours of acute MI, perhaps indicating reversal of ischemia with thrombolysis. Even during acute MI, these markers of delayed conduction allow investigation of intervention induced changes in myocardial conduction and possibly prediction of the patency of the infarct related artery using signal-averaging techniques.  相似文献   
3.
Ventricular Oversensing:   总被引:8,自引:1,他引:7  
WERETKA, S., et al. : Ventricular Oversensing: A Study of 101 Patients Implanted with Dual Chamber Defibrillators and Two Different Lead Systems . Modern dual chamber ICD systems are able to overcome various sensing problems. However, improvement of their performance is still required. The aim of this study was to assess the sensing function in 101 consecutive patients (84 men, 17 women; mean age 63 ± 12 years; mean follow-up 24 ± 4 months) implanted with dual chamber defibrillators and integrated (IB) or dedicated bipolar (DB) lead systems. Follow-up data were analyzed for the presence of ventricular oversensing. Oversensing occurred in 25 (25%) patients, significantly more frequent in patients implanted with IB compared to DB lead systems (21/52 vs 4/49, P = 0.0002). Patients with cardiomyopathies (CMs) were more prone to sensing malfunctions than patients with no CM (12/30 vs 13/71, P = 0.04). T wave oversensing (n = 14), respirophasic ventricular oversensing (n = 4), and P wave oversensing (n = 6) were the most common pitfalls of ventricular sensing. P wave oversensing was unique to the IB lead system. CT scans performed in these patients disclosed the position of the RV coil to be proximal to the tricuspid area. Four patients received inappropriate ICD shocks due to oversensing. In all but two patients who received lead revision, oversensing was resolved by noninvasive means. In conclusion: (1) ventricular oversensing is a common problem occurring in up to 25% of patients with dual chamber ICDs; (2) P wave oversensing is a ventricular sensing problem affecting function of 11% of dual chamber devices with IB lead systems; (3) IB leads are significantly more susceptible to T wave and P wave oversensing than DB leads; and (4) patients with cardiomyopathies are more prone to oversensing than patients with other heart diseases. (PACE 2003; 26[Pt. I]:65–70)  相似文献   
4.
5.
6.
7.
8.
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号