Access to good-quality health services is crucial for the improvement of many health outcomes, such as those targeted by the
Millennium Development Goals (MDGs) adopted by the international community in 2000. The health-related MDGs cannot be achieved
if vulnerable populations do not have access to skilled personnel and to other necessary inputs. This paper focuses on the
geographical dimension of access and on one of its critical determinants: the availability of qualified personnel. The objective
of this paper is to offer a better understanding of the determinants of geographical imbalances in the distribution of health
personnel, and to identify and assess the strategies developed to correct them. It reviews the recent literature on determinants,
barriers and the effects of strategies that attempted to correct geographical imbalances, with a focus on empirical studies
from developing and developed countries. An analysis of determinants of success and failures of strategies implemented, and
a summary of lessons learnt, is included. 相似文献
Background: Pulmonary concentrations of aminoglycosides administered intravenously are usually low in the infected lung parenchyma. Nebulization represents an alternative to increase pulmonary concentrations, although the obstruction of bronchioles by purulent plugs may impair lung deposition by decreasing lung aeration.
Methods: An experimental bronchopneumonia was induced in anesthetized piglets by inoculating lower lobes with a suspension of 106 cfu/ml Escherichia coli. After 24 h of mechanical ventilation, 7 animals received two intravenous injections of 15 mg/kg amikacin, and 11 animals received two nebulizations of 40 mg/kg amikacin at 24-h intervals. One hour following the second administration, animals were killed, and multiple lung specimens were sampled for assessing amikacin pulmonary concentrations and quantifying lung aeration on histologic sections.
Results: Thirty-eight percent of the nebulized amikacin (15 mg/kg) reached the tracheobronchial tree. Amikacin pulmonary concentrations were always higher after nebulization than after intravenous administration, decreased with the extension of parenchymal infection, and were significantly influenced by lung aeration: 197 +/- 165 versus 6 +/- 5 [mu]g/g in lung segments with focal bronchopneumonia (P = 0.03), 40 +/- 62 versus 5 +/- 3 [mu]g/g in lung segments with confluent bronchopneumonia (P = 0.001), 18 +/- 7 versus 7 +/- 4 [mu]g/g in lung segments with lung aeration of 30% or less, and 65 +/- 9 versus 2 +/- 3 [mu]g/g in lung segments with lung aeration of 50% or more. 相似文献
Summary We report a case of a male patient suffering from a severe hemorrhagic radiation proctitis which gradually ceased with hyperbaric oxygen. We discuss the mechanisms of chronic radiation injury and the effect of the hyperbaric oxygen. This therapy is proposed as an alternative to surgical intervention for this abnormality. 相似文献
Edrophonium, an anticholinesterase, exerts a biphasic effect on cardiovascular autonomic drive in humans (lower doses enhance; higher doses reduce). Twenty-five anesthetized, mechanically respired (10 breaths. min(-1), constant tidal volume) patients were given either saline (n = 10) or edrophonium (0.01-1.0 mg. kg(-1), n = 15) following surgery. ECG, radial arterial pressure, and respiratory rate were sampled at 250 Hz to obtain time series for consecutive R-R intervals (RRIs), and systolic (SBP) and diastolic blood pressure (DBP). A Wigner distribution was used for time frequency mapping of spectral powers at high (HFP, 0.15-0.5 Hz) and low (LFP, 0.0-0.05 Hz) frequency. Edrophonium produced a dose-dependent decrease in heart rate [baseline 66.8 +/- 1.9 (S.E.M.) beats per minute; maximum decrease to 55.8 +/- 1.4 beats per minute with 1.0 mg. kg(-1), P < 0.01]. HFP of the RRI increased at low doses (0.2-0.4 mg. kg(-1); maximum increase to 111.0 +/- 58.2% baseline; P < 0.01) but decreased (-49.5 +/- 35.5% baseline; P < 0.01) at higher (1.0 mg. kg(-1)) doses. Edrophonium had no effect on SBP and DBP. HFP of SBP decreased with increasing doses (maximal decrease to -26.2 +/- 7.5% baseline, P < 0.01, 1.0 mg. kg(-1)). LFP of SBP was also decreased (-46.3 +/- 10.9% baseline, P < 0.01, 1.0 mg. kg(-1)). Edrophonium may enhance (lower dose) or reduce (higher dose) cardiovascular autonomic drive in humans, as evidenced by the significant changes it evokes in HFP of the RRI (parasympathetic drive), and in the HFP and LFP of SBP (sympathetic drive). These observations may account for the modest autonomic side effects of edrophonium when this drug is used clinically. 相似文献
PURPOSE: The gum elastic bougie (GEB) has been in use for a long time and allows tracheal intubation in most cases of difficult direct laryngoscopy. Use of the GEB when anatomical landmarks of the upper airway are not recognizable has not been reported. We describe our experience of airway management with the GEB in cases of severe upper airway distortion. CLINICAL FEATURES: Four patients with severe respiratory distress caused by upper airway distortion secondary to various non-malignant causes were managed with the GEB. For these four patients, a rapid sequence induction of anesthesia was performed with a surgeon present during the procedure. The GEB was used as the initial intubating technique in all cases and allowed a rapid and successful tracheal intubation in spite of non-recognizable anatomical structures. The distal hold-up feeling after GEB insertion confirmed, in all cases, the correct intratracheal position of the GEB. CONCLUSION: The GEB can be a valuable tool in cases of difficult airway management caused by upper airway distortion. The lack of visualization of normal pharyngeal structures did not prevent the successful insertion of the GEB in the trachea in the four patients reported. 相似文献
OBJECTIVE: The aim of this study was to make a quantitative analysis of the changes in cranial and limb muscle activity from wakefulness to light and deep sleep stages and during rapid eye movement (REM) sleep of normal subjects. METHODS: Polysomnographic recordings were made of the sleep of 9 healthy human subjects, including electromyograms of the suprahyoid, temporalis and masseter cranial muscles and the anterior tibialis limb muscle. Quantitative assessments of EMG activity were carried out with root mean square (RMS) and frequency-spectral analysis (FSA) methods. RESULTS: From wakefulness to sleep, a significant reduction (-25.2 to -71.2%; P < 0.01) was observed in EMG activity (for both RMS and FSA) of the 3 cranial muscles using both methods of analysis. The EMG activity of suprahyoid muscle further decreased from non-REM to REM sleep (-17.8 to -43.0%; P < 0.01). In contrast, the EMG activity of the anterior tibialis muscle was only slightly reduced across sleep stages and did not further reduce during REM sleep. During REM sleep, all the 4 muscles maintained minimal activity. CONCLUSIONS: The maintenance of muscle activity during REM sleep suggests that a minimal level of activity is required to preserve physiological functions (e.g. airway patency, posture) related to homeostasis and bodily protection. SIGNIFICANCE: This study suggests that quantitative sleep EMG analysis is important for understanding the mechanisms of sleep-related movement disorders or when objective assessment of changes in EMG activity are needed for diagnostic purposes or for the assessment of drug efficiency. 相似文献